Savvio 15K.3 SAS Product Manual
Page 1
Product Manual Savvio® 15K.3 SAS Standard Models ST9300653SS ST9146853SS Self-Encrypting Drive Models ST9300553SS ST9146753SS SED FIPS140-2 Models ST9300453SS ST9146653SS 100629381 Rev. D January 2012
Product Manual Savvio® 15K.3 SAS Standard Models ST9300653SS ST9146853SS Self-Encrypting Drive Models ST9300553SS ST9146753SS SED FIPS140-2 Models ST9300453SS ST9146653SS 100629381 Rev. D January 2012
Savvio 15K.3 SAS Product Manual
Page 3
D i Contents 1.0 Seagate Technology support services 1 2.0 Scope 2 3.0 Applicable standards and reference documentation 3 3.1 Standards 3 3.1.1 Electromagnetic compatibility 3 3.1.2 Electromagnetic compliance 4 3.1.3 European Union Restriction of Hazardous Substances (RoHS 5 3.1.4 China Restriction of Hazardous ... power management 22 7.1.1 PowerChoice reporting methods 23 7.2 AC power requirements 23 7.3 DC power requirements 23 7.3.1 Conducted noise immunity 26 7.3.2 Power sequencing 26 7.3.3 Current profiles 27 Savvio 15K.3 SAS Product Manual, Rev.
D i Contents 1.0 Seagate Technology support services 1 2.0 Scope 2 3.0 Applicable standards and reference documentation 3 3.1 Standards 3 3.1.1 Electromagnetic compatibility 3 3.1.2 Electromagnetic compliance 4 3.1.3 European Union Restriction of Hazardous Substances (RoHS 5 3.1.4 China Restriction of Hazardous ... power management 22 7.1.1 PowerChoice reporting methods 23 7.2 AC power requirements 23 7.3 DC power requirements 23 7.3.1 Conducted noise immunity 26 7.3.2 Power sequencing 26 7.3.3 Current profiles 27 Savvio 15K.3 SAS Product Manual, Rev.
Savvio 15K.3 SAS Product Manual
Page 4
...RevertSP 40 10.0 Defect and error management 41 10.1 Drive internal defects/errors 41 10.2 Drive error recovery procedures 41 10.3 SAS system errors 42 10.4 Background Media Scan 43 10.5 Media Pre-Scan 43 10.6 Deferred Auto-Reallocation 43 10.7 Idle Read... Task management responses 49 12.2 Dual port support 50 12.3 SCSI commands supported 50 12.3.1 Inquiry data 54 12.3.2 Mode Sense data 54 ii Savvio 15K.3 SAS Product Manual, Rev. D 7.4 Power dissipation 29 7.5 Environmental limits 31 7.5.1 Temperature 31 7.5.2 Relative humidity 31 7.5.3 Effective altitude (sea level 32...
...RevertSP 40 10.0 Defect and error management 41 10.1 Drive internal defects/errors 41 10.2 Drive error recovery procedures 41 10.3 SAS system errors 42 10.4 Background Media Scan 43 10.5 Media Pre-Scan 43 10.6 Deferred Auto-Reallocation 43 10.7 Idle Read... Task management responses 49 12.2 Dual port support 50 12.3 SCSI commands supported 50 12.3.1 Inquiry data 54 12.3.2 Mode Sense data 54 ii Savvio 15K.3 SAS Product Manual, Rev. D 7.4 Power dissipation 29 7.5 Environmental limits 31 7.5.1 Temperature 31 7.5.2 Relative humidity 31 7.5.3 Effective altitude (sea level 32...
Savvio 15K.3 SAS Product Manual
Page 5
D iii 12.4 Miscellaneous operating features and conditions 58 12.4.1 SAS physical interface 59 12.4.2 Physical characteristics 62 12.4.3 Connector requirements 62 12.4.4 Electrical description 62 12.4.5 Pin descriptions 62 12.4.6 SAS transmitters and receivers 63 12.4.7 Power 63 12.5 Signal characteristics 63 12.5.1 Ready LED Out 63 12.5.2 Differential signals 64 12.6 SAS-2 Specification compliance 64 12.7 Additional information 64 Savvio 15K.3 SAS Product Manual, Rev.
D iii 12.4 Miscellaneous operating features and conditions 58 12.4.1 SAS physical interface 59 12.4.2 Physical characteristics 62 12.4.3 Connector requirements 62 12.4.4 Electrical description 62 12.4.5 Pin descriptions 62 12.4.6 SAS transmitters and receivers 63 12.4.7 Power 63 12.5 Signal characteristics 63 12.5.1 Ready LED Out 63 12.5.2 Differential signals 64 12.6 SAS-2 Specification compliance 64 12.7 Additional information 64 Savvio 15K.3 SAS Product Manual, Rev.
Savvio 15K.3 SAS Product Manual
Page 7
.... Figure 8. List of FIPS tamper evidence labels/seals 37 Physical interface 46 Air flow 47 Physical interface 59 SAS device plug dimensions 60 SAS device plug dimensions (detail 61 SAS transmitters and receivers 63 Savvio 15K.3 SAS Product Manual, Rev. input/output operations per second 30 Location of the HDA temperature check point 31 Recommended mounting...
.... Figure 8. List of FIPS tamper evidence labels/seals 37 Physical interface 46 Air flow 47 Physical interface 59 SAS device plug dimensions 60 SAS device plug dimensions (detail 61 SAS transmitters and receivers 63 Savvio 15K.3 SAS Product Manual, Rev. input/output operations per second 30 Location of the HDA temperature check point 31 Recommended mounting...
Savvio 15K.3 SAS Product Manual
Page 9
... Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance For information regarding Data Recovery Services, visit http://www.i365.com For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system For Seagate reseller portal, visit http://spp.seagate.com Savvio 15K.3 SAS Product Manual, Rev.
... Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance For information regarding Data Recovery Services, visit http://www.i365.com For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system For Seagate reseller portal, visit http://spp.seagate.com Savvio 15K.3 SAS Product Manual, Rev.
Savvio 15K.3 SAS Product Manual
Page 10
...this and other forms of Data at Rest" based on the standards defined by the Trusted Computing Group (see Section 8.0 on page 36. 2 Savvio 15K.3 SAS Product Manual, Rev. The Self-Encrypting Drive Reference Manual, part number 100515636, describes the interface, general operation, and security features available on FIPS 140... (SED) No Yes Yes No Yes Yes FIPS 140-2 Level 2 No No Yes No No Yes Note. 2.0 Scope This manual describes Seagate Technology® LLC, Savvio® 15K.3 SAS (Serial Attached SCSI) disk drives. For more information on Self-Encrypting Drive models.
...this and other forms of Data at Rest" based on the standards defined by the Trusted Computing Group (see Section 8.0 on page 36. 2 Savvio 15K.3 SAS Product Manual, Rev. The Self-Encrypting Drive Reference Manual, part number 100515636, describes the interface, general operation, and security features available on FIPS 140... (SED) No Yes Yes No Yes Yes FIPS 140-2 Level 2 No No Yes No No Yes Note. 2.0 Scope This manual describes Seagate Technology® LLC, Savvio® 15K.3 SAS (Serial Attached SCSI) disk drives. For more information on Self-Encrypting Drive models.
Savvio 15K.3 SAS Product Manual
Page 11
...as a subassembly and is the responsibility of those integrating the drive within their systems to perform those tests required and design their system. Savvio 15K.3 SAS Product Manual, Rev. It is not subject to the system does not adversely affect the performance of the drive. See Tables 2 ... to use. however, it is designed for optimum performance and compliance with additional vendor-unique features as noted in this manual and the Seagate SAS Interface Manual, part number 100293071. Shielded I /O cables are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1...
...as a subassembly and is the responsibility of those integrating the drive within their systems to perform those tests required and design their system. Savvio 15K.3 SAS Product Manual, Rev. It is not subject to the system does not adversely affect the performance of the drive. See Tables 2 ... to use. however, it is designed for optimum performance and compliance with additional vendor-unique features as noted in this manual and the Seagate SAS Interface Manual, part number 100293071. Shielded I /O cables are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1...
Savvio 15K.3 SAS Product Manual
Page 12
...Australia/New Zealand Standard AS/NZ CISPR22 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Standards, Metrology, and Inspection (BSMI). 4 Savvio 15K.3 SAS Product Manual, Rev. Korean KCC If these drives have the Korean Communications Commission (KCC) logo, they comply with KN22, KN 24, and... EMC compliance and provide the appropriate marking for CE Marking and C-Tick Marking. Taiwanese BSMI If this Seagate model complies with the directives/standards, we cannot guarantee that all systems will comply. D 3.1.2 Electromagnetic compliance...
...Australia/New Zealand Standard AS/NZ CISPR22 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Standards, Metrology, and Inspection (BSMI). 4 Savvio 15K.3 SAS Product Manual, Rev. Korean KCC If these drives have the Korean Communications Commission (KCC) logo, they comply with KN22, KN 24, and... EMC compliance and provide the appropriate marking for CE Marking and C-Tick Marking. Taiwanese BSMI If this Seagate model complies with the directives/standards, we cannot guarantee that all systems will comply. D 3.1.2 Electromagnetic compliance...
Savvio 15K.3 SAS Product Manual
Page 13
...suppliers document their compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. Seagate also has internal systems in place to ensure that restricted substances are not utilized in electronic products effective July 2006... procured from external suppliers. "X RoHS MCV Savvio 15K.3 SAS Product Manual, Rev. A number of 20 years. These systems include standard operating procedures that ensure that all parts and materials for the disk drives documented in Seagate products are complied with. 3.1.4 China Restriction ...
...suppliers document their compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. Seagate also has internal systems in place to ensure that restricted substances are not utilized in electronic products effective July 2006... procured from external suppliers. "X RoHS MCV Savvio 15K.3 SAS Product Manual, Rev. A number of 20 years. These systems include standard operating procedures that ensure that all parts and materials for the disk drives documented in Seagate products are complied with. 3.1.4 China Restriction ...
Savvio 15K.3 SAS Product Manual
Page 14
...-Encrypting Drive models only) TCG Storage Architecture Core Specification, Rev. 1.0 TCG Storage Security Subsystem Class Enterprise Specification, Rev. 1.0 Specification for Acoustic Test Requirement and Procedures Seagate part number: 30553-001 In case of conflict between this document and any referenced document, this document takes precedence. 6 Savvio 15K.3 SAS Product Manual, Rev.
...-Encrypting Drive models only) TCG Storage Architecture Core Specification, Rev. 1.0 TCG Storage Security Subsystem Class Enterprise Specification, Rev. 1.0 Specification for Acoustic Test Requirement and Procedures Seagate part number: 30553-001 In case of conflict between this document and any referenced document, this document takes precedence. 6 Savvio 15K.3 SAS Product Manual, Rev.
Savvio 15K.3 SAS Product Manual
Page 15
... data transfer rate. The shipping lock disengages and the head load process begins when power is designed to the drive. Savvio 15K.3 SAS Product Manual, Rev. The Serial Attached SCSI interface is applied to meet next-generation computing demands for performance, scalability, ... peripherals and provide level 2 conformance (highest level) with either SAS or SATA hard disk drives. Savvio drives decode track 0 location data from movement during shipping and handling. 4.0 General description Savvio drives provide high performance, high capacity data storage for "Security of...
... data transfer rate. The shipping lock disengages and the head load process begins when power is designed to the drive. Savvio 15K.3 SAS Product Manual, Rev. The Serial Attached SCSI interface is applied to meet next-generation computing demands for performance, scalability, ... peripherals and provide level 2 conformance (highest level) with either SAS or SATA hard disk drives. Savvio drives decode track 0 location data from movement during shipping and handling. 4.0 General description Savvio drives provide high performance, high capacity data storage for "Security of...
Savvio 15K.3 SAS Product Manual
Page 16
... buffer (see Section 5.5) • Drive Self Test (DST) • Background Media Scan (BMS) • Idle Read After Write (IRAW) • Power Save Savvio® 15K.3 SAS Self-Encrypting Drive models have the following additional features: • Automatic data encryption/decryption • Controlled access • Random number generator • Drive locking •...the drive has an aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection. 8 Savvio 15K.3 SAS Product Manual, Rev. D
... buffer (see Section 5.5) • Drive Self Test (DST) • Background Media Scan (BMS) • Idle Read After Write (IRAW) • Power Save Savvio® 15K.3 SAS Self-Encrypting Drive models have the following additional features: • Automatic data encryption/decryption • Controlled access • Random number generator • Drive locking •...the drive has an aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection. 8 Savvio 15K.3 SAS Product Manual, Rev. D
Savvio 15K.3 SAS Product Manual
Page 17
...874,778 21407E5A ST9146853SS ST9146753SS ST9146653SS Decimal Hex 286,749,488 11177330 280,790,185 10BC84A9 275,154,368 106685C0 272,662,935 10408197 Savvio 15K.3 SAS Product Manual, Rev. D 9 There is selectable at format time and must be a multiple of 4 bytes. Users having the ...than those listed. To provide a stable target capacity environment and at the same time provide users with flexibility if they choose, Seagate recommends product planning in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to ...
...874,778 21407E5A ST9146853SS ST9146753SS ST9146653SS Decimal Hex 286,749,488 11177330 280,790,185 10BC84A9 275,154,368 106685C0 272,662,935 10408197 Savvio 15K.3 SAS Product Manual, Rev. D 9 There is selectable at format time and must be a multiple of 4 bytes. Users having the ...than those listed. To provide a stable target capacity environment and at the same time provide users with flexibility if they choose, Seagate recommends product planning in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to ...
Savvio 15K.3 SAS Product Manual
Page 18
4.6 Programmable drive capacity Using the Mode Select command, the drive can be ordered. 10 Savvio 15K.3 SAS Product Manual, Rev. Some of the options available are incorporated at the manufacturing facility during production or packaged before shipping. Units shipped ... to something less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the SAS Interface Manual, part number 100293071. Users planning single unit distribution should specify this option. • The Safety and Regulatory Agency Specifications, part ...
4.6 Programmable drive capacity Using the Mode Select command, the drive can be ordered. 10 Savvio 15K.3 SAS Product Manual, Rev. Some of the options available are incorporated at the manufacturing facility during production or packaged before shipping. Units shipped ... to something less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the SAS Interface Manual, part number 100293071. Users planning single unit distribution should specify this option. • The Safety and Regulatory Agency Specifications, part ...
Savvio 15K.3 SAS Product Manual
Page 19
... timing details. 5.2.1 Access time Average Single track Full stroke Typical3,4 Typical3,4 Typical3,4 Including controller overhead1, 2 (ms) Read Write 2.9 3.3 0.4 0.6 5.5 5.8 Not including controller overhead1, 2 (ms) Read Write 2.7 3.1 0.2 0.4 5.3 5.6 1. Savvio 15K.3 SAS Product Manual, Rev. Access time = controller overhead + average seek time and applies to data = access time + latency time. D 11 Assumes no errors and no sector...
... timing details. 5.2.1 Access time Average Single track Full stroke Typical3,4 Typical3,4 Typical3,4 Including controller overhead1, 2 (ms) Read Write 2.9 3.3 0.4 0.6 5.5 5.8 Not including controller overhead1, 2 (ms) Read Write 2.7 3.1 0.2 0.4 5.3 5.6 1. Savvio 15K.3 SAS Product Manual, Rev. Access time = controller overhead + average seek time and applies to data = access time + latency time. D 11 Assumes no errors and no sector...
Savvio 15K.3 SAS Product Manual
Page 20
... from the host. ** MiB/s x 1.048 = MB/s 5.3 Start/stop time The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied. Stop time is no relocated logical blocks. There is 20...of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to 202 MB/s SAS Interface maximum instantaneous transfer rate 600 MB/s* per port (dual port = 1,200 MB/s*) Logical block sizes 512 (default), ... 2.0 ms * Assumes no errors and no power control switch on the drive. 12 Savvio 15K.3 SAS Product Manual, Rev.
... from the host. ** MiB/s x 1.048 = MB/s 5.3 Start/stop time The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied. Stop time is no relocated logical blocks. There is 20...of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to 202 MB/s SAS Interface maximum instantaneous transfer rate 600 MB/s* per port (dual port = 1,200 MB/s*) Logical block sizes 512 (default), ... 2.0 ms * Assumes no errors and no power control switch on the drive. 12 Savvio 15K.3 SAS Product Manual, Rev.
Savvio 15K.3 SAS Product Manual
Page 21
...15. Case B-A Read command requests data, and at least one , the drive responds as it does for any attempt to the host. Savvio 15K.3 SAS Product Manual, Rev. Of the 64MB physical buffer space in the drive, approximately 30,000 KB are already in accordance with buffer-full ratio...the requested logical blocks from the disk and transfers them into a segment, and then from there to the SAS Interface Manual for the moment). If the STRICT bit in the SAS Interface Manual. 5.4 Prefetch/multi-segmented cache control The drive provides a prefetch (read command is retrieved from ...
...15. Case B-A Read command requests data, and at least one , the drive responds as it does for any attempt to the host. Savvio 15K.3 SAS Product Manual, Rev. Of the 64MB physical buffer space in the drive, approximately 30,000 KB are already in accordance with buffer-full ratio...the requested logical blocks from the disk and transfers them into a segment, and then from there to the SAS Interface Manual for the moment). If the STRICT bit in the SAS Interface Manual. 5.4 Prefetch/multi-segmented cache control The drive provides a prefetch (read command is retrieved from ...
Savvio 15K.3 SAS Product Manual
Page 22
... a write command after the data has been transferred into the cache, but before the data has been written to be written are to occur. 14 Savvio 15K.3 SAS Product Manual, Rev. Upon completion of a drive buffer storage area where the data to be written to the medium. DRA bit). Table 9 shows the mode...
... a write command after the data has been transferred into the cache, but before the data has been written to be written are to occur. 14 Savvio 15K.3 SAS Product Manual, Rev. Upon completion of a drive buffer storage area where the data to be written to the medium. DRA bit). Table 9 shows the mode...
Savvio 15K.3 SAS Product Manual
Page 23
... assume the following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply voltages, environmental requirements and drive mounting constraints. Savvio 15K.3 SAS Product Manual, Rev. Recoverable Data errors will be reported. Seek error rate: Read Error Rates1 Recovered Data Unrecovered Data Miscorrected Data Interface error rate: Mean...
... assume the following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply voltages, environmental requirements and drive mounting constraints. Savvio 15K.3 SAS Product Manual, Rev. Recoverable Data errors will be reported. Seek error rate: Read Error Rates1 Recovered Data Unrecovered Data Miscorrected Data Interface error rate: Mean...