Instructions for Use
Page 2
..."System Menu 59 Adjusting the language - "*Language 69 Adjusting further settings - scope of delivery 6 Overview of the components 7 ADN D1 delegate unit 8 ADN C1 chairperson unit 9 ADN CU1 central unit 10 "Conference Manager" software 12 ADN PS power supply 13 The SDC CBL RJ-45 system cables 14 Structuring and controlling the conference system 15... Overview of the operating menu 45 Working with the operating menu 49 Adjusting the conference settings - Contents Contents Important safety instructions 3 The Sennheiser ADN conference system 5 Available system components -
..."System Menu 59 Adjusting the language - "*Language 69 Adjusting further settings - scope of delivery 6 Overview of the components 7 ADN D1 delegate unit 8 ADN C1 chairperson unit 9 ADN CU1 central unit 10 "Conference Manager" software 12 ADN PS power supply 13 The SDC CBL RJ-45 system cables 14 Structuring and controlling the conference system 15... Overview of the operating menu 45 Working with the operating menu 49 Adjusting the conference settings - Contents Contents Important safety instructions 3 The Sennheiser ADN conference system 5 Available system components -
Instructions for Use
Page 5
... volume to an authorized Sennheiser service partner. Manual This instruction manual is also available on the left is therefore obliged to constitute risk of fire or electric shock. Important safety instructions www Hazard warnings on the rear of the ADN CU1 central unit/ADN PS power supply The ...label shown on the Internet at www.sennheiser.com. 4 | ADN Digital Conference System In doing so, sound pressure exceeding 85 dB(A) can hear ringing or ...
... volume to an authorized Sennheiser service partner. Manual This instruction manual is also available on the left is therefore obliged to constitute risk of fire or electric shock. Important safety instructions www Hazard warnings on the rear of the ADN CU1 central unit/ADN PS power supply The ...label shown on the Internet at www.sennheiser.com. 4 | ADN Digital Conference System In doing so, sound pressure exceeding 85 dB(A) can hear ringing or ...
Instructions for Use
Page 7
...delivery The following ADN system components are available: ADN CU1 central unit 1 ADN CU1 central unit 1 Mains cable (EU, UK or US version), length 1.8 m 1 Quick guide 1 "Safety information" supplement 1 DVD-ROM (including, among other things, the "Conference Manager" software, the "ADN Cable Calculator" ...as PDF) ADN PS power supply 1 ADN PS power supply with premounted rack mount "ears" 1 Mains cable (EU, UK or US version), length 1.8 m 1 Quick guide 1 "Safety information" supplement ADN D1delegate unit 1 ADN D1 delegate unit 1 Quick guide ADN C1 chairman unit 1 ADN C1 chairperson unit...
...delivery The following ADN system components are available: ADN CU1 central unit 1 ADN CU1 central unit 1 Mains cable (EU, UK or US version), length 1.8 m 1 Quick guide 1 "Safety information" supplement 1 DVD-ROM (including, among other things, the "Conference Manager" software, the "ADN Cable Calculator" ...as PDF) ADN PS power supply 1 ADN PS power supply with premounted rack mount "ears" 1 Mains cable (EU, UK or US version), length 1.8 m 1 Quick guide 1 "Safety information" supplement ADN D1delegate unit 1 ADN D1 delegate unit 1 Quick guide ADN C1 chairman unit 1 ADN C1 chairperson unit...
Instructions for Use
Page 8
...for audio recording of conferences (optional) • REC ADN CU1 "Conference Manager" software Conferences with standard cabling a max. of 400 participants ADN PS ADN PS max. 15 ADN PS max. 400 ADN D1/ADN C1 max. 40 ADN D1/ADN C1 per ADN PS with redundant ring cabling a max. can be run... to a max. Overview of the components Overview of the components For conferencing, you require: • 1 ADN CU1 central unit • ADN D1 delegate units • ADN C1 chairperson units (optional, for granting speaking privileges, a maximum of 10 chairperson units can be used in redundant ...
...for audio recording of conferences (optional) • REC ADN CU1 "Conference Manager" software Conferences with standard cabling a max. of 400 participants ADN PS ADN PS max. 15 ADN PS max. 400 ADN D1/ADN C1 max. 40 ADN D1/ADN C1 per ADN PS with redundant ring cabling a max. can be run... to a max. Overview of the components Overview of the components For conferencing, you require: • 1 ADN CU1 central unit • ADN D1 delegate units • ADN C1 chairperson units (optional, for granting speaking privileges, a maximum of 10 chairperson units can be used in redundant ...
Instructions for Use
Page 11
... 45) for connec- Overview of conference units 0 VGA monitor output A USB socket (2x) B Network socket (RJ 45) C Fans D Mains socket E Hazard warnings F Type plate 10 | ADN Digital Conference System AUDIO -- tion of conference units 9 PORT I 2x 52.8V 1.75A 6 7 89 @AB E C F 100-240V~ 50/60Hz 240W D A Front view 1 On/off switch... panel 4 Jog dial 5 ESC key (Escape) 15 B Rear view 6 IN audio input 7 OUT audio output 8 PORT II socket (RJ 45) for connection of the components ADN CU1 central unit 1 2 3 45 ESC IN --
... 45) for connec- Overview of conference units 0 VGA monitor output A USB socket (2x) B Network socket (RJ 45) C Fans D Mains socket E Hazard warnings F Type plate 10 | ADN Digital Conference System AUDIO -- tion of conference units 9 PORT I 2x 52.8V 1.75A 6 7 89 @AB E C F 100-240V~ 50/60Hz 240W D A Front view 1 On/off switch... panel 4 Jog dial 5 ESC key (Escape) 15 B Rear view 6 IN audio input 7 OUT audio output 8 PORT II socket (RJ 45) for connection of the components ADN CU1 central unit 1 2 3 45 ESC IN --
Instructions for Use
Page 12
... is deactivated Lock mode of the central unit is not correctly connected to the ADN CU1 central unit (see page 59). L Cable fault icon Icon appears when a conference unit is activated ADN Digital Conference System | 11 Icon appears when there is still written to the mass...K Structural change icon Icon appears when, since the last initialization, a malfunction/change (see page 77). Overview of the components Overview of the ADN CU1 display panel After switch-on, the central unit's display shows progress bars (for the booting routine "Booting" and the self test "Selftest") and...
... is deactivated Lock mode of the central unit is not correctly connected to the ADN CU1 central unit (see page 59). L Cable fault icon Icon appears when a conference unit is activated ADN Digital Conference System | 11 Icon appears when there is still written to the mass...K Structural change icon Icon appears when, since the last initialization, a malfunction/change (see page 77). Overview of the components Overview of the ADN CU1 display panel After switch-on, the central unit's display shows progress bars (for the booting routine "Booting" and the self test "Selftest") and...
Instructions for Use
Page 13
Information on the software can be found in the chapter "Using the "Conference Manager" software" on page 80. 12 | ADN Digital Conference System Overview of the components "Conference Manager" software The "Conference Manager" software allows you to configure and control the entire conference from a Windows PC or directly from the ADN CU1 central unit.
Information on the software can be found in the chapter "Using the "Conference Manager" software" on page 80. 12 | ADN Digital Conference System Overview of the components "Conference Manager" software The "Conference Manager" software allows you to configure and control the entire conference from a Windows PC or directly from the ADN CU1 central unit.
Instructions for Use
Page 14
... are connected in redundant ring topology via outputs 1 and 2 flashing Error in a cable string; tion of conference units 7 PORT I socket - Overview of the components ADN PS power supply 1 2 3 4 5 1 ADN PS PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I & PORT II: max. 5.25A sum 67 8 90 A D B E 100 - 240V... on - output 2 (RJ 45) for connection of conference units < DATA CU/PS input socket (RJ 45) for connection of ADN CU1 central unit or ADN PS power supply A DATA PS output socket (RJ 45) for connection of conference units 9 PORT II socket - Not used, switched off...
... are connected in redundant ring topology via outputs 1 and 2 flashing Error in a cable string; tion of conference units 7 PORT I socket - Overview of the components ADN PS power supply 1 2 3 4 5 1 ADN PS PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I & PORT II: max. 5.25A sum 67 8 90 A D B E 100 - 240V... on - output 2 (RJ 45) for connection of conference units < DATA CU/PS input socket (RJ 45) for connection of ADN CU1 central unit or ADN PS power supply A DATA PS output socket (RJ 45) for connection of conference units 9 PORT II socket - Not used, switched off...
Instructions for Use
Page 16
... systems comprising only an ADN CU1 central unit - 30-40 conference units connected in simple strings • large conference systems comprising an ADN CU1 central unit and a max. The voltage supplied depends on the cable lengths. ADN D1 delegate units and ADN C1 chairperson units can be ...that all conference units are supplied with up to 10 max. ADN Digital Conference System | 15...
... systems comprising only an ADN CU1 central unit - 30-40 conference units connected in simple strings • large conference systems comprising an ADN CU1 central unit and a max. The voltage supplied depends on the cable lengths. ADN D1 delegate units and ADN C1 chairperson units can be ...that all conference units are supplied with up to 10 max. ADN Digital Conference System | 15...
Instructions for Use
Page 17
Structuring and controlling the conference system Small conference system with simple cabling For small conference systems with approx. 30-40 conference units, you require one ADN CU1 central unit for controlling the conference. ADN CU1 PORT II PORT I max. 40 ADN D1/ADN C1 ADN CU1 max. 80 m 52.8 V 1 approx. 2 approx. 3 2-5 m 2-5 m ... 20 >35 V 16 | ADN Digital Conference System The conference units are interconnected in two cable strings which are directly connected to the central unit.
Structuring and controlling the conference system Small conference system with simple cabling For small conference systems with approx. 30-40 conference units, you require one ADN CU1 central unit for controlling the conference. ADN CU1 PORT II PORT I max. 40 ADN D1/ADN C1 ADN CU1 max. 80 m 52.8 V 1 approx. 2 approx. 3 2-5 m 2-5 m ... 20 >35 V 16 | ADN Digital Conference System The conference units are interconnected in two cable strings which are directly connected to the central unit.
Instructions for Use
Page 18
... for powering the conference units. The conference units are interconnected in cable strings and up to each ADN PS power supply. ADN CU1 ADN PS (max. 15) PORT I/II PORT I 1 PORT I 2 PORT II PORT 2 II 1 max. 70 ADN D1/ADN C1 ADN CU1 ADN PS max. 80 m max. 80 m 52.8 V 1 2 3 approx. Structuring and controlling the conference system Large conference system...
... for powering the conference units. The conference units are interconnected in cable strings and up to each ADN PS power supply. ADN CU1 ADN PS (max. 15) PORT I/II PORT I 1 PORT I 2 PORT II PORT 2 II 1 max. 70 ADN D1/ADN C1 ADN CU1 ADN PS max. 80 m max. 80 m 52.8 V 1 2 3 approx. Structuring and controlling the conference system Large conference system...
Instructions for Use
Page 19
... power supply, you can be manipulated, all other conference units of the cable ring will continue to function reliably. ADN CU1 ADN PS (max. 15) PORT I/II PORT I 1 PORT I 2 PORT II 2 PORT II 1 max. 40 ADN D1/ADN C1 ADN CU1 ADN PS max. 80 m 1 2 3 max. 80 m ca. 2-5 m ca. 2-5 m 52.8 V ...... 20 >35 V When connecting the conference units to each ADN PS power supply. The conference units are interconnected in rings and two rings can mix...
... power supply, you can be manipulated, all other conference units of the cable ring will continue to function reliably. ADN CU1 ADN PS (max. 15) PORT I/II PORT I 1 PORT I 2 PORT II 2 PORT II 1 max. 40 ADN D1/ADN C1 ADN CU1 ADN PS max. 80 m 1 2 3 max. 80 m ca. 2-5 m ca. 2-5 m 52.8 V ...... 20 >35 V When connecting the conference units to each ADN PS power supply. The conference units are interconnected in rings and two rings can mix...
Instructions for Use
Page 20
...on a USB mass storage device, you can monitor and control all channels of the central unit or the "Conference Manager" software. ADN CU1 Conference Manager software Configuring and controlling the conference system For configuring the conference system, you can use the operating menu of the conference... can either use the recording function of the ADN CU1 central unit, which saves the floor channel and all functions of the "ADN Cable Calculator" software, refer to page 20. The software is available from the "Product Downloads" area on the product page at www.sennheiser.com.
...on a USB mass storage device, you can monitor and control all channels of the central unit or the "Conference Manager" software. ADN CU1 Conference Manager software Configuring and controlling the conference system For configuring the conference system, you can use the operating menu of the conference... can either use the recording function of the ADN CU1 central unit, which saves the floor channel and all functions of the "ADN Cable Calculator" software, refer to page 20. The software is available from the "Product Downloads" area on the product page at www.sennheiser.com.
Instructions for Use
Page 24
Ensure sufficient ventilation; Avoid circuit overloading. ADN Digital Conference System | 23 When installing the product in the specifications (see page 155). This can dissipate. ̈ When connecting to the mains power ...̈ Place the central unit on e.g. Putting the conference system into operation Putting the conference system into operation Preparing the ADN CU1 central unit for a duct or vent space of 1 U above the ADN CU1 central unit to ensure that the ambient temperature within the rack may drastically increase, • high mechanical loading may accumulate...
Ensure sufficient ventilation; Avoid circuit overloading. ADN Digital Conference System | 23 When installing the product in the specifications (see page 155). This can dissipate. ̈ When connecting to the mains power ...̈ Place the central unit on e.g. Putting the conference system into operation Putting the conference system into operation Preparing the ADN CU1 central unit for a duct or vent space of 1 U above the ADN CU1 central unit to ensure that the ambient temperature within the rack may drastically increase, • high mechanical loading may accumulate...
Instructions for Use
Page 25
... the mains power supply. ̈ Only use multi-outlet power strips or extension cables with protective ground contacts. ̈ Only use mains cables with e.g. The ADN CU1 central unit is now ready for connecting the product to the sides of the central unit can damage the product. ̈ Use the mains cable...
... the mains power supply. ̈ Only use multi-outlet power strips or extension cables with protective ground contacts. ̈ Only use mains cables with e.g. The ADN CU1 central unit is now ready for connecting the product to the sides of the central unit can damage the product. ̈ Use the mains cable...
Instructions for Use
Page 30
...PORT I and PORT II. A total of 400 conference units can be damaged due to an unsuitable power supply. ̈ Only connect ADN C1 and ADN D1 conference units to ensure that all conference units connected are supplied with RJ 45 plugs (e.g. Putting the conference system into operation Setting ... damage due to 10 max.). If you connect standard network devices with sufficient voltage (see page 19). ̈ Place the ADN CU1 central unit and, if necessary, the ADN PS power supplies in the electrical equipment room. ̈ Place the conference units at the corresponding seats. ̈ Put out...
...PORT I and PORT II. A total of 400 conference units can be damaged due to an unsuitable power supply. ̈ Only connect ADN C1 and ADN D1 conference units to ensure that all conference units connected are supplied with RJ 45 plugs (e.g. Putting the conference system into operation Setting ... damage due to 10 max.). If you connect standard network devices with sufficient voltage (see page 19). ̈ Place the ADN CU1 central unit and, if necessary, the ADN PS power supplies in the electrical equipment room. ̈ Place the conference units at the corresponding seats. ̈ Put out...
Instructions for Use
Page 31
...the conference system into operation Setting up a small conference system with only the central unit For a small conference system, you do not require ADN PS power supplies. ADN CU1 ADN D1/ADN C1 IN -- If necessary, repeat these steps for additional conference units. ̈ If necessary, repeat all steps for a second cable string. ... 52.8V 1.75A 89 PORT II PORT I 100-240V~ 50/60Hz 240W IN OUT µ¸ IN OUT IN OUT ADN CU1 PORT II PORT I socket 9 of the ADN CU1 central unit to the IN socket µ of the first conference unit. ̈ Use a system cable to connect the OUT...
...the conference system into operation Setting up a small conference system with only the central unit For a small conference system, you do not require ADN PS power supplies. ADN CU1 ADN D1/ADN C1 IN -- If necessary, repeat these steps for additional conference units. ̈ If necessary, repeat all steps for a second cable string. ... 52.8V 1.75A 89 PORT II PORT I 100-240V~ 50/60Hz 240W IN OUT µ¸ IN OUT IN OUT ADN CU1 PORT II PORT I socket 9 of the ADN CU1 central unit to the IN socket µ of the first conference unit. ̈ Use a system cable to connect the OUT...
Instructions for Use
Page 32
...240V~ 50/60Hz 240W PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I socket 9 of the ADN CU1 central unit to the DATA CU/PS input socket < of the first ADN PS power supply (shorter cables increase the operational reliability, the maximum length allowed is 80 m). ̈ Use a system.... 5.25A sum DATA CU/PS PS of the second ADN PS power supply. ̈ Repeat these steps for the remaining ADN PS power supplies. A max. Putting the conference system into operation Connecting ADN PS power supplies to the ADN CU1 central unit For conference systems comprising more than 40 conference units...
...240V~ 50/60Hz 240W PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I socket 9 of the ADN CU1 central unit to the DATA CU/PS input socket < of the first ADN PS power supply (shorter cables increase the operational reliability, the maximum length allowed is 80 m). ̈ Use a system.... 5.25A sum DATA CU/PS PS of the second ADN PS power supply. ̈ Repeat these steps for the remaining ADN PS power supplies. A max. Putting the conference system into operation Connecting ADN PS power supplies to the ADN CU1 central unit For conference systems comprising more than 40 conference units...
Instructions for Use
Page 33
... conference unit. ̈ Use a system cable to connect the OUT socket ¸ of the first conference unit to the IN socket µ of ADN PS power supplies to the ADN CU1 central unit (see page 31). ̈ Use a system cable to connect the PORT I PORT II 12 12 100 - 240V 50/60Hz 385W... IN OUT µ¸ IN OUT IN OUT 32 | ADN Digital Conference System ADN PS ADN D1/ADN C1 PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I & PORT II...
... conference unit. ̈ Use a system cable to connect the OUT socket ¸ of the first conference unit to the IN socket µ of ADN PS power supplies to the ADN CU1 central unit (see page 31). ̈ Use a system cable to connect the PORT I PORT II 12 12 100 - 240V 50/60Hz 385W... IN OUT µ¸ IN OUT IN OUT 32 | ADN Digital Conference System ADN PS ADN D1/ADN C1 PORT I 1 2 PORT II 1 2 DATA CU/PS PS PORT I & PORT II...
Instructions for Use
Page 34
... approx. 15-20 conference units per cable string due to the voltage drop on the cable string (see page 15). ADN Digital Conference System | 33 Putting the conference system into operation ADN CU1 ADN PS ADN PS OUT IN ... 20 OUT IN 1 OUT IN ... 20 OUT IN 1 OUT IN ... 20 OUT IN 1 OUT IN ... 20...
... approx. 15-20 conference units per cable string due to the voltage drop on the cable string (see page 15). ADN Digital Conference System | 33 Putting the conference system into operation ADN CU1 ADN PS ADN PS OUT IN ... 20 OUT IN 1 OUT IN ... 20 OUT IN 1 OUT IN ... 20 OUT IN 1 OUT IN ... 20...