hp lc 2000 and virtual array config guide — for the VA 7400 in Microsoft Windows NT Clusters PDF, 227K, 3/8/2002
Page 1
...8226; Power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of main memory. 1000...and illustrations that conforms to build an operational server cluster supported by Hewlett-Packard for interconnection of failure (SPOFs). HP Netserver LC 2000 with HP Surestore Virtual Array 7400 Windows NT® 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines the server ...
...8226; Power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of main memory. 1000...and illustrations that conforms to build an operational server cluster supported by Hewlett-Packard for interconnection of failure (SPOFs). HP Netserver LC 2000 with HP Surestore Virtual Array 7400 Windows NT® 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines the server ...
HP Netserver Family Brochure
Page 6
...HP Netserver Assured Availability solutions, MS Cluster certified hp netserver family features/specifications Microprocessors supported Number of processors (maximum) Processor upgrade Memory Standard Maximum ECC External cache Mass storage Max. HP Netserver Navigator assures rapid setup and deployment; DAT autoloader; HP Netserver Assured Availability solutions, MS Cluster certified hp netserver...drive, 1 CD-ROM drive preinstalled. physically compatible with standard 19-inch racks hp netserver lc 2000/2000r Intel Pentium III 800MHz/866MHz/933MHz/1GHz 2 Yes, to dual Intel ...
...HP Netserver Assured Availability solutions, MS Cluster certified hp netserver family features/specifications Microprocessors supported Number of processors (maximum) Processor upgrade Memory Standard Maximum ECC External cache Mass storage Max. HP Netserver Navigator assures rapid setup and deployment; DAT autoloader; HP Netserver Assured Availability solutions, MS Cluster certified hp netserver...drive, 1 CD-ROM drive preinstalled. physically compatible with standard 19-inch racks hp netserver lc 2000/2000r Intel Pentium III 800MHz/866MHz/933MHz/1GHz 2 Yes, to dual Intel ...
HP Netserver LC 2000 FC Config Guide
Page 1
...SPOFless cluster, refer to the HP white paper, High Availability MSCS Cluster Solution on the HP NetServers, HA Planning website. 1 See Client LAN below . This guide is HP and Microsoft approved. The specific configuration certified and supported by HP. What's Defined in Cluster ... These configurations minimize single points of this document) Introduction This document defines supported HP NetServer LC 2000 configurations with HP Rack Storage/12FC and Microsoft Cluster Server. HP NetServer LC 2000 with HP Rack Storage/12FC Cluster Configuration Guide 22 February 2001 (see Versions at the ...
...SPOFless cluster, refer to the HP white paper, High Availability MSCS Cluster Solution on the HP NetServers, HA Planning website. 1 See Client LAN below . This guide is HP and Microsoft approved. The specific configuration certified and supported by HP. What's Defined in Cluster ... These configurations minimize single points of this document) Introduction This document defines supported HP NetServer LC 2000 configurations with HP Rack Storage/12FC and Microsoft Cluster Server. HP NetServer LC 2000 with HP Rack Storage/12FC Cluster Configuration Guide 22 February 2001 (see Versions at the ...
HP Netserver LC 2000 FC Config Guide
Page 2
...HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in RAID-1 mirror, or another fault tolerant RAID level. Local storage ( NetRAID-1Si) P3 - Client LAN ( D5013B) P5 - of CPUs BIOS version CPU cache RAM No. Must be HP...P1 - of power supplies Local storage I/O slot Default Boot Order M/S Certified Configuration Storage HP NetServer LC 2000 1000 MHz 2 4.06.29 PV or later Any size 128 MB minimum. Any Shared HP Rack Storage/12FC Required 2 Direct from NetRAID-1Si Local Controller Driver Cabinets (Physical drive ...
...HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in RAID-1 mirror, or another fault tolerant RAID level. Local storage ( NetRAID-1Si) P3 - Client LAN ( D5013B) P5 - of CPUs BIOS version CPU cache RAM No. Must be HP...P1 - of power supplies Local storage I/O slot Default Boot Order M/S Certified Configuration Storage HP NetServer LC 2000 1000 MHz 2 4.06.29 PV or later Any size 128 MB minimum. Any Shared HP Rack Storage/12FC Required 2 Direct from NetRAID-1Si Local Controller Driver Cabinets (Physical drive ...
HP Netserver LC 2000 Installation Guide
Page 69
...PCI slots (P1 through P6), two of which are required for installation or removal of tested PCI boards, check for the specific NOS used in the HP NetServer LC 2000/2000r: • An anti-static service kit (3M™ 8501/8502/8503 or equivalent). National Electrical code (NFPA 70...) Class 2 or limited power source limits and must use of the HP NetServer LC 2000/2000r. Remote Control Card The HP NetServer LC 2000/2000r may exceed U.S. An I2C connector is provided on the Navigator CD-ROM or look for the Hardware Tested Products...
...PCI slots (P1 through P6), two of which are required for installation or removal of tested PCI boards, check for the specific NOS used in the HP NetServer LC 2000/2000r: • An anti-static service kit (3M™ 8501/8502/8503 or equivalent). National Electrical code (NFPA 70...) Class 2 or limited power source limits and must use of the HP NetServer LC 2000/2000r. Remote Control Card The HP NetServer LC 2000/2000r may exceed U.S. An I2C connector is provided on the Navigator CD-ROM or look for the Hardware Tested Products...
HP Netserver LC 2000 Installation Guide
Page 169
... 545 540 5.5 120 VAC 531 525 4.5 208 VAC 516 506 2.5 230/240 VAC 514 504 2.3 161 A Specifications Power Requirements Table A-1. NOTE Some local codes do not allow 16-amp service for each 16-Amp PDU. HP NetServer LC 2000/2000r Input Power Input Voltage and Frequency Maximum inrush current Delayed action circuit breaker recommended 100...
... 545 540 5.5 120 VAC 531 525 4.5 208 VAC 516 506 2.5 230/240 VAC 514 504 2.3 161 A Specifications Power Requirements Table A-1. NOTE Some local codes do not allow 16-amp service for each 16-Amp PDU. HP NetServer LC 2000/2000r Input Power Input Voltage and Frequency Maximum inrush current Delayed action circuit breaker recommended 100...
HP Netserver LC 2000 Installation Guide
Page 180
EMC Directive 89/336/EEC including CE Marking Directive 93/68/EEC - Operation is subject to the following Product Specifications: Safety: IEC 950: 1991+A1, A2, A3, A4 / EN 60950: 1992+A1, A2, A3 EMC: CISPR 22:1993 / EN 55022:1994 EN ... Company Manufacturer's/Supplier Address: 10955 Tantau Avenue Cupertino, CA 95015 USA declares, that the product Product Name: Model Number(s): Product Options: Network Server HP NetServer LC 2000/LC 2000r ALL conforms to the following two conditions: ì This device may not cause harmful interference, and ì This device must accept any ...
EMC Directive 89/336/EEC including CE Marking Directive 93/68/EEC - Operation is subject to the following Product Specifications: Safety: IEC 950: 1991+A1, A2, A3, A4 / EN 60950: 1992+A1, A2, A3 EMC: CISPR 22:1993 / EN 55022:1994 EN ... Company Manufacturer's/Supplier Address: 10955 Tantau Avenue Cupertino, CA 95015 USA declares, that the product Product Name: Model Number(s): Product Options: Network Server HP NetServer LC 2000/LC 2000r ALL conforms to the following two conditions: ì This device may not cause harmful interference, and ì This device must accept any ...
hp netserver lc 2000 netraid-2m config guide — for Microsoft NT 4.0 Clusters PDF, 210K, 2/23/2002
Page 1
...RAM Specification HP Netserver LC 2000, Ultra3 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of two HP Netserver LC 2000 servers and one or multiple HP Rack Storage/12 disk drive enclosure(s), with Microsoft® Cluster Server software. Two Version 4.06.04 RM, or later Any size 128 MB...174; is detailed in an inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs. HP Netserver LC 2000 with NetRAID-2M (HP Rack Storage/12) Windows NT® 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines ...
...RAM Specification HP Netserver LC 2000, Ultra3 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of two HP Netserver LC 2000 servers and one or multiple HP Rack Storage/12 disk drive enclosure(s), with Microsoft® Cluster Server software. Two Version 4.06.04 RM, or later Any size 128 MB...174; is detailed in an inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs. HP Netserver LC 2000 with NetRAID-2M (HP Rack Storage/12) Windows NT® 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines ...
hp netserver lc 2000 netraid-2m config guide — for Microsoft Windows 2000 A.S. Clusters PDF, 209K, 8/13/2001
Page 1
...standard, two required for interconnection of two HP Netserver LC 2000 servers and one or two HP Rack Storage/12 disk drive enclosure(s), ... of failure (SPOFs). For revision/update information on page 7. HP Netserver LC 2000 with NetRAID-2M (HP Rack Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide Introduction This document defines the server...Number of CPUs BIOS CPU cache RAM Number of this document, refer to the guidelines of power supplies Specification HP Netserver LC 2000, Ultra 3 models Two Each node must be HP. These configurations provide high server ...
...standard, two required for interconnection of two HP Netserver LC 2000 servers and one or two HP Rack Storage/12 disk drive enclosure(s), ... of failure (SPOFs). For revision/update information on page 7. HP Netserver LC 2000 with NetRAID-2M (HP Rack Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide Introduction This document defines the server...Number of CPUs BIOS CPU cache RAM Number of this document, refer to the guidelines of power supplies Specification HP Netserver LC 2000, Ultra 3 models Two Each node must be HP. These configurations provide high server ...
HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Server Cluster Config Guide
Page 1
...HP NetServer LC 2000 Each node must be supported by HP. it describes the configurations supported by HP. The specific configuration certified and supported by both Hewlett-Packard and Microsoft is defined, as are other guidelines to these configurations can result in configuring your clustered NetServers... NIC that Hewlett-Packard supports for the HP NetServer LC 2000, HP Rack Storage/12 and Microsoft Cluster Server. This guide is prescriptive; HP NetServer LC 2000 with NetRAID-3Si (HP Rack Storage/12) Windows 2000 Advanced Server Cluster Configuration Guide 29 January 2001...
...HP NetServer LC 2000 Each node must be supported by HP. it describes the configurations supported by HP. The specific configuration certified and supported by both Hewlett-Packard and Microsoft is defined, as are other guidelines to these configurations can result in configuring your clustered NetServers... NIC that Hewlett-Packard supports for the HP NetServer LC 2000, HP Rack Storage/12 and Microsoft Cluster Server. This guide is prescriptive; HP NetServer LC 2000 with NetRAID-3Si (HP Rack Storage/12) Windows 2000 Advanced Server Cluster Configuration Guide 29 January 2001...
HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Server Cluster Config Guide
Page 2
.... SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. Any Shared Controller Model No. of CPUs BIOS version CPU cache RAM No. NetRAID-1Si P3 - Client LAN P5 - Must be installed in mind the server's default boot order as listed... L.18.00 or later Microsoft Windows 2000 Advanced Server HP NetServer LC 2000 933, 1000 MHz 2 4.06.23 PV or later (933 MHz) 4.06.29 PV or later (1000 MHz) Any size 256 MB minimum. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in ...
.... SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. Any Shared Controller Model No. of CPUs BIOS version CPU cache RAM No. NetRAID-1Si P3 - Client LAN P5 - Must be installed in mind the server's default boot order as listed... L.18.00 or later Microsoft Windows 2000 Advanced Server HP NetServer LC 2000 933, 1000 MHz 2 4.06.23 PV or later (933 MHz) 4.06.29 PV or later (1000 MHz) Any size 256 MB minimum. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in ...
HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows NT 4.0 Enterprise Server Cluster Config Guide
Page 1
... of this document) Introduction This document defines the supported HP NetServer LC 2000 configuration with degraded performance, hidden SPOFs, etc., and therefore will not be the same model SPU, but may have different sizes of main memory, cache, and different CPU clock speeds. The specific configuration certified and supported by both Hewlett-Packard and Microsoft...
... of this document) Introduction This document defines the supported HP NetServer LC 2000 configuration with degraded performance, hidden SPOFs, etc., and therefore will not be the same model SPU, but may have different sizes of main memory, cache, and different CPU clock speeds. The specific configuration certified and supported by both Hewlett-Packard and Microsoft...
HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows NT 4.0 Enterprise Server Cluster Config Guide
Page 2
...HP NetServer LC 2000 533, 600, 667, 733, 800, 933, 1000 MHz 2 4.06.20 PV or later (533, 600, 733 MHz) 4.06.23 PV or later (800, 933 MHz) 4.06.25 PV or later (1000 MHz) Any size 128 MB... System software: Navigator version Operating System Service pack supply (UPS) using any number. Must be HP. 1 standard, 2 required for redundancy See Local Storage below : IDE CD-ROM, FDD, ... speed No. Added cards may be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in ...or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. ...
...HP NetServer LC 2000 533, 600, 667, 733, 800, 933, 1000 MHz 2 4.06.20 PV or later (533, 600, 733 MHz) 4.06.23 PV or later (800, 933 MHz) 4.06.25 PV or later (1000 MHz) Any size 128 MB... System software: Navigator version Operating System Service pack supply (UPS) using any number. Must be HP. 1 standard, 2 required for redundancy See Local Storage below : IDE CD-ROM, FDD, ... speed No. Added cards may be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any appropriate slot, keeping in ...or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. ...
hp netserver lc 2000 netraid-3si config guide — for Microsoft Windows 2000 A.S. Clusters PDF, 271K, 1/26/2002
Page 1
... or later 800, 933 MHz -Version 4.06.23 PV or later 1000 MHz - Version 4.06.25 PV or later Any size 256 MB, minimum. Therefore, deviations are listed below, and their associated configuration data is included, but any cluster configuration that follow. • Server configuration...8226; SCSI cabling and power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Each node must be the same server type, but CPU clock speed, cache sizes, and main...
... or later 800, 933 MHz -Version 4.06.23 PV or later 1000 MHz - Version 4.06.25 PV or later Any size 256 MB, minimum. Therefore, deviations are listed below, and their associated configuration data is included, but any cluster configuration that follow. • Server configuration...8226; SCSI cabling and power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Each node must be the same server type, but CPU clock speed, cache sizes, and main...
hp netserver lc 2000 netraid-3si configuration — for Microsoft NT 4.0 Clusters PDF, 272K, 1/26/2002
Page 1
... an inoperative cluster, an operating cluster with Microsoft® Cluster Server software. Version 4.06.25 PV or later Any size 128 MB, minimum. Must be supported by Hewlett-Packard. The various server cluster elements are not supported. For revision/update information on this ...; SCSI cabling and power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Each node must be the same server type, but CPU clock speed, cache sizes, and main...
... an inoperative cluster, an operating cluster with Microsoft® Cluster Server software. Version 4.06.25 PV or later Any size 128 MB, minimum. Must be supported by Hewlett-Packard. The various server cluster elements are not supported. For revision/update information on this ...; SCSI cabling and power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Each node must be the same server type, but CPU clock speed, cache sizes, and main...
HP Netserver LC 2000 NetRAID-4M Config Guide
Page 1
Any deviance to assist you in configuring your clustered Netservers. The specific configuration certified and supported by both Hewlett-Packard and Microsoft® is HP and Microsoft® approved. See Intra-cluster LAN below . These configurations minimize single points of this document) Introduction This ... Storage Cabling Cluster Type of SPUs Number of nodes Shared Storage LANs: Client LAN Intra-cluster (Heartbeat) LAN Power source HP Netserver LC 2000 Each node must be the same SPU, but may have different clocks speeds, main memory sizes, cache sizes, and number of CPUs...
Any deviance to assist you in configuring your clustered Netservers. The specific configuration certified and supported by both Hewlett-Packard and Microsoft® is HP and Microsoft® approved. See Intra-cluster LAN below . These configurations minimize single points of this document) Introduction This ... Storage Cabling Cluster Type of SPUs Number of nodes Shared Storage LANs: Client LAN Intra-cluster (Heartbeat) LAN Power source HP Netserver LC 2000 Each node must be the same SPU, but may have different clocks speeds, main memory sizes, cache sizes, and number of CPUs...
HP Netserver LC 2000 NetRAID-4M Config Guide
Page 2
... HP Any HP cables that meet SCSI specifications and any power conditioner or UPS. D5013B P5 - of CPUs BIOS version CPU cache RAM No. NetRAID-4M Booted from Navigator L.20.00 or later. L.20.00 or later Microsoft Windows NT® Server 4.0 Enterprise Edition SP6a HP Netserver LC 2000 1000 MHz 2 4.06.29 PV or later Any size 128 MB...
... HP Any HP cables that meet SCSI specifications and any power conditioner or UPS. D5013B P5 - of CPUs BIOS version CPU cache RAM No. NetRAID-4M Booted from Navigator L.20.00 or later. L.20.00 or later Microsoft Windows NT® Server 4.0 Enterprise Edition SP6a HP Netserver LC 2000 1000 MHz 2 4.06.29 PV or later Any size 128 MB...
hp netserver lc 2000 netraid-4m config guide — for Microsoft NT 4.0 clusters PDF, 189K, 1/28/2002
Page 1
... supported by Hewlett-Packard. These configurations provide high server cluster availability and minimize single points of CPUs BIOS CPU cache Specification HP Netserver LC 2000, Ultra2 or Ultra3 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of the certified... supported by Hewlett-Packard. Two Ultra2 models - Version 4.06.04 RM, or later Any size 1/28/02 1 HP Netserver LC 2000 with NetRAID-4M (HP Rack Storage/12) Windows NT® Server 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines the server cluster ...
... supported by Hewlett-Packard. These configurations provide high server cluster availability and minimize single points of CPUs BIOS CPU cache Specification HP Netserver LC 2000, Ultra2 or Ultra3 embedded SCSI models Two Do not mix ultra2 and ultra3 models within 500 MHz of the certified... supported by Hewlett-Packard. Two Ultra2 models - Version 4.06.04 RM, or later Any size 1/28/02 1 HP Netserver LC 2000 with NetRAID-4M (HP Rack Storage/12) Windows NT® Server 4.0 Enterprise Edition Cluster Configuration Guide Introduction This document defines the server cluster ...
hp netserver lc 2000 netraid-4m config guide — for Microsoft Windows 2000 A.S. Clusters PDF, 189K, 1/28/2002
Page 1
...result in separate tables and illustrations that conforms to the guidelines of this document, refer to 4.06.30 PV Any size 256 MB, minimum. The various server cluster elements are not supported. For revision/update information on page 7. Each node must be the same... Parameter Server Type Number of nodes Clock speed Number of two HP Netserver LC 2000 servers and up to build an operational server cluster supported by Hewlett-Packard for interconnection of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Do not mix ultra2 and ultra3...
...result in separate tables and illustrations that conforms to the guidelines of this document, refer to 4.06.30 PV Any size 256 MB, minimum. The various server cluster elements are not supported. For revision/update information on page 7. Each node must be the same... Parameter Server Type Number of nodes Clock speed Number of two HP Netserver LC 2000 servers and up to build an operational server cluster supported by Hewlett-Packard for interconnection of CPUs BIOS CPU cache RAM Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Do not mix ultra2 and ultra3...
HP Netserver LC 2000 RS/12FC /Windows 2000 Advanced Server Cluster Configuration Guide
Page 2
... HP cables that meet SCSI specifications and... arrays Required HP Fibre Channel Host Bus Adapter - of controllers Driver SPU I /O slots: HP NetServer LC 2000 733 MHz 2 4.06.20 PV or later Any size 256 MB minimum. Local...2000 Advanced Server. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. May not use embedded SCSI or NetRAID-1Si in PCI slot P1. Any Shared HP... Rack Storage/12FC Host Bus Adapter Model No. L.18.02 or later Microsoft Windows 2000 Advanced Server SPU Model Clock speed No. HP D8602A ...
... HP cables that meet SCSI specifications and... arrays Required HP Fibre Channel Host Bus Adapter - of controllers Driver SPU I /O slots: HP NetServer LC 2000 733 MHz 2 4.06.20 PV or later Any size 256 MB minimum. Local...2000 Advanced Server. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any power conditioner or UPS. May not use embedded SCSI or NetRAID-1Si in PCI slot P1. Any Shared HP... Rack Storage/12FC Host Bus Adapter Model No. L.18.02 or later Microsoft Windows 2000 Advanced Server SPU Model Clock speed No. HP D8602A ...