Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
Savvio 10K.1 SAS Product Manual
Page 7
D 1 Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives.
D 1 Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives.
Savvio 10K.1 SAS Product Manual
Page 13
Savvio drives are random access storage devices designed to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general ...
Savvio drives are random access storage devices designed to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general ...
Savvio 10K.1 SAS Product Manual
Page 14
...read reallocation • Reallocation of defects on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; D 3.1 Standard features Savvio drives have the following ... features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec ...
...read reallocation • Reallocation of defects on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; D 3.1 Standard features Savvio drives have the following ... features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec ...
Savvio 10K.1 SAS Product Manual
Page 20
... to the medium. The wrap-around capability of the individual segments greatly enhances the cache's overall performance, allowing a wide range of the segment. The drive supports operation of any segment of segments to 16. Divide the 6,900 Kbytes in bit 4 of byte 2 of RCD. The size of each segment is always...
... to the medium. The wrap-around capability of the individual segments greatly enhances the cache's overall performance, allowing a wide range of the segment. The drive supports operation of any segment of segments to 16. Divide the 6,900 Kbytes in bit 4 of byte 2 of RCD. The size of each segment is always...
Savvio 10K.1 SAS Product Manual
Page 45
...LBA can be limited using the Read Retry Count or Write Retry Count bytes in error recovery for write. The error recovery scheme supported by the host (initiator). Table 14 equates the read and write retry count with this section. The read and write recovery of...drive implements selectable error recovery time limits required in communications between the initiator and the drive). The total amount of the SCSI commands supported by the initiator using several SCSI commands described in this product manual. The times given do so, performs error recovery procedures to ...
...LBA can be limited using the Read Retry Count or Write Retry Count bytes in error recovery for write. The error recovery scheme supported by the host (initiator). Table 14 equates the read and write retry count with this section. The read and write recovery of...drive implements selectable error recovery time limits required in communications between the initiator and the drive). The total amount of the SCSI commands supported by the initiator using several SCSI commands described in this product manual. The times given do so, performs error recovery procedures to ...
Savvio 10K.1 SAS Product Manual
Page 51
... Logical Unit Reset Yes Query Task Yes 9.1.2 task management responses Table 16 lists the SAS response codes returned for task management functions supported. D 45 Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not... supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. Additional information is provided in the ...
... Logical Unit Reset Yes Query Task Yes 9.1.2 task management responses Table 16 lists the SAS response codes returned for task management functions supported. D 45 Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not... supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. Additional information is provided in the ...
Savvio 10K.1 SAS Product Manual
Page 52
...complete speed negotiation looses sync before the second port completes speed negotiation, both ports revert back to successfully complete speed negotiation sets the link rate support by the first port. Each drive port has a unique SAS address. The two ports run at the same time. • Full duplex-... XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. 46 Savvio SAS Product Manual, Rev. When the second port participates in the same or ...
...complete speed negotiation looses sync before the second port completes speed negotiation, both ports revert back to successfully complete speed negotiation sets the link rate support by the first port. Each drive port has a unique SAS address. The two ports run at the same time. • Full duplex-... XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. 46 Savvio SAS Product Manual, Rev. When the second port participates in the same or ...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in firmware corruption. ...
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in firmware corruption. ...
Savvio 10K.1 SAS Product Manual
Page 61
...Savvio SAS Product Manual, Rev. D 55 9.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event notification Synchronized (locked) spindle operation ...Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count...
...Savvio SAS Product Manual, Rev. D 55 9.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event notification Synchronized (locked) spindle operation ...Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - Short pin to eliminate ground shift noise. input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6...
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - Short pin to eliminate ground shift noise. input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6...
Savvio 10K.1 SAS Product Manual
Page 71
... V+ and V- All specifications are measured from 20 % to 80 % of the Tx+ signal and the Tx- signal. The same stable trigger, coherent to the lowest supported transfer rate. RMS amplitudes.
... V+ and V- All specifications are measured from 20 % to 80 % of the Tx+ signal and the Tx- signal. The same stable trigger, coherent to the lowest supported transfer rate. RMS amplitudes.
Savvio 10K.1 SAS Product Manual
Page 79
... that are best suited for the call centers. Submit pricing requests, orders and returns through one of our call center in the world. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for your questions. To learn more about the benefits or to register, go to spp...
... that are best suited for the call centers. Submit pricing requests, orders and returns through one of our call center in the world. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for your questions. To learn more about the benefits or to register, go to spp...
Savvio 10K.1 SAS Product Manual
Page 80
...go to the "Contact Us" page on www.seagate.com. Have your customer support representative for the location nearest you. USA/Canada/Latin America support services For an extensive list of telephone numbers to technical support, presales and warranty service in Europe, the ... is available at http://services.seagate.com/index.aspx Authorized Service Centers Seagate Service Centers are currently located throughout the world. . Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center ...
...go to the "Contact Us" page on www.seagate.com. Have your customer support representative for the location nearest you. USA/Canada/Latin America support services For an extensive list of telephone numbers to technical support, presales and warranty service in Europe, the ... is available at http://services.seagate.com/index.aspx Authorized Service Centers Seagate Service Centers are currently located throughout the world. . Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center ...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
...37 mounting configuration dimensions 37 Savvio SAS Product Manual, Rev. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
...37 mounting configuration dimensions 37 Savvio SAS Product Manual, Rev. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...