To properly secure the anti-tip brackets for a stable installation, use the provided #8-18 x 11/4" PH truss HD screws and #12 flat washers with the anti-tip brackets provided. This depth will ensure that the anti-tip brackets engage the anti-...-tip brackets is critical to the back wall. Anti-Tip Bracket Hardware 2 Anti-tip brackets 12 #12 x 21/2" PH pan HD zinc screws 4 3/8"-16 x 33/4" wedge anchors 12 #12 flat washers 4 #8-18 x 11/4" PH truss HD screws 4 Nylon zip-it wall anchors. Site Preparation 14 Anti-Tip Bracket Installation To prevent the...
To properly secure the anti-tip brackets for a stable installation, use the provided #8-18 x 11/4" PH truss HD screws and #12 flat washers with the anti-tip brackets provided. This depth will ensure that the anti-tip brackets engage the anti-...-tip brackets is critical to the back wall. Anti-Tip Bracket Hardware 2 Anti-tip brackets 12 #12 x 21/2" PH pan HD zinc screws 4 3/8"-16 x 33/4" wedge anchors 12 #12 flat washers 4 #8-18 x 11/4" PH truss HD screws 4 Nylon zip-it wall anchors. Site Preparation 14 Anti-Tip Bracket Installation To prevent the...
Built-In Installation Guide
Page 15
Use the #12 x 21/2" PH pan HD zinc screws and #12 flat washers to secure the brackets in the wall studs or wall plate. CONCRETE FLOOR APPLICATIONS After properly locating ... recommended to cure. Use a carbide drill bit manufactured within ANSI B94.12-77. 2) Assemble the washer and nut flush with anchors. Use the #12 x 21/2" PH pan HD zinc screws and #12 flat washers to secure the brackets to the wall and use of core drills is flush with the surface...
Use the #12 x 21/2" PH pan HD zinc screws and #12 flat washers to secure the brackets in the wall studs or wall plate. CONCRETE FLOOR APPLICATIONS After properly locating ... recommended to cure. Use a carbide drill bit manufactured within ANSI B94.12-77. 2) Assemble the washer and nut flush with anchors. Use the #12 x 21/2" PH pan HD zinc screws and #12 flat washers to secure the brackets to the wall and use of core drills is flush with the surface...
Built-In Use & Care Guide
Page 40
...least 10,000 particles/ml 5,700,000/ml Lead at pH 6.5 53 0.15 mg/L ± 10% 0.153 mg/L Lead at pH 8.5 53 0.15 mg/L ± 10% 0.150 mg/L Mercury at pH 6.5 53 0.006 mg/L ± 10% 0.006 mg/L Mercury at pH 8.5 53 0.006 mg/L ± 10% 0.006 mg... of Lead, Mercury, Atrazine, Benzene, Carbofuran, 1,4dichlorobenzene, Lindane, Toxaphene, Turbidity, Cysts and Asbestos. Water Filtration System Performance Data 40 Sub-Zero Water Filtration System REPLACEMENT CARTRIDGE (4204490) Tested and certified by NSF International against NSF/ANSI Standard 53 for water leaving the system, as...
...least 10,000 particles/ml 5,700,000/ml Lead at pH 6.5 53 0.15 mg/L ± 10% 0.153 mg/L Lead at pH 8.5 53 0.15 mg/L ± 10% 0.150 mg/L Mercury at pH 6.5 53 0.006 mg/L ± 10% 0.006 mg/L Mercury at pH 8.5 53 0.006 mg/L ± 10% 0.006 mg... of Lead, Mercury, Atrazine, Benzene, Carbofuran, 1,4dichlorobenzene, Lindane, Toxaphene, Turbidity, Cysts and Asbestos. Water Filtration System Performance Data 40 Sub-Zero Water Filtration System REPLACEMENT CARTRIDGE (4204490) Tested and certified by NSF International against NSF/ANSI Standard 53 for water leaving the system, as...
BI-36RG Quick Reference Guide
Page 1
BI-36RG/S/TH Stainless Stainless Tubular BI-36RG/S/PH Stainless Stainless Pro INTERIOR FEATURES • Refrigerator 23.5 cu ft Capacity Air Purification System 4 Adjustable Glass Shelves 1 Stationary Glass Shelf 1 High-Humidity ... flip-up grille. Flip-up grille. • Informational freshness cards. Framed, overlay, flush inset and stainless steel design options are available through your Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. FEATURES • Electronic microprocessor constantly monitors entire unit...
BI-36RG/S/TH Stainless Stainless Tubular BI-36RG/S/PH Stainless Stainless Pro INTERIOR FEATURES • Refrigerator 23.5 cu ft Capacity Air Purification System 4 Adjustable Glass Shelves 1 Stationary Glass Shelf 1 High-Humidity ... flip-up grille. Flip-up grille. • Informational freshness cards. Framed, overlay, flush inset and stainless steel design options are available through your Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. FEATURES • Electronic microprocessor constantly monitors entire unit...
BI-36RG Energy Guide
Page 3
... this label before consumer purchase. Government Federal law prohibits removal of this model was not available at the time the range was published. Model BI-36RA/S/PH, BI-36RA/S/TH, BI-36RG/S/PH, BI-36RG/S/TH Capacity: 23.3 Cubic Feet Estimated Yearly Operating Cost $54 $36 $50 The estimated annual energy consumption of 10.65 cents per kWh...
... this label before consumer purchase. Government Federal law prohibits removal of this model was not available at the time the range was published. Model BI-36RA/S/PH, BI-36RA/S/TH, BI-36RG/S/PH, BI-36RG/S/TH Capacity: 23.3 Cubic Feet Estimated Yearly Operating Cost $54 $36 $50 The estimated annual energy consumption of 10.65 cents per kWh...
BI-36RG Energy Guide
Page 4
... most energy / Consommé le plus d'énergie Similar models compared 22.5 - 24.4 Modeles similaires volume in ft.3 / volume en pi3 comparés Model number BI-36RA/S/PH, Numéro du modèle BI-36RA/S/TH, BI-36RG/S/PH, BI-36RG/S/TH Removal of this label before first retail purchase is an offence (S.C. 1992, c.36).
... most energy / Consommé le plus d'énergie Similar models compared 22.5 - 24.4 Modeles similaires volume in ft.3 / volume en pi3 comparés Model number BI-36RA/S/PH, Numéro du modèle BI-36RA/S/TH, BI-36RG/S/PH, BI-36RG/S/TH Removal of this label before first retail purchase is an offence (S.C. 1992, c.36).