Design Guide - Pro Harmony Ranges
Page 4
... the temperature consistent throughout the cavity and allows for an extended period of heat so that accommodates even the largest meals effortlessly. 1.800.735.4328 | THERMADOR.COM 43 This mode is needed. Even the 48-inch model cleans both ovens simultaneously in standard 24-inch depth cabinets.
... the temperature consistent throughout the cavity and allows for an extended period of heat so that accommodates even the largest meals effortlessly. 1.800.735.4328 | THERMADOR.COM 43 This mode is needed. Even the 48-inch model cleans both ovens simultaneously in standard 24-inch depth cabinets.
Design Guide - Pro Harmony Ranges
Page 5
... 3/4" diam. flex line.) Supply Pressure: 6" min. MODEL PRD304GHu PRD364GDHu PRD366GHu PRD486GDHu REQuiRED ciRcuiT BREAkER 240/208V AC, 60 Hz 35 Amp 35 Amp 35 Amp 50 Amp ALL-GAS: Thermador Pro Harmony All-Gas Ranges are equipped with porcelain cooktop surface. MODEL PRG304GH PRL304GH PRG366GH .... Installation, electrical and gas connections, and grounding must be made with all -gas or dual-fuel configurations while the 48-inch model is utilized (PALPKITHC), conversion from the factory. A dedicated circuit breaker is required for further information. Dual-fuel models...
... 3/4" diam. flex line.) Supply Pressure: 6" min. MODEL PRD304GHu PRD364GDHu PRD366GHu PRD486GDHu REQuiRED ciRcuiT BREAkER 240/208V AC, 60 Hz 35 Amp 35 Amp 35 Amp 50 Amp ALL-GAS: Thermador Pro Harmony All-Gas Ranges are equipped with porcelain cooktop surface. MODEL PRG304GH PRL304GH PRG366GH .... Installation, electrical and gas connections, and grounding must be made with all -gas or dual-fuel configurations while the 48-inch model is utilized (PALPKITHC), conversion from the factory. A dedicated circuit breaker is required for further information. Dual-fuel models...
Design Guide - Pro Harmony Ranges
Page 6
...or 42" Pro Wall Hood 36" Griddle 36" Custom Insert w/optional blower 42" or 48" Island Hood w/optional 6 Burners blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert w/optional blower 54" Island Hood w/optional blower iMPORTANT VENTiLATiON NOTES: •... capacity. Alternate placement within the "Cutout and Range Dimensions" located on each side. • Due to the power supply with Thermador Pro Harmony Ranges. Downdraft ventilation should , at a minimum, equal the nominal width of the appliance cooking surface. WARRANTY Limited warranty...
...or 42" Pro Wall Hood 36" Griddle 36" Custom Insert w/optional blower 42" or 48" Island Hood w/optional 6 Burners blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert w/optional blower 54" Island Hood w/optional blower iMPORTANT VENTiLATiON NOTES: •... capacity. Alternate placement within the "Cutout and Range Dimensions" located on each side. • Due to the power supply with Thermador Pro Harmony Ranges. Downdraft ventilation should , at a minimum, equal the nominal width of the appliance cooking surface. WARRANTY Limited warranty...
Design Guide - Pro Harmony Ranges
Page 9
... PA36GtRH 36" Telescopic Rack PAGRIDDLE Griddle sits on grates over two burners PA12GcvRHc Griddle Cover PA12cHPBLK 12" Maple Chopping Block Pc24cHPBLK 24" Maple Chopping Block 48 Electronic oven control ensures precise heating - 36" units ship standard with Quick Clean Base™ - Every burner 18,000 BTU (NG) - Grill accessory - Simmer without...
... PA36GtRH 36" Telescopic Rack PAGRIDDLE Griddle sits on grates over two burners PA12GcvRHc Griddle Cover PA12cHPBLK 12" Maple Chopping Block Pc24cHPBLK 24" Maple Chopping Block 48 Electronic oven control ensures precise heating - 36" units ship standard with Quick Clean Base™ - Every burner 18,000 BTU (NG) - Grill accessory - Simmer without...
Design Guide - Pro Harmony Ranges
Page 13
... cast-aluminum griddle - Titanium surface non-stick, rust-proof cast-aluminum grill accessory - PRO HaRmOny® RanGES 48-InCH DUaL-FUEL model: PRD486GDHU PROFESSIOnaL PRD486GDHU Dual-Fuel Standard-Depth Range, Porcelain Cooktop Surface SPECIFICaTIOnS Total Number of simmer options from 375 BTU to 3,000 .../208V AC, 60 Hz 12,350 50 Amp Purchase Separately 499 PRD486GDHU PERFORmanCE - Simmer without flavor transfer - Pa48GLBH 9" Low Backguard (48-Inch Range) Pa48GHSH 22" High Backguard w/Shelf (48-Inch Range) PaLPKITHC LP Conversion Kit PWOKRInGHC Wok Ring PaGRIDDLE Griddle ...
... cast-aluminum griddle - Titanium surface non-stick, rust-proof cast-aluminum grill accessory - PRO HaRmOny® RanGES 48-InCH DUaL-FUEL model: PRD486GDHU PROFESSIOnaL PRD486GDHU Dual-Fuel Standard-Depth Range, Porcelain Cooktop Surface SPECIFICaTIOnS Total Number of simmer options from 375 BTU to 3,000 .../208V AC, 60 Hz 12,350 50 Amp Purchase Separately 499 PRD486GDHU PERFORmanCE - Simmer without flavor transfer - Pa48GLBH 9" Low Backguard (48-Inch Range) Pa48GHSH 22" High Backguard w/Shelf (48-Inch Range) PaLPKITHC LP Conversion Kit PWOKRInGHC Wok Ring PaGRIDDLE Griddle ...
Design Guide - Pro Harmony Ranges
Page 14
... components that creates a seamless look within standard cabinetry. BAckGuARD 48-inch Thermador Pro Harmony Ranges require an accessory backguard. PRO hARMONY® RANGES 48-iNch DuAL-FuEL Model: PRD486GDhu 48-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 24" 48" 41/4" 515/16" 103/4" 1811/16" 43/8" **...and are also a viable option, however the 27" depth of horizontal clearance behind the island trim. PRO hARMONY RANGES iNSTALLATiON OPTiONS Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that must be suitable ...
... components that creates a seamless look within standard cabinetry. BAckGuARD 48-inch Thermador Pro Harmony Ranges require an accessory backguard. PRO hARMONY® RANGES 48-iNch DuAL-FuEL Model: PRD486GDhu 48-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 24" 48" 41/4" 515/16" 103/4" 1811/16" 43/8" **...and are also a viable option, however the 27" depth of horizontal clearance behind the island trim. PRO hARMONY RANGES iNSTALLATiON OPTiONS Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that must be suitable ...
Installation Instructions
Page 3
... Massachusetts Installations: 1. VERIFY THAT THE ANTI-TIP DEVICE IS ENGAGED PER INSTALLATION INSTRUCTIONS. (NOTE: ANTI-TIP DEVICE IS REQUIRED ON ALL 30" AND 36" RANGES; 48" RANGES DO NOT REQUIRE AN ANTI-TIP DEVICE). WARNING • All Ranges can tip • Injury to light any appliance. • Do not touch any...
... Massachusetts Installations: 1. VERIFY THAT THE ANTI-TIP DEVICE IS ENGAGED PER INSTALLATION INSTRUCTIONS. (NOTE: ANTI-TIP DEVICE IS REQUIRED ON ALL 30" AND 36" RANGES; 48" RANGES DO NOT REQUIRE AN ANTI-TIP DEVICE). WARNING • All Ranges can tip • Injury to light any appliance. • Do not touch any...
Installation Instructions
Page 6
... or 42" Pro Wall Hood 36" 36" Custom Insert w/ optional blower 6 burners 42" or 48" Island Hood w/ optional blower 48" or 54" Pro Wall Hood** 48" 6 burners with griddle 48" Custom Insert w/ optional blower Important Notes: • It is recommended that exceeds the width of ...steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. Materials with Thermador Professional Ranges. • The HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are required. Step 2: Cabinet Preparation 1. English 4 A...
... or 42" Pro Wall Hood 36" 36" Custom Insert w/ optional blower 6 burners 42" or 48" Island Hood w/ optional blower 48" or 54" Pro Wall Hood** 48" 6 burners with griddle 48" Custom Insert w/ optional blower Important Notes: • It is recommended that exceeds the width of ...steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. Materials with Thermador Professional Ranges. • The HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are required. Step 2: Cabinet Preparation 1. English 4 A...
Installation Instructions
Page 7
... side wall. Δ As defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).*The range height is over 12", a Thermador Flush Island Trim may be used. Range Height with Leveling Legs fully retracted *36-3/4" Max. The level of Combustible Material 30" Range - 30..." 36" Range - 36" 48" Range - 48" 13" Max. } Cabinet Depth Range width 30", 36" or 48" 5" Min. if hood 18" contains combustible Min. to cooking surface (36" min. For Electrical and Gas Supply...
... side wall. Δ As defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).*The range height is over 12", a Thermador Flush Island Trim may be used. Range Height with Leveling Legs fully retracted *36-3/4" Max. The level of Combustible Material 30" Range - 30..." 36" Range - 36" 48" Range - 48" 13" Max. } Cabinet Depth Range width 30", 36" or 48" 5" Min. if hood 18" contains combustible Min. to cooking surface (36" min. For Electrical and Gas Supply...
Installation Instructions
Page 8
Installation must allow ample clearance for movement around the door when fully opened. English 6 * Refers to 44-7/8" from the back wall, behind the range when installed. Figure 2: Side View Note: With the oven door fully open, the top of the door extends to 30", 36" and 48" range models.
Installation must allow ample clearance for movement around the door when fully opened. English 6 * Refers to 44-7/8" from the back wall, behind the range when installed. Figure 2: Side View Note: With the oven door fully open, the top of the door extends to 30", 36" and 48" range models.
Installation Instructions
Page 9
Gas and Electric Supply Gas & Electrical Supply Locations for 30" and 36" Dual Fuel Ranges Gas & Electrical Supply Locations for 48" Dual Fuel Ranges 2-1/2" maximum protrusion from wall for gas or electrical supply Gas Supply Zone 4-3/8" Electrical Supply Zone 2-1/2" 4-3/8" 10-3/4" 48" 18-11/16" 5-15/16" Figure 3a: Gas & Electrical Supply Locations for Dual Fuel Ranges English 7
Gas and Electric Supply Gas & Electrical Supply Locations for 30" and 36" Dual Fuel Ranges Gas & Electrical Supply Locations for 48" Dual Fuel Ranges 2-1/2" maximum protrusion from wall for gas or electrical supply Gas Supply Zone 4-3/8" Electrical Supply Zone 2-1/2" 4-3/8" 10-3/4" 48" 18-11/16" 5-15/16" Figure 3a: Gas & Electrical Supply Locations for Dual Fuel Ranges English 7
Installation Instructions
Page 11
... doors, burner caps, front kick panel and oven racks 30" Range 350 lbs. 230 lbs. 190 lbs. 36" Range 370 lbs. 270 lbs. 220 lbs. 48" Range 500 lbs. 400 lbs. 320 lbs. THE FLOOR UNDER THE LEGS SHOULD BE PROTECTED BEFORE PUSHING THE UNIT INTO If the range is placed...
... doors, burner caps, front kick panel and oven racks 30" Range 350 lbs. 230 lbs. 190 lbs. 36" Range 370 lbs. 270 lbs. 220 lbs. 48" Range 500 lbs. 400 lbs. 320 lbs. THE FLOOR UNDER THE LEGS SHOULD BE PROTECTED BEFORE PUSHING THE UNIT INTO If the range is placed...
Installation Instructions
Page 13
This is due to the size and weight distribution of the 48" models. • Prepare holes at fastener locations as identified below: • For walls, wall studs, or floors composed of solid wood or metal, drill 1/8" pilot ...: 1. Mounting Anti-Tip Bracket The alternative floor mounted bracket shall be removed and reinstalled. Secure to floor or wall stud. 3. Figure 6: Anti-tip Bracket Note: 48" Ranges do not require the Anti-Tip Bracket. Place bracket on floor in position shown in Figure 7 (Bracket may be used in either corner of...
This is due to the size and weight distribution of the 48" models. • Prepare holes at fastener locations as identified below: • For walls, wall studs, or floors composed of solid wood or metal, drill 1/8" pilot ...: 1. Mounting Anti-Tip Bracket The alternative floor mounted bracket shall be removed and reinstalled. Secure to floor or wall stud. 3. Figure 6: Anti-tip Bracket Note: 48" Ranges do not require the Anti-Tip Bracket. Place bracket on floor in position shown in Figure 7 (Bracket may be used in either corner of...
Installation Instructions
Page 14
...valves. For installation of the appliance at high altitude, please consult your area's requirements before connecting the appliance. • The range is 48"; Obey all instructions in this kit for gas leaks. flex line) Supply Pressure: 6" min. The supply line must be converted for ...gas supply line connection is shipped from the gas supply piping system by a competent technician and in excess of Dual Fuel Ranges is Thermador Model PALPKITHC. Make certain the range matches the type of range. A qualified technician or installer must be in a location accessible from ...
...valves. For installation of the appliance at high altitude, please consult your area's requirements before connecting the appliance. • The range is 48"; Obey all instructions in this kit for gas leaks. flex line) Supply Pressure: 6" min. The supply line must be converted for ...gas supply line connection is shipped from the gas supply piping system by a competent technician and in excess of Dual Fuel Ranges is Thermador Model PALPKITHC. Make certain the range matches the type of range. A qualified technician or installer must be in a location accessible from ...
Installation Instructions
Page 15
... require 120 VAC to servicing appliance, always disconnect appliance electrical supply cord, if so equipped, from wall receptacle. MODEL TYPE 30" 36" 48" Chart B: Electrical Supply Circuit Requirements VOLTAGE CIRCUIT RATING FREQUENCY 240/208 VAC 240/208 VAC 240/208 VAC 35 Amps 35 Amps 50 Amps...unit by turning off the proper circuit breaker or disconnecting the proper fuse. English 13 A Figure 9: Location of Gas Supply Inlet Connection on 48" Ranges Figure 8: Location of shock hazard. If appliance is hard-wired to power supply, disconnect power to the power supply as described on...
... require 120 VAC to servicing appliance, always disconnect appliance electrical supply cord, if so equipped, from wall receptacle. MODEL TYPE 30" 36" 48" Chart B: Electrical Supply Circuit Requirements VOLTAGE CIRCUIT RATING FREQUENCY 240/208 VAC 240/208 VAC 240/208 VAC 35 Amps 35 Amps 50 Amps...unit by turning off the proper circuit breaker or disconnecting the proper fuse. English 13 A Figure 9: Location of Gas Supply Inlet Connection on 48" Ranges Figure 8: Location of shock hazard. If appliance is hard-wired to power supply, disconnect power to the power supply as described on...
Installation Instructions
Page 16
..., as applicable. • 4-CONDUCTOR CORD - • If the correct power supply circuit is not provided, it is the responsibility and obligation of Junction Box on 48" Ranges English 14 Recommended minimum free length of these codes or ordinances observe National Electrical Code ANSI/ NFPA No. 70 current issue. Refer to secure...
..., as applicable. • 4-CONDUCTOR CORD - • If the correct power supply circuit is not provided, it is the responsibility and obligation of Junction Box on 48" Ranges English 14 Recommended minimum free length of these codes or ordinances observe National Electrical Code ANSI/ NFPA No. 70 current issue. Refer to secure...
Installation Instructions
Page 19
... and Pan Shelf Included with Range N/A N/A N/A PA36GLBH PA48GLBH PA30GHSH PA36GHSH PA48GHSH Flush Island Trim PA30GITH Included with Range Included with great force. Model 30" 36" 48" Chart C: Backguard Kit Model Numbers 6" Std.
... and Pan Shelf Included with Range N/A N/A N/A PA36GLBH PA48GLBH PA30GHSH PA36GHSH PA48GHSH Flush Island Trim PA30GITH Included with Range Included with great force. Model 30" 36" 48" Chart C: Backguard Kit Model Numbers 6" Std.
User Manual
Page 2
..., CA 92649 Questions? 1-800-735-4328 www.thermador.com We look forward to hearing from you! Table of Contents About This Manual 1 How This Manual Is Organized 1 Introduction 1 Safety 2 Before You Begin 6 Before Using Your Range for the First Time6 Description 7 Model and Parts Identification - 48" Range 7 Model and Parts Identification - 36... Oven 31 Range Cleaning 32 Cleaning Recommendations 33 Do-It-Yourself Maintenance 37 Before Calling For Service 38 STATEMENT OF LIMITED PRODUCT WARRANTY 39 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave.
..., CA 92649 Questions? 1-800-735-4328 www.thermador.com We look forward to hearing from you! Table of Contents About This Manual 1 How This Manual Is Organized 1 Introduction 1 Safety 2 Before You Begin 6 Before Using Your Range for the First Time6 Description 7 Model and Parts Identification - 48" Range 7 Model and Parts Identification - 36... Oven 31 Range Cleaning 32 Cleaning Recommendations 33 Do-It-Yourself Maintenance 37 Before Calling For Service 38 STATEMENT OF LIMITED PRODUCT WARRANTY 39 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave.
User Manual
Page 3
...34.9 mb) from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your particular model range. The 48" model has an electric self-cleaning auxiliary oven with convection broil capability. All models are freestanding units available in your building. • ...Cooktop" and "Using the Oven" sections describe how to operate the appliance and how to ensure a long life for more information. The Thermador Professional® Ranges are certified for use with a proper backguard. Verify the type of the appliance for use with a backguard. Field ...
...34.9 mb) from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your particular model range. The 48" model has an electric self-cleaning auxiliary oven with convection broil capability. All models are freestanding units available in your building. • ...Cooktop" and "Using the Oven" sections describe how to operate the appliance and how to ensure a long life for more information. The Thermador Professional® Ranges are certified for use with a proper backguard. Verify the type of the appliance for use with a backguard. Field ...
User Manual
Page 4
.... 36" Dual-Fuel Models: 240/208 volts, 60 Hz., 35 Amp electrical circuit required for each line. 48" Dual-Fuel Models: 240/208 volts, 60 Hz., 50 Amp electrical circuit required for all Thermador Professional® Ranges. When using this range must be provided. CAUTION: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE...
.... 36" Dual-Fuel Models: 240/208 volts, 60 Hz., 35 Amp electrical circuit required for each line. 48" Dual-Fuel Models: 240/208 volts, 60 Hz., 50 Amp electrical circuit required for all Thermador Professional® Ranges. When using this range must be provided. CAUTION: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE...