Operating Instructions
Page 6
... Commission has these guidelines: first three months of pregnancy resulting in the birth of the heater can be installed and operated by trained personnel in regulating water temperatures by as much as tranquilizers, antihistamines, anticoagulants, or recreational drugs should not use may... (38°C) is considered safe for Gas-Fired Pool Heaters. The heater can be used either indoors or outdoors. A temperature of alcoholic beverages before using spas or hot tubs. 6. Ratings & Certifications This pool & spa heater is design-certified and tested under the latest requirements of ...
... Commission has these guidelines: first three months of pregnancy resulting in the birth of the heater can be installed and operated by trained personnel in regulating water temperatures by as much as tranquilizers, antihistamines, anticoagulants, or recreational drugs should not use may... (38°C) is considered safe for Gas-Fired Pool Heaters. The heater can be used either indoors or outdoors. A temperature of alcoholic beverages before using spas or hot tubs. 6. Ratings & Certifications This pool & spa heater is design-certified and tested under the latest requirements of ...
Operating Instructions
Page 14
...a pressure relief valve. If pipe is 125 psi. To conform to local building codes, it is maintained through the heater and accompanying reduction in the system. If there is any possibility of water flow is recommended that a check valve (or valves) also be necessary to the spa jets, etc. Outlet pipes ...flow rate. A 3/4" pressure relief valve, having a capacity equal to be used when flow rates exceed 70 GPM. The maximum pressure relief valve setting is hot, close bypass; This relief valve needs to the BTUH output of Piping Fig. 16: Pressure Relief Valve Installed 14
...a pressure relief valve. If pipe is 125 psi. To conform to local building codes, it is maintained through the heater and accompanying reduction in the system. If there is any possibility of water flow is recommended that a check valve (or valves) also be necessary to the spa jets, etc. Outlet pipes ...flow rate. A 3/4" pressure relief valve, having a capacity equal to be used when flow rates exceed 70 GPM. The maximum pressure relief valve setting is hot, close bypass; This relief valve needs to the BTUH output of Piping Fig. 16: Pressure Relief Valve Installed 14
Operating Instructions
Page 16
...electric shock, disconnect all connections before servicing. HOT former wire 240V HOOK-UP SUPPLY SIDE HOT L1 BLACK HOT L2 RED GREEN BLACK RED GREEN WHITE Fig. 18: 240V Hook-Up HEATER COOL Knobstop Set Screw Knobstop Ring Fig. 19: Water Temperature Thermostat NOTE: Maximum temperature is controlled ... the upper temperature limit below the maximum level. Installation Instructions-240 Volt Control Adjustments-Millivolt CAUTION: This heater has provisions to be connected to the red and black wire on white transformer wire. 3. The pool or spa water temperature is 104°F. 16
...electric shock, disconnect all connections before servicing. HOT former wire 240V HOOK-UP SUPPLY SIDE HOT L1 BLACK HOT L2 RED GREEN BLACK RED GREEN WHITE Fig. 18: 240V Hook-Up HEATER COOL Knobstop Set Screw Knobstop Ring Fig. 19: Water Temperature Thermostat NOTE: Maximum temperature is controlled ... the upper temperature limit below the maximum level. Installation Instructions-240 Volt Control Adjustments-Millivolt CAUTION: This heater has provisions to be connected to the red and black wire on white transformer wire. 3. The pool or spa water temperature is 104°F. 16
Operating Instructions
Page 20
..., remove the door and make a visual check of Pilot must be hot. When temperatures are reached. CAUTION: Do not use the heater to the appliance. Fig. 23: Millivolt Pilot Burner Flame For cold climate areas, please follow the winterizing procedures listed in the next ... warranted against freeze-ups. Igniter Minimum Spark Gap is used during short-term cold spells. Should this occur, shut the heater off the manual gas control to maintain water temperatures just above Burner Deck. Post Start-Up Inspection Feel the inlet and outlet pipes. Outlet pipe should be required....
..., remove the door and make a visual check of Pilot must be hot. When temperatures are reached. CAUTION: Do not use the heater to the appliance. Fig. 23: Millivolt Pilot Burner Flame For cold climate areas, please follow the winterizing procedures listed in the next ... warranted against freeze-ups. Igniter Minimum Spark Gap is used during short-term cold spells. Should this occur, shut the heater off the manual gas control to maintain water temperatures just above Burner Deck. Post Start-Up Inspection Feel the inlet and outlet pipes. Outlet pipe should be required....
Operating Instructions
Page 27
...Clean burners. Outer jacket very hot (paint blistered) *Broken refractory caused by adding manual bypass valve. Takes too long to weather. Leaking at well Overacid Replace well and maintain proper water chemistry. Refractory damage Sooted heater See Pressure Switch Adjustment. PROBLEM ... backflow preventer. Flush system and clean. Outlet pipes hot to installation instructions. Heater going on initial start-up. 27 Clean or replace filter. Raise water level. Adjust manual bypass valve until heater outlet water temperature is between 105°F and 110°F. ...
...Clean burners. Outer jacket very hot (paint blistered) *Broken refractory caused by adding manual bypass valve. Takes too long to weather. Leaking at well Overacid Replace well and maintain proper water chemistry. Refractory damage Sooted heater See Pressure Switch Adjustment. PROBLEM ... backflow preventer. Flush system and clean. Outlet pipes hot to installation instructions. Heater going on initial start-up. 27 Clean or replace filter. Raise water level. Adjust manual bypass valve until heater outlet water temperature is between 105°F and 110°F. ...