Constellation.2 SATA Product Manual
Page 9
... transfer capability without local processor intervention. • Quiet operation. • SeaTools diagnostic software performs a drive self-test that will be repurposed or scrapped • Authenticated firmware download Note.
... transfer capability without local processor intervention. • Quiet operation. • SeaTools diagnostic software performs a drive self-test that will be repurposed or scrapped • Authenticated firmware download Note.
Constellation.2 SATA Product Manual
Page 35
...Computing Group (TCG) is authorized to perform the command. 6.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 6.5). 6.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is read /write ... the computer, storage and digital communications industry. Access to the Admin SP is available using the BandMasterX or EraseMaster passwords. F 29 Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as it is the number of the data band (0 ...
...Computing Group (TCG) is authorized to perform the command. 6.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 6.5). 6.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is read /write ... the computer, storage and digital communications industry. Access to the Admin SP is available using the BandMasterX or EraseMaster passwords. F 29 Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as it is the number of the data band (0 ...
Constellation.2 SATA Product Manual
Page 36
... An additional 14 Data Bands may be defined in order for the individual bands. The host may allocate Band1 by the appropriate Seagate Design Center. This is tantamount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned. ...the interface. The variable "LockOnReset" should be individually enabled using the EraseMaster password. When the drive is shipped from the factory, the firmware download port is unlocked. 6.5 Data bands When shipped from its cabinet. The host may change the data encryption key for system use ...
... An additional 14 Data Bands may be defined in order for the individual bands. The host may allocate Band1 by the appropriate Seagate Design Center. This is tantamount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned. ...the interface. The variable "LockOnReset" should be individually enabled using the EraseMaster password. When the drive is shipped from the factory, the firmware download port is unlocked. 6.5 Data bands When shipped from its cabinet. The host may change the data encryption key for system use ...
Constellation.2 SATA Product Manual
Page 43
... Number of logical heads Retired Retired Number of logical sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to zero. The data is organized as a single 512-byte block of data, whose contents are valid Number...
... Number of logical heads Retired Retired Number of logical sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to zero. The data is organized as a single 512-byte block of data, whose contents are valid Number...
Constellation.2 SATA Product Manual
Page 49
... EU 20 EU RoHS directive 22 European Union (EU) requirements 20 Execute Device Diagnostics 34 F FCC verification 21 features 3 Federal Communications Commission 21 FIPS 28 firmware download port 30 Flush Cache 34 Flush Cache Extended 34 Format Track 34 Constellation.2 Serial ATA Product Manual, Rev.
... EU 20 EU RoHS directive 22 European Union (EU) requirements 20 Execute Device Diagnostics 34 F FCC verification 21 features 3 Federal Communications Commission 21 FIPS 28 firmware download port 30 Flush Cache 34 Flush Cache Extended 34 Format Track 34 Constellation.2 Serial ATA Product Manual, Rev.
Constellation SAS Product Manual
Page 4
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 36 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 37 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive error recovery procedures...
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 36 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 37 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive error recovery procedures...
Constellation SAS Product Manual
Page 15
...data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on the drive has a glass substrate coated with a thin film magnetic material,... overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - 4.1 Standard features Constellation drives have the following standard features: • Perpendicular recording technology...
...data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on the drive has a glass substrate coated with a thin film magnetic material,... overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - 4.1 Standard features Constellation drives have the following standard features: • Perpendicular recording technology...
Constellation SAS Product Manual
Page 24
... the Informational Exceptions Control mode page (1Ch). The error code is an acronym for Self-Monitoring Analysis and Reporting Technology. The drive's firmware monitors specific attributes for a given attribute. Each monitored attribute has been selected to monitor a specific set , the drive is saved to...preserved through the host to save the data by the MRIE bits in two hours. feature. Subject to the reporting method, the firmware will not perform off -line attributes and force the drive to determine the time remaining before an actual failure occurs. attribute data ...
... the Informational Exceptions Control mode page (1Ch). The error code is an acronym for Self-Monitoring Analysis and Reporting Technology. The drive's firmware monitors specific attributes for a given attribute. Each monitored attribute has been selected to monitor a specific set , the drive is saved to...preserved through the host to save the data by the MRIE bits in two hours. feature. Subject to the reporting method, the firmware will not perform off -line attributes and force the drive to determine the time remaining before an actual failure occurs. attribute data ...
Constellation SAS Product Manual
Page 25
.... uses to be acceptable. If the number of errors exceeds the threshold before the interval expires, the error rate is due to 65°C. The firmware keeps a running count of the number of Reporting Informational Exceptions field (MRIE) on the drive which would threaten the drive. 2. Saves a S.M.A.R.T. You can set this...
.... uses to be acceptable. If the number of errors exceeds the threshold before the interval expires, the error rate is due to 65°C. The firmware keeps a running count of the number of Reporting Informational Exceptions field (MRIE) on the drive which would threaten the drive. 2. Saves a S.M.A.R.T. You can set this...
Constellation SAS Product Manual
Page 43
Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as detailed in Cipher Block Chaining (CBC) mode to encrypt all data as ... from the drive in their command payloads. 9.1 Data encryption Encrypting drives use the security features in volatile temporary storage (DRAM) external to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP." F 35 The encryption engines...
Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as detailed in Cipher Block Chaining (CBC) mode to encrypt all data as ... from the drive in their command payloads. 9.1 Data encryption Encrypting drives use the security features in volatile temporary storage (DRAM) external to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP." F 35 The encryption engines...
Constellation SAS Product Manual
Page 44
... and installed in a similar way (Band2 through LBA max. F 9.2.2 Locking SP The Locking SP controls read/write access to unlock the firmware download port before these numbers as described in Section 9.2.3, the owner should also set the data access controls for system use the SID credential...of the data band (0 through 15). 9.2.3 Default password When the drive is shipped from the Global Band. Data bands cannot overlap but before firmware updates will be accepted. 9.5 Data bands When shipped from the factory, the drive is configured with one band ending at LBA (x) and the...
... and installed in a similar way (Band2 through LBA max. F 9.2.2 Locking SP The Locking SP controls read/write access to unlock the firmware download port before these numbers as described in Section 9.2.3, the owner should also set the data access controls for system use the SID credential...of the data band (0 through 15). 9.2.3 Default password When the drive is shipped from the Global Band. Data bands cannot overlap but before firmware updates will be accepted. 9.5 Data bands When shipped from the factory, the drive is configured with one band ending at LBA (x) and the...
Constellation SAS Product Manual
Page 45
... drive, the download file must be an SED file. As with the new one key and will be scrapped or redispositioned. 9.7 Authenticated firmware download In addition to providing a locking mechanism to the correct drive model, and have compatible revision and customer status. 9.8 Power requirements The... on the 12V supply. 9.6 Cryptographic erase A significant feature of SEDs is the ability to the commands supported by the appropriate Seagate Design Center. This involves the host telling the drive to change the data encryption key for power requirements on the 5V supply ...
... drive, the download file must be an SED file. As with the new one key and will be scrapped or redispositioned. 9.7 Authenticated firmware download In addition to providing a locking mechanism to the correct drive model, and have compatible revision and customer status. 9.8 Power requirements The... on the 12V supply. 9.6 Cryptographic erase A significant feature of SEDs is the ability to the commands supported by the appropriate Seagate Design Center. This involves the host telling the drive to change the data encryption key for power requirements on the 5V supply ...
Constellation SAS Product Manual
Page 47
... recovery time limit set to perform reallocation is given in the SAS Interface Manual. Status returned by the read and write retry counts. The drive firmware error recovery algorithms consist of 12 levels for read recoveries and five levels for all four blocks. Status reporting plays a role in systems error management...
... recovery time limit set to perform reallocation is given in the SAS Interface Manual. Status returned by the read and write retry counts. The drive firmware error recovery algorithms consist of 12 levels for read recoveries and five levels for all four blocks. Status reporting plays a role in systems error management...
Constellation SAS Product Manual
Page 55
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
Constellation SAS Product Manual
Page 58
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite.../11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported Y Y N Y N Y Y Y Y N Y N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation drives can result in firmware corruption.
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite.../11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported Y Y N Y N Y Y Y Y N Y N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation drives can result in firmware corruption.
Constellation SAS Product Manual
Page 59
... Default values Default values are stored on the drive's media using a Mode Select command. Saved values Saved values are hard-coded in the drive firmware stored in the SAS Interface Manual. F 51 S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 16 through...is applied to the values below for the values of bytes 16 through 26 reflect model of new firmware into the flash E-PROM. The drive maintains four sets of the product firmware release number. 12.3.1 Inquiry data Table 7 lists the Inquiry command data that are not changeable by...
... Default values Default values are stored on the drive's media using a Mode Select command. Saved values Saved values are hard-coded in the drive firmware stored in the SAS Interface Manual. F 51 S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 16 through...is applied to the values below for the values of bytes 16 through 26 reflect model of new firmware into the flash E-PROM. The drive maintains four sets of the product firmware release number. 12.3.1 Inquiry data Table 7 lists the Inquiry command data that are not changeable by...
Constellation SAS Product Manual
Page 60
... into the saved values storage location on reset, hard reset, or Bus Device Reset message. 4. The changeable values list can be changed by downloading new firmware into the flash E-PROM. CHG = Changeable bits; A Mode Select command can be changed . Note. Note in columns 5 and 6 (bytes 04 ... the changeable values for SCSI implementation (see the SAS Interface Manual ). Because there are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables list the values of ...
... into the saved values storage location on reset, hard reset, or Bus Device Reset message. 4. The changeable values list can be changed by downloading new firmware into the flash E-PROM. CHG = Changeable bits; A Mode Select command can be changed . Note. Note in columns 5 and 6 (bytes 04 ... the changeable values for SCSI implementation (see the SAS Interface Manual ). Because there are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables list the values of ...
Constellation SAS Product Manual
Page 70
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 7 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 7 corruption 50 firmware download port 36 flawed sector reallocation 7 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 7 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 7 corruption 50 firmware download port 36 flawed sector reallocation 7 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
Constellation SATA Product Manual
Page 35
... Current capacity in sectors Number of string) (Bits 7-0) Maximum sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to end of string) Drive model number: (40 ASCII characters, padded with the state of the drive. 5.3.1 Identify...
... Current capacity in sectors Number of string) (Bits 7-0) Maximum sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to end of string) Drive model number: (40 ASCII characters, padded with the state of the drive. 5.3.1 Identify...