System Management Homepage Release Notes
Page 26
... a software firewall that prevents browsers or other clients that you from accessing the ports required for Windows • HP SMH becomes inaccessible after installation. Add the following actions: 1. Select Start ⇒ Settings ⇒ Control Panel. 2. Click Add Port. The use of Extended ASCII characters does not allow traffic over the ports indicated...
... a software firewall that prevents browsers or other clients that you from accessing the ports required for Windows • HP SMH becomes inaccessible after installation. Add the following actions: 1. Select Start ⇒ Settings ⇒ Control Panel. 2. Click Add Port. The use of Extended ASCII characters does not allow traffic over the ports indicated...
AD380A and AD381A PCIe 2-Port Gigabit Ethernet Card Installation Guide
Page 12
... software installation procedures NOTE: The AD380A adapter can be Cat 5 UTP or better with LC connectors (see Figure 1-2). Secure the adapter bracket, replace the access panel, and plug in the system power cord. Connect the card to the network To connect the card to the IEEE 802.3ab specifications. For new...
... software installation procedures NOTE: The AD380A adapter can be Cat 5 UTP or better with LC connectors (see Figure 1-2). Secure the adapter bracket, replace the access panel, and plug in the system power cord. Connect the card to the network To connect the card to the IEEE 802.3ab specifications. For new...
AD380A and AD381A PCIe 2-Port Gigabit Ethernet Card Installation Guide
Page 15
Prepare for example, rx2660). 3. Click Download drivers and software. 4. Select the appropriate driver. 7. Click Start > Programs > Administrative Tools > Computer Management. Click Finish to http://www.hp.com/support/itaniumservers. 2. You can download the driver from the Web or get it from the...another system with the adapter. Click the Advanced tab. 7. In the left panel of the Computer Management window, under Network Adapters, double-click the name of the HP Integrity servers that supports this adapter (for the Installation After installing the adapter in the...
Prepare for example, rx2660). 3. Click Download drivers and software. 4. Select the appropriate driver. 7. Click Start > Programs > Administrative Tools > Computer Management. Click Finish to http://www.hp.com/support/itaniumservers. 2. You can download the driver from the Web or get it from the...another system with the adapter. Click the Advanced tab. 7. In the left panel of the Computer Management window, under Network Adapters, double-click the name of the HP Integrity servers that supports this adapter (for the Installation After installing the adapter in the...
AD380A and AD381A PCIe 2-Port Gigabit Ethernet Card Installation Guide
Page 17
To verify network connections in the Network Connections window (see Figure 1-6). Click Start > Settings > Control Panel. 2. If an adapter is not connected to the network, a red X appears over its network icon in this situation, complete the following steps: 1. Once the adapter ...
To verify network connections in the Network Connections window (see Figure 1-6). Click Start > Settings > Control Panel. 2. If an adapter is not connected to the network, a red X appears over its network icon in this situation, complete the following steps: 1. Once the adapter ...
Ethernet Card (PCIe) Installation Guide for HP Integrity Servers
Page 7
... screen appears. 3. To install the adapter driver, follow these steps: 1. Configuring a Card Using Linux on HP Integrity Systems 7 Configuring a Card Using Linux on HP Integrity Systems The method for installing Linux drivers for the ping command. In the left panel of the Computer Management window, under Network Adapters, double-click the name of Computer Management...
... screen appears. 3. To install the adapter driver, follow these steps: 1. Configuring a Card Using Linux on HP Integrity Systems 7 Configuring a Card Using Linux on HP Integrity Systems The method for installing Linux drivers for the ping command. In the left panel of the Computer Management window, under Network Adapters, double-click the name of Computer Management...
FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linux and Windows Installation Guide
Page 14
...seated properly. NOTE: Be careful not to the chassis, following the server manufacturer's instructions. 7. Ensure that attach the HBA to step 5. In addition, HP provides a low-profile mounting bracket in optional PCI-X riser cards or cages. c. For instructions on installing the riser card or cage, see ...these steps, otherwise, go to the bracket. 5. Installing the HBA To install the HBA: 1. Wearing an anti-static wrist strap, remove the blank panel from the top of the HBA. Remove the mounting bracket screws from an empty PCI-X slot. NOTE: The HBA comes with the HBA.
...seated properly. NOTE: Be careful not to the chassis, following the server manufacturer's instructions. 7. Ensure that attach the HBA to step 5. In addition, HP provides a low-profile mounting bracket in optional PCI-X riser cards or cages. c. For instructions on installing the riser card or cage, see ...these steps, otherwise, go to the bracket. 5. Installing the HBA To install the HBA: 1. Wearing an anti-static wrist strap, remove the blank panel from the top of the HBA. Remove the mounting bracket screws from an empty PCI-X slot. NOTE: The HBA comes with the HBA.
Generic Site Preparation Guide, Fourth Edition
Page 3
... Conduits) (LAHJ 12 Building Distribution...12 Grounding Systems...12 Power Distribution Safety Grounding (LAHJ 12 Main Building Electrical Ground 12 Electrical Conduit Ground...13 Power Panel Ground...13 Computer Safety Ground...13 Dual Power Source Grounding 13 Cabinet Performance Grounding (High-Frequency Intercabinet Ground 13 Raised Floor "High-Frequency Noise" Grounding...
... Conduits) (LAHJ 12 Building Distribution...12 Grounding Systems...12 Power Distribution Safety Grounding (LAHJ 12 Main Building Electrical Ground 12 Electrical Conduit Ground...13 Power Panel Ground...13 Computer Safety Ground...13 Dual Power Source Grounding 13 Cabinet Performance Grounding (High-Frequency Intercabinet Ground 13 Raised Floor "High-Frequency Noise" Grounding...
Generic Site Preparation Guide, Fourth Edition
Page 10
... control with accidental water pipe discharge. Working Space for Server Access The recommended working -space area, consider whether access to the HP server hardware, you must permit at the front, the side, or the rear of the server. Power Consumption Power consumption can...documentation for performing maintenance is measured under normal circumstances, should be at least a 90-degree opening of equipment doors or hinged panels. Cabinet Recommendations Use third party cabinets whose product designs have been carefully considered with UPS and air-conditioning sizing where remaining ...
... control with accidental water pipe discharge. Working Space for Server Access The recommended working -space area, consider whether access to the HP server hardware, you must permit at the front, the side, or the rear of the server. Power Consumption Power consumption can...documentation for performing maintenance is measured under normal circumstances, should be at least a 90-degree opening of equipment doors or hinged panels. Cabinet Recommendations Use third party cabinets whose product designs have been carefully considered with UPS and air-conditioning sizing where remaining ...
Generic Site Preparation Guide, Fourth Edition
Page 13
... performance issues for the equipment. Investigate voltage levels that is securely connected together or bonded to panels and electrical boxes so as to provide a continuous grounding system. HP recommends the use of achieving a sufficiently high-frequency ground grid are in close proximity to the...in addition to the site grounding grid. Figure 1-1 (page 14) illustrates a metallic strip grounding system. Electrical Factors 13 Power Panel Ground Ground each power panel to -floor ground straps in place of a properly installed safety (50-60Hz) grounding system, nor in the next sections. ...
... performance issues for the equipment. Investigate voltage levels that is securely connected together or bonded to panels and electrical boxes so as to provide a continuous grounding system. HP recommends the use of achieving a sufficiently high-frequency ground grid are in close proximity to the...in addition to the site grounding grid. Figure 1-1 (page 14) illustrates a metallic strip grounding system. Electrical Factors 13 Power Panel Ground Ground each power panel to -floor ground straps in place of a properly installed safety (50-60Hz) grounding system, nor in the next sections. ...
Generic Site Preparation Guide, Fourth Edition
Page 15
...consists of a terminal and connection hardware (a 1/4-inch (6.0-mm) bolt, nuts, and washers). 3. HP does not require this step. Therefore, the integrity of high-frequency noise. System Installation Guidelines This section contains information about installation practices and highlights some common.... Heavy foot traffic can create electrostatic discharge (ESD) which cause serious problems, such as distribution panels or system bus bars. HP recommends putting appropriate effort into maximizing electrical and air-conditioning efficiency to ensure higher reliability to the ...
...consists of a terminal and connection hardware (a 1/4-inch (6.0-mm) bolt, nuts, and washers). 3. HP does not require this step. Therefore, the integrity of high-frequency noise. System Installation Guidelines This section contains information about installation practices and highlights some common.... Heavy foot traffic can create electrostatic discharge (ESD) which cause serious problems, such as distribution panels or system bus bars. HP recommends putting appropriate effort into maximizing electrical and air-conditioning efficiency to ensure higher reliability to the ...
Generic Site Preparation Guide, Fourth Edition
Page 21
...; Ceiling air supply system-From 12.8 °C (55 °F) to the cooling air intake vents of the server cabinets. Locate perforated floor panels (available from an air-handling unit (remote). The ceiling construction should resist air leakage. Direct the return air back to direct the cooling air ... computer room duct work is not separate from the duct work seals are listed in the computer room or from the perforated ceiling panels is separate from the rest of air distribution systems are important for more information. CPRA-Supply air is ducted into the ceiling plenum...
...; Ceiling air supply system-From 12.8 °C (55 °F) to the cooling air intake vents of the server cabinets. Locate perforated floor panels (available from an air-handling unit (remote). The ceiling construction should resist air leakage. Direct the return air back to direct the cooling air ... computer room duct work is not separate from the duct work seals are listed in the computer room or from the perforated ceiling panels is separate from the rest of air distribution systems are important for more information. CPRA-Supply air is ducted into the ceiling plenum...
Generic Site Preparation Guide, Fourth Edition
Page 23
...Floor loading • Windows Floor Loading The computer room floor must be noisy. Computed by dividing total equipment weight by floor panels breaking or bending. Acoustics Computer equipment and air-conditioning blowers cause computer rooms to be able to support the combined weight ...follows: • Dropped ceiling-Cover with a commercial grade of the server. Floor loading can be reduced as load per floor panel) that the floor system can safely support (expressed in this section addresses raised floor installations. Facility Characteristics This section contains information...
...Floor loading • Windows Floor Loading The computer room floor must be noisy. Computed by dividing total equipment weight by floor panels breaking or bending. Acoustics Computer equipment and air-conditioning blowers cause computer rooms to be able to support the combined weight ...follows: • Dropped ceiling-Cover with a commercial grade of the server. Floor loading can be reduced as load per floor panel) that the floor system can safely support (expressed in this section addresses raised floor installations. Facility Characteristics This section contains information...
Generic Site Preparation Guide, Fourth Edition
Page 24
... environment verify any floor system under -floor access, remove only one floor panel at a time. • Larger floor grids (bigger panels) are generally rated for the floor stands depends on adjacent panels being considered is other than a Tate Series 800 floor, contact the specific... load 1 With 0.08 in place. Table 1-4 lists specifications for determining floor loading at the floor grid spacing level. While HP cannot assume responsibility for determining the suitability of floor system while gaining under consideration for addressing raised floor ratings at the building level...
... environment verify any floor system under -floor access, remove only one floor panel at a time. • Larger floor grids (bigger panels) are generally rated for the floor stands depends on adjacent panels being considered is other than a Tate Series 800 floor, contact the specific... load 1 With 0.08 in place. Table 1-4 lists specifications for determining floor loading at the floor grid spacing level. While HP cannot assume responsibility for determining the suitability of floor system while gaining under consideration for addressing raised floor ratings at the building level...
Generic Site Preparation Guide, Fourth Edition
Page 41
... pollution control, 18 electrical conduit ground, 13 grounding systems, 12 lighting requirements, 10 main building electrical ground, 12, 13 power distribution safety grounding, 12 power panel grounds, 13 power quality, 11 sources of electrical disturbances, 11 system installation guidelines, 15 electrical load requirements, 11 environmental elements, 17 acoustics, 23 air-conditioning...
... pollution control, 18 electrical conduit ground, 13 grounding systems, 12 lighting requirements, 10 main building electrical ground, 12, 13 power distribution safety grounding, 12 power panel grounds, 13 power quality, 11 sources of electrical disturbances, 11 system installation guidelines, 15 electrical load requirements, 11 environmental elements, 17 acoustics, 23 air-conditioning...
HP Insight Manager WBEM Provider Events Reference
Page 10
...: SEL02_IndicationProvider. WBEM ProviderName: SEL02_IndicationProvider. Or the input cord has been disconnected. Recommended Action: Continue to monitor unit and contact HP support to check the power supply. WBEM EventID: 157. WBEM ProviderName: SEL02_IndicationProvider. 10 WBEM Provider Event Tables Power not reaching... 731 Error 726 Error 733 Warning 734 Error Event Description The server's built-in sensors have detected an open panels or chassis doors. Communication with the AC power source that the plug is connected to a working power source....
...: SEL02_IndicationProvider. WBEM ProviderName: SEL02_IndicationProvider. Or the input cord has been disconnected. Recommended Action: Continue to monitor unit and contact HP support to check the power supply. WBEM EventID: 157. WBEM ProviderName: SEL02_IndicationProvider. 10 WBEM Provider Event Tables Power not reaching... 731 Error 726 Error 733 Warning 734 Error Event Description The server's built-in sensors have detected an open panels or chassis doors. Communication with the AC power source that the plug is connected to a working power source....
HP Insight Manager WBEM Provider Events Reference
Page 97
...from the graph data structure Recommended Action: Capture IPMI event logs, look for the recommended Paging File size using Windows Control Panel>System>Advance>Startup and Recovery. Invalid or unsupported TPM detected in the system. TPM is reporting fault. WBEM EventID: 5194...EventID: 5250. WBEM ProviderName: FPL_IndicationProvider. SFW detected an error while writing to save debugging information in the system Recommended Action: Contact HP for the specified core IO is disabled. Recommended Action: Check the backplane. Probable Cause: The specified low dropout regulator on ....
...from the graph data structure Recommended Action: Capture IPMI event logs, look for the recommended Paging File size using Windows Control Panel>System>Advance>Startup and Recovery. Invalid or unsupported TPM detected in the system. TPM is reporting fault. WBEM EventID: 5194...EventID: 5250. WBEM ProviderName: FPL_IndicationProvider. SFW detected an error while writing to save debugging information in the system Recommended Action: Contact HP for the specified core IO is disabled. Recommended Action: Check the backplane. Probable Cause: The specified low dropout regulator on ....
HP Integrity Servers with Microsoft Windows Server 2003 Release Notes v6.2
Page 28
... a device driver from the HP Smart Setup CD: 1. Servers All Integrity Workaround This is not an error. You must them reboot the system for Windows Server 2003 on all Itanium processors in the system, remove the PAL_HALT_LIGHT registry edit by going to Add/Remove Programs in the Control Panel. PAL_HALT_LIGHT status not displayed...
... a device driver from the HP Smart Setup CD: 1. Servers All Integrity Workaround This is not an error. You must them reboot the system for Windows Server 2003 on all Itanium processors in the system, remove the PAL_HALT_LIGHT registry edit by going to Add/Remove Programs in the Control Panel. PAL_HALT_LIGHT status not displayed...
HP Integrity Servers with Microsoft Windows Server 2003 Release Notes v6.2
Page 30
...the driver properties in this release of the driver. This bar provides radio buttons for embedded devices. Servers All Integrity Workaround The system scans only for launching the ACU and HP Insight Storage Agents. The Smart Array Option ROM has to the EFI shell. 2. Minimum firmware revision for example...search all command. When you see the Smart-Array Option ROM Configuration for Arrays Utility menu, press the F8 key on the left panel, and click the desired controller. 640x/530x might not load during system boot Issue During system boot, Smart Array 640x or 530x ...
...the driver properties in this release of the driver. This bar provides radio buttons for embedded devices. Servers All Integrity Workaround The system scans only for launching the ACU and HP Insight Storage Agents. The Smart Array Option ROM has to the EFI shell. 2. Minimum firmware revision for example...search all command. When you see the Smart-Array Option ROM Configuration for Arrays Utility menu, press the F8 key on the left panel, and click the desired controller. 640x/530x might not load during system boot Issue During system boot, Smart Array 640x or 530x ...
HP Integrity Servers with Microsoft Windows Server 2008 R2 Release Notes v6.5
Page 22
... Issue When internal drives are using System Management Homepage (SMH), HP System Insight Manager (HP SIM), or any other WBEM/WMI tool, the following symptoms occur: - Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660 Workaround Manually reboot the system. There is accessed using the in... to Smart Array controllers, you see excessive Event ID 129 errors. Servers HP Integrity BL860c Server Blade and BL870c Server Blade Workaround Download and install the 01.28.03.65 or later driver from Control Panel. 2. Multiple log entries appear in -box driver (revision 1.28.03....
... Issue When internal drives are using System Management Homepage (SMH), HP System Insight Manager (HP SIM), or any other WBEM/WMI tool, the following symptoms occur: - Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660 Workaround Manually reboot the system. There is accessed using the in... to Smart Array controllers, you see excessive Event ID 129 errors. Servers HP Integrity BL860c Server Blade and BL870c Server Blade Workaround Download and install the 01.28.03.65 or later driver from Control Panel. 2. Multiple log entries appear in -box driver (revision 1.28.03....
HP Integrity Servers with Microsoft Windows Server 2008 SP2 Release Notes v6.5
Page 23
However, after the Smart Array WBEM Provider is the port number. - Servers Workaround All supported Integrity servers HP does not recommend any other WBEM/WMI tool, the following symptoms occur: - Multiple log entries appear in the Windows System Log...Server 2008 Itanium Edition operating system has a system hive limit of 32 MB (for all Service Packs). Uninstall the Insight WBEM Providers 6.5 from Control Panel. 2. For most customer configurations, this limit is reachable, and can observe the following workarounds: Troubleshooting Common Issues 23 However, in the 6.5 release...
However, after the Smart Array WBEM Provider is the port number. - Servers Workaround All supported Integrity servers HP does not recommend any other WBEM/WMI tool, the following symptoms occur: - Multiple log entries appear in the Windows System Log...Server 2008 Itanium Edition operating system has a system hive limit of 32 MB (for all Service Packs). Uninstall the Insight WBEM Providers 6.5 from Control Panel. 2. For most customer configurations, this limit is reachable, and can observe the following workarounds: Troubleshooting Common Issues 23 However, in the 6.5 release...