Sub-Zero Design Guide
Page 10
... DEPTH TOP VIEW IMPORTANT NOTE: If an 83" (2108) grille height is specified, the opening height must be decreased by 7/8" (22). If two units are installed side by 4" (102). If an 88" (2235) grille height is specified, the opening height increases by side, refer to pages 30-31 for dual standard... installations. 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Width BI-36R, BI-36RG and BI-36F BI-30U and BI-...
... DEPTH TOP VIEW IMPORTANT NOTE: If an 83" (2108) grille height is specified, the opening height must be decreased by 7/8" (22). If two units are installed side by 4" (102). If an 88" (2235) grille height is specified, the opening height increases by side, refer to pages 30-31 for dual standard... installations. 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Width BI-36R, BI-36RG and BI-36F BI-30U and BI-...
Sub-Zero Design Guide
Page 11
...shown in the illustrations. A saddle valve kit is achieved by removing the water filter cartridge. This is available through your authorized Sub-Zero dealer. Plumbing Requirements Water Supply Line 1/4" OD copper, braided stainless steel or PEX tubing Water Pressure 35-120 psi (2.4-8.3 bar... not recommended for detailed instructions. Refer to bypass mode. The water line must be set to the built-in installation guide packed with installation of operation. Built-In Refrigeration 11 subzero.com/specs Planning Information ELECTRICAL REQUIREMENTS For all times. A copper line ...
...shown in the illustrations. A saddle valve kit is achieved by removing the water filter cartridge. This is available through your authorized Sub-Zero dealer. Plumbing Requirements Water Supply Line 1/4" OD copper, braided stainless steel or PEX tubing Water Pressure 35-120 psi (2.4-8.3 bar... not recommended for detailed instructions. Refer to bypass mode. The water line must be set to the built-in installation guide packed with installation of operation. Built-In Refrigeration 11 subzero.com/specs Planning Information ELECTRICAL REQUIREMENTS For all times. A copper line ...
Sub-Zero Design Guide
Page 13
... optional extended handles may be provided around the panel to pages 30-31 for this section. Also, the edges of this application. IMPORTANT NOTE: When installing two units in a side-byside application, refer to ensure a proper fit. IMPORTANT NOTE: Do not cover a glass door with a sheet of shim material to build... edge must be backed up with a solid panel. If the panel is less than 1/4" (6). Be aware that rough opening dimensions are different for dual standard installations.
... optional extended handles may be provided around the panel to pages 30-31 for this section. Also, the edges of this application. IMPORTANT NOTE: When installing two units in a side-byside application, refer to ensure a proper fit. IMPORTANT NOTE: Do not cover a glass door with a sheet of shim material to build... edge must be backed up with a solid panel. If the panel is less than 1/4" (6). Be aware that rough opening dimensions are different for dual standard installations.
Sub-Zero Design Guide
Page 18
... can be adding panels and handles to give the unit a more seamless appearance that the application specified will affect panel sizes, rough opening dimensions and installation. The overlay design allows decorative panels to cover the door trim for a more custom look is to work with unique hardware for exact sizing and...
... can be adding panels and handles to give the unit a more seamless appearance that the application specified will affect panel sizes, rough opening dimensions and installation. The overlay design allows decorative panels to cover the door trim for a more custom look is to work with unique hardware for exact sizing and...
Sub-Zero Design Guide
Page 19
... PANEL SPACER PANEL BACKER PANEL 5/16" (8) min 1/8" (3) 3/4" (19) typical .10" (3) 1/4" (6) Panel assembly cross section. Dimensions for dual standard installations. Do not exceed overlay panel dimensions, as they will be exposed. IMPORTANT NOTE: When installing two units in a side-byside application, refer to pages 30-31 for the grille panel are different for... placement of the trim and a rear view of the three-panel assembly with critical dimensions, standard for this could cause damage to panels and the Sub-Zero unit.
... PANEL SPACER PANEL BACKER PANEL 5/16" (8) min 1/8" (3) 3/4" (19) typical .10" (3) 1/4" (6) Panel assembly cross section. Dimensions for dual standard installations. Do not exceed overlay panel dimensions, as they will be exposed. IMPORTANT NOTE: When installing two units in a side-byside application, refer to pages 30-31 for the grille panel are different for... placement of the trim and a rear view of the three-panel assembly with critical dimensions, standard for this could cause damage to panels and the Sub-Zero unit.
Sub-Zero Design Guide
Page 22
... (610) OPENING DEPTH 24" (610) OPENING DEPTH 26 3/16" (665) FLUSH INSET DEPTH TOP VIEW Standard installation. 23/16" (56) TOP VIEW 11/4" (32) Flush inset installation. IMPORTANT NOTE: The flush inset application is an overlay unit in ovens. The illustrations below show the difference between ...standard and flush inset installations. Stainless steel panels are available as sales accessories. The same model is 1/4" (6) higher than the standard opening dimensions for ...
... (610) OPENING DEPTH 24" (610) OPENING DEPTH 26 3/16" (665) FLUSH INSET DEPTH TOP VIEW Standard installation. 23/16" (56) TOP VIEW 11/4" (32) Flush inset installation. IMPORTANT NOTE: The flush inset application is an overlay unit in ovens. The illustrations below show the difference between ...standard and flush inset installations. Stainless steel panels are available as sales accessories. The same model is 1/4" (6) higher than the standard opening dimensions for ...
Sub-Zero Design Guide
Page 23
... by 4" (102). If an 88" (2235) grille height is specified, the height to pages 32-36 for dual flush inset installations. IMPORTANT NOTE: If an 83" (2108) grille height is specified, the height to cleat and flush inset height increases by side, refer to cleat and ...flush inset height must be decreased by 7/8" (22). Built-In Refrigeration 23 subzero.com/specs Built-In Models FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET...
... by 4" (102). If an 88" (2235) grille height is specified, the height to pages 32-36 for dual flush inset installations. IMPORTANT NOTE: If an 83" (2108) grille height is specified, the height to cleat and flush inset height increases by side, refer to cleat and ...flush inset height must be decreased by 7/8" (22). Built-In Refrigeration 23 subzero.com/specs Built-In Models FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET...
Sub-Zero Design Guide
Page 24
... of the overlay, spacer and backer panels of the window cut-out will be exposed when the doors are different for dual flush inset installations. IMPORTANT NOTE: When installing two units side by side in overlay models. Refer to the full-scale templates at the end of the decorative panels will be... a seamless appearance that rough opening as well as the sides and a portion of the back side of this could cause damage to panels and the Sub-Zero unit. Be aware that blends with adjacent cabinets.
... of the overlay, spacer and backer panels of the window cut-out will be exposed when the doors are different for dual flush inset installations. IMPORTANT NOTE: When installing two units side by side in overlay models. Refer to the full-scale templates at the end of the decorative panels will be... a seamless appearance that rough opening as well as the sides and a portion of the back side of this could cause damage to panels and the Sub-Zero unit. Be aware that blends with adjacent cabinets.
Sub-Zero Design Guide
Page 29
... panel, an accessory kit is required. When planning for side panel dimensions. Routing detail. Refer to achieve a pleasing fit. When installing a built-in model, you are also available through your authorized Sub-Zero dealer. 24" (610) FRONT OF SIDE PANEL 1" (25) 17/8" (48) ROUT TO 1/8" (3) 17/8"(48) 1" (25) 84" (2134) 1/8" (3) 1/2" (13) MAIN SIDE...
... panel, an accessory kit is required. When planning for side panel dimensions. Routing detail. Refer to achieve a pleasing fit. When installing a built-in model, you are also available through your authorized Sub-Zero dealer. 24" (610) FRONT OF SIDE PANEL 1" (25) 17/8" (48) ROUT TO 1/8" (3) 17/8"(48) 1" (25) 84" (2134) 1/8" (3) 1/2" (13) MAIN SIDE...
Sub-Zero Design Guide
Page 30
...width to your authorized Sub-Zero dealer. Refer to page 36 for information on page 42. Dual installations without a filler strip can be placed side by side in a flush inset application, refer to prevent condensation between two units in a dual installation. Dual Installation Panel Requirements MAX WEIGHT...two units with opposite hinges as shown in illustrations B and C require a filler strip. C A Illus. Refer to the full-scale template on dual installation kits. 75 lbs (34 kg) 50 lbs (23 kg) 26 lbs (12 kg) 1/4" (6) 5/8" (16) WITHOUT FILLER STRIP FILLER STRIP REQUIRED...
...width to your authorized Sub-Zero dealer. Refer to page 36 for information on page 42. Dual installations without a filler strip can be placed side by side in a flush inset application, refer to prevent condensation between two units in a dual installation. Dual Installation Panel Requirements MAX WEIGHT...two units with opposite hinges as shown in illustrations B and C require a filler strip. C A Illus. Refer to the full-scale template on dual installation kits. 75 lbs (34 kg) 50 lbs (23 kg) 26 lbs (12 kg) 1/4" (6) 5/8" (16) WITHOUT FILLER STRIP FILLER STRIP REQUIRED...
Sub-Zero Design Guide
Page 31
Built-In Refrigeration Dual Installation STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 31 subzero.com/specs 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models FRONT VIEW A 593/4" (1518) 653/4" (1670) 713/4" (1822) IMPORTANT NOTE: A dual installation kit will be required for this installation.
Built-In Refrigeration Dual Installation STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 31 subzero.com/specs 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models FRONT VIEW A 593/4" (1518) 653/4" (1670) 713/4" (1822) IMPORTANT NOTE: A dual installation kit will be required for this installation.
Sub-Zero Design Guide
Page 32
.... Refer to the dimensions of the panels to the full-scale template on dual installation kits. In this application a dual installation accessory kit is the only application that will also require a dual installation kit, available through your authorized Sub-Zero dealer. Dual Installation Panel Requirements MAX WEIGHT PER PANEL BI-36R, BI-36RG and BI-36F...
.... Refer to the dimensions of the panels to the full-scale template on dual installation kits. In this application a dual installation accessory kit is the only application that will also require a dual installation kit, available through your authorized Sub-Zero dealer. Dual Installation Panel Requirements MAX WEIGHT PER PANEL BI-36R, BI-36RG and BI-36F...
Sub-Zero Design Guide
Page 33
Built-In Refrigeration 33 subzero.com/specs Dual Installation FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET ... 30" (762) and 36" (914) Models Two 36" (914) Models A B 593/4" (1518) 621/4" (1581) 653/4" (1670) 681/4" (1734) 713/4" (1822) 741/4" (1886) IMPORTANT NOTE: A dual installation kit will be required for this installation. Dimensions assume a 3/4" (19) panel thickness.
Built-In Refrigeration 33 subzero.com/specs Dual Installation FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET ... 30" (762) and 36" (914) Models Two 36" (914) Models A B 593/4" (1518) 621/4" (1581) 653/4" (1670) 681/4" (1734) 713/4" (1822) 741/4" (1886) IMPORTANT NOTE: A dual installation kit will be required for this installation. Dimensions assume a 3/4" (19) panel thickness.
Sub-Zero Design Guide
Page 34
... to ensure the panels do not collide when closing. Illustrations A-F provide panel offsets and reveals for reference to the illustrations relating to panels and the Sub-Zero unit. All reveals are needed to achieve a proper fit and to be accomplished using two units with opposite hinges. D 5/16" (8) 5/32" (4) 1/2" (13) 3/32"...DUAL TRIM DOOR FLUSH INSET PANEL 5/16" (8) 1/2" (13) 5/8" (16) 5/16" (8) 1/8" (3) 1/4" (6) REVEAL Illus. C SIDE VIEW Illus. Built-In Refrigeration 34 Dual Installation FLUSH INSET PANEL OFFSETS When installing two built-in models side by 1/2" (13).
... to ensure the panels do not collide when closing. Illustrations A-F provide panel offsets and reveals for reference to the illustrations relating to panels and the Sub-Zero unit. All reveals are needed to achieve a proper fit and to be accomplished using two units with opposite hinges. D 5/16" (8) 5/32" (4) 1/2" (13) 3/32"...DUAL TRIM DOOR FLUSH INSET PANEL 5/16" (8) 1/2" (13) 5/8" (16) 5/16" (8) 1/8" (3) 1/4" (6) REVEAL Illus. C SIDE VIEW Illus. Built-In Refrigeration 34 Dual Installation FLUSH INSET PANEL OFFSETS When installing two built-in models side by 1/2" (13).
Sub-Zero Design Guide
Page 35
... wide grilles, refer to height dimensions. For an 88" (2235) finished height, add 4" (102) to page 36. Built-In Refrigeration 35 subzero.com/specs Dual Installation-Flush Inset Panels H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG BI-36R, BI-36RG and BI...
... wide grilles, refer to height dimensions. For an 88" (2235) finished height, add 4" (102) to page 36. Built-In Refrigeration 35 subzero.com/specs Dual Installation-Flush Inset Panels H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG BI-36R, BI-36RG and BI...
Sub-Zero Design Guide
Page 36
... minimum of the dual wide grille), heater, dual kickplate and mounting hardware. The overlay dual installation kit with each unit. Grille panel dimensions listed are available for proper installation of 2" (51) wide. This dual installation kit is not required if a custom filler strip is available for a standard 84" (2134...(235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) INSTALLATION WITH INDIVIDUAL GRILLES This kit is used. Refer to the panel specifications below for more information. Built-In Refrigeration 36 Dual...
... minimum of the dual wide grille), heater, dual kickplate and mounting hardware. The overlay dual installation kit with each unit. Grille panel dimensions listed are available for proper installation of 2" (51) wide. This dual installation kit is not required if a custom filler strip is available for a standard 84" (2134...(235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) INSTALLATION WITH INDIVIDUAL GRILLES This kit is used. Refer to the panel specifications below for more information. Built-In Refrigeration 36 Dual...
Sub-Zero Design Guide
Page 37
Built-In Refrigeration 37 subzero.com/specs Accessories These optional accessories are available through your authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. • Grilles for an 83" (2108) or 88"...lengths and the stud spacing of Wolf ovens and ranges. • Full-length standard and extended framed handles. • Stainless steel kickplate. • Dual installation kit with or without dual wide grille. • Retrofit kits for dispenser models. • Dozen egg container. • 90° door stop. •...
Built-In Refrigeration 37 subzero.com/specs Accessories These optional accessories are available through your authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. • Grilles for an 83" (2108) or 88"...lengths and the stud spacing of Wolf ovens and ranges. • Full-length standard and extended framed handles. • Stainless steel kickplate. • Dual installation kit with or without dual wide grille. • Retrofit kits for dispenser models. • Dozen egg container. • 90° door stop. •...
Sub-Zero Design Guide
Page 42
STANDARD TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Built-In Refrigeration 42 APPROX PROFILE OF STAINLESS STEEL WRAPPED DOOR AND HANDLE FILLER STRIP 11/4" (32) DOOR CLOSED Dual Installation-Standard FULL-SCALE TEMPLATE Typical framed, overlay or stainless steel dual installation with filler strip at maximum 110° door opening. Depending on panel thickness, a 90° door stop may be required.
STANDARD TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Built-In Refrigeration 42 APPROX PROFILE OF STAINLESS STEEL WRAPPED DOOR AND HANDLE FILLER STRIP 11/4" (32) DOOR CLOSED Dual Installation-Standard FULL-SCALE TEMPLATE Typical framed, overlay or stainless steel dual installation with filler strip at maximum 110° door opening. Depending on panel thickness, a 90° door stop may be required.
Sub-Zero Design Guide
Page 43
Built-In Refrigeration 43 subzero.com/specs PROFILE OF 3/4" (19) FLUSH INSET PANEL AND TUBULAR HANDLE FILLER STRIP 11/2" (38) 1/2" (13) DOOR CLOSED Dual Installation-Flush Inset FULL-SCALE TEMPLATE Typical flush inset dual installation with filler strip at maximum 110° door opening. FLUSH INSET TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Depending on panel thickness, a 90° door stop may be required.
Built-In Refrigeration 43 subzero.com/specs PROFILE OF 3/4" (19) FLUSH INSET PANEL AND TUBULAR HANDLE FILLER STRIP 11/2" (38) 1/2" (13) DOOR CLOSED Dual Installation-Flush Inset FULL-SCALE TEMPLATE Typical flush inset dual installation with filler strip at maximum 110° door opening. FLUSH INSET TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Depending on panel thickness, a 90° door stop may be required.
Sub-Zero Design Guide
Page 45
... food preservation-equal parts sculpted metal design statement and culinary secret weapon. tors allow independent control of storage conditions in the Sub-Zero PRO 48. Freshness finds unmistakable expression in refrigerator cabinet and drawer compartments. • Advanced water filtration system. • Slide...-K certified. Its vast interior, like its bold exterior, is available with or without a glass door and may be used freestanding or installed as a standard or flush built-in or freestanding. PRO 48 Refrigeration 45 subzero.com/specs PRO 48 Refrigeration. PRO 48 MODELS 48"...
... food preservation-equal parts sculpted metal design statement and culinary secret weapon. tors allow independent control of storage conditions in the Sub-Zero PRO 48. Freshness finds unmistakable expression in refrigerator cabinet and drawer compartments. • Advanced water filtration system. • Slide...-K certified. Its vast interior, like its bold exterior, is available with or without a glass door and may be used freestanding or installed as a standard or flush built-in or freestanding. PRO 48 Refrigeration 45 subzero.com/specs PRO 48 Refrigeration. PRO 48 MODELS 48"...