... ■ ¼" nut driver and nut driver 3.2 mm) drill bit (for wood floors) 4.8 mm) carbide-tipped masonry drill bit (for concrete/ceramic floors) ■ Tin snips or large wire cutters (for Mobile Home Construction and Safety, Title 24, HUD Part 280). If cabinet storage is installed ... for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local codes. Any method of this range is to make sure that are minimum clearances. ■ The floor anti-tip bracket must be rated at 250 volts minimum, 40 amps or 50 amps that all governing codes and ordinances....
... ■ ¼" nut driver and nut driver 3.2 mm) drill bit (for wood floors) 4.8 mm) carbide-tipped masonry drill bit (for concrete/ceramic floors) ■ Tin snips or large wire cutters (for Mobile Home Construction and Safety, Title 24, HUD Part 280). If cabinet storage is installed ... for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local codes. Any method of this range is to make sure that are minimum clearances. ■ The floor anti-tip bracket must be rated at 250 volts minimum, 40 amps or 50 amps that all governing codes and ordinances....
Installation Instructions
Page 4
... 70-latest edition and all local codes and ordinances. If it is covered by not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform ...the leveling legs. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can be installed next to whether the appliance is properly grounded. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination ...
... 70-latest edition and all local codes and ordinances. If it is covered by not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform ...the leveling legs. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can be installed next to whether the appliance is properly grounded. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination ...
Installation Instructions
Page 5
... must be used , a matching UL listed, 4-wire, 250-volt, 40- If connecting to a 4-wire system: This range is less than the total connected load listed on the model/serial rating plate. **If connecting to a 50-amp circuit, use with a UL listed strain relief and be identified by a green ...yellow cover and the neutral conductor by a link. Connectors on the model/serial number rating plate. Range Rating* 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW 120/208 Volts 7.8 - 12.5 KW 12.6 - 18.5 KW Specified Rating of Power Supply Cord Kit and Circuit Protection Amps 40 or 50** 50 *The ...
... must be used , a matching UL listed, 4-wire, 250-volt, 40- If connecting to a 4-wire system: This range is less than the total connected load listed on the model/serial rating plate. **If connecting to a 50-amp circuit, use with a UL listed strain relief and be identified by a green ...yellow cover and the neutral conductor by a link. Connectors on the model/serial number rating plate. Range Rating* 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW 120/208 Volts 7.8 - 12.5 KW 12.6 - 18.5 KW Specified Rating of Power Supply Cord Kit and Circuit Protection Amps 40 or 50** 50 *The ...
Installation Instructions
Page 9
... the green ground wire from the power supply cord to neutral wire of range. Ground-link screw C. Green ground wire E. Line 1 (black) 3. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for...if local codes permit connecting chassis ground conductor to the range with nominal 1³⁄₈" (3.5 cm) diameter connection opening 2. Tighten strain relief screws. 6. Terminal block B. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps ...
... the green ground wire from the power supply cord to neutral wire of range. Ground-link screw C. Green ground wire E. Line 1 (black) 3. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for...if local codes permit connecting chassis ground conductor to the range with nominal 1³⁄₈" (3.5 cm) diameter connection opening 2. Tighten strain relief screws. 6. Terminal block B. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps ...