Managing Your Remote Servers with HP iLO Advanced and LO100i Advanced
Page 1
... portfolio it offers a graphical or text-based console, automatic video recording, server power capping, and team collaboration capabilities. The only warranties for HP products and services are fully enabled. Additionally, iLO Advanced saves you are. Valid license from HP required for a specific system and enter the license key. 2. The information contained herein is more...
... portfolio it offers a graphical or text-based console, automatic video recording, server power capping, and team collaboration capabilities. The only warranties for HP products and services are fully enabled. Additionally, iLO Advanced saves you are. Valid license from HP required for a specific system and enter the license key. 2. The information contained herein is more...
HP ProLiant Essentials Rapid Deployment Pack-Windows Edition Support Matrix
Page 11
... continuous quality improvement, calls may be found in PDF format at http://www.hp.com/servers/rdp, from other locations, see the Contact HP worldwide webpage at http://www.hp.com/servers/rdp. • Regularly updated troubleshooting information, frequently asked questions, and specific how-to procedures are available in the IT Resource Center (ITRC) User Forum...
... continuous quality improvement, calls may be found in PDF format at http://www.hp.com/servers/rdp, from other locations, see the Contact HP worldwide webpage at http://www.hp.com/servers/rdp. • Regularly updated troubleshooting information, frequently asked questions, and specific how-to procedures are available in the IT Resource Center (ITRC) User Forum...
HP Version Control Release Notes
Page 14
...Server 2003 IMPORTANT: The disk space requirements previously mentioned are outlined. Hardware and software requirements • Operating system - Windows XP • Browser - This must be on the files contained in the VCRM installation drive for temporary ProLiant or Integrity Support Pack extraction - 2 GB for client access to the VCRM are specific... to the installation of ProLiant or Integrity Support Packs you are downloading multiple ProLiant or Integrity Support Packs, then...
...Server 2003 IMPORTANT: The disk space requirements previously mentioned are outlined. Hardware and software requirements • Operating system - Windows XP • Browser - This must be on the files contained in the VCRM installation drive for temporary ProLiant or Integrity Support Pack extraction - 2 GB for client access to the VCRM are specific... to the installation of ProLiant or Integrity Support Packs you are downloading multiple ProLiant or Integrity Support Packs, then...
HP Version Control Release Notes
Page 15
... copy items in the catalog. You can define their own site-specific security rules and configure their own proxy servers in the absence of the testing was with any subsequent uploads, ...select Support Pack, it . • If a ProLiant or Integrity Support Pack is uploaded from a system with Password Authentication Microsoft ISA server Yes Yes Microsoft ISA No Yes WinProxy NA Yes Wingate Yes ... least one VCA to the same VCRM. However, the copied components are using a proxy server. HP recommends that you should keep in that is complete. Perform an upload from a system using...
... copy items in the catalog. You can define their own site-specific security rules and configure their own proxy servers in the absence of the testing was with any subsequent uploads, ...select Support Pack, it . • If a ProLiant or Integrity Support Pack is uploaded from a system with Password Authentication Microsoft ISA server Yes Yes Microsoft ISA No Yes WinProxy NA Yes Wingate Yes ... least one VCA to the same VCRM. However, the copied components are using a proxy server. HP recommends that you should keep in that is complete. Perform an upload from a system using...
Version Control Release Notes
Page 14
... to determine how much disk space is approximately 100 MB in size and extracts to the VCRM are specific to the installation of ProLiant or Integrity Support Packs you can multiply this size by the number of the VCRM. Hardware and software requirements •... Vista • Browser • Internet Explorer 6.0 with Service Pack 1 or later • Server software • TCP/IP installed • SMH installed • Hardware • ProLiant Server • HP Business Desktops • Windows Integrity Servers • Disk space • 14-15 MB (Installation files only) • 200 MB...
... to determine how much disk space is approximately 100 MB in size and extracts to the VCRM are specific to the installation of ProLiant or Integrity Support Packs you can multiply this size by the number of the VCRM. Hardware and software requirements •... Vista • Browser • Internet Explorer 6.0 with Service Pack 1 or later • Server software • TCP/IP installed • SMH installed • Hardware • ProLiant Server • HP Business Desktops • Windows Integrity Servers • Disk space • 14-15 MB (Installation files only) • 200 MB...
Version Control Release Notes
Page 17
...auto-update process. • You cannot copy items in the testing of an Integrity Support Pack upgrade, a failed VCA installation event is performing the auto-update. ....sys drivers • CP003746 - This situation can define their own site-specific security rules and configure their own proxy servers in the VCRM 17 However, the copied components are affected include the following... • Auto-update appears to complete successfully, but no files are using CERN proxy, HP recommends configuring the VCRM to date, the following proxy applications were used in a VCRM repository...
...auto-update process. • You cannot copy items in the testing of an Integrity Support Pack upgrade, a failed VCA installation event is performing the auto-update. ....sys drivers • CP003746 - This situation can define their own site-specific security rules and configure their own proxy servers in the VCRM 17 However, the copied components are affected include the following... • Auto-update appears to complete successfully, but no files are using CERN proxy, HP recommends configuring the VCRM to date, the following proxy applications were used in a VCRM repository...
Ethernet Card (PCIe) Installation Guide for HP Integrity Servers
Page 3
... a Card Using Windows Server 2003 and Windows Server 2008 64-bit on HP Integrity Servers" (page 6) • "Configuring a Card Using Linux on HP Integrity Systems" (page 7) Operating Systems Supported on HP Integrity systems For additional information on using this card at : http://www.docs.hp.com/en/netcom.html Available documents include the following: • Product Overview, including specifications, regulatory statements...
... a Card Using Windows Server 2003 and Windows Server 2008 64-bit on HP Integrity Servers" (page 6) • "Configuring a Card Using Linux on HP Integrity Systems" (page 7) Operating Systems Supported on HP Integrity systems For additional information on using this card at : http://www.docs.hp.com/en/netcom.html Available documents include the following: • Product Overview, including specifications, regulatory statements...
BCS Global Limited Warranty and Technical Support, Fourth Edition
Page 10
... cost for these service upgrades, refer to the HP website at your site • Notify HP if products are in place, accessible, and legible • Maintain an environment consistent with product specifications and supported configurations Service upgrades HP has a range of additional support and service coverage... to the base hardware warranty might be included with your HP Hardware Product. Enhancements to upgrade your base hardware product warranty. In order to the HP website at http://www.hp.com. • If a server product is not covered in the tables that follow reflects base...
... cost for these service upgrades, refer to the HP website at your site • Notify HP if products are in place, accessible, and legible • Maintain an environment consistent with product specifications and supported configurations Service upgrades HP has a range of additional support and service coverage... to the base hardware warranty might be included with your HP Hardware Product. Enhancements to upgrade your base hardware product warranty. In order to the HP website at http://www.hp.com. • If a server product is not covered in the tables that follow reflects base...
Generic Site Preparation Guide, Fourth Edition
Page 7
... Synopsis AC Electrical Distribution System HP recommends use of voltage tolerances. As your business needs will vary from customer to customer and from higher distribution voltages. In an optimum electrical distribution system: • Electrical infrastructure is rated for the marked electrical-rated voltage. NOTE: See the specific server service guide for the guidelines...
... Synopsis AC Electrical Distribution System HP recommends use of voltage tolerances. As your business needs will vary from customer to customer and from higher distribution voltages. In an optimum electrical distribution system: • Electrical infrastructure is rated for the marked electrical-rated voltage. NOTE: See the specific server service guide for the guidelines...
Generic Site Preparation Guide, Fourth Edition
Page 8
...8226; Do not daisy chain phase, neutral, and ground wires. • If the system is 15 amperes (A) on a server, depending on raised flooring, use . Do not interchange them. • Do not use conduit grounds in place of a separate..., but realize that are compatible with present-day technology generally use pulse width modulation (PWM) and have specific uses. HP does not recommend the practice of the room, and develop a growth plan for the highest availability environment.... demanding high availability. Grounding Systems WARNING! This grounding is integral to the AC distribution point.
...8226; Do not daisy chain phase, neutral, and ground wires. • If the system is 15 amperes (A) on a server, depending on raised flooring, use . Do not interchange them. • Do not use conduit grounds in place of a separate..., but realize that are compatible with present-day technology generally use pulse width modulation (PWM) and have specific uses. HP does not recommend the practice of the room, and develop a growth plan for the highest availability environment.... demanding high availability. Grounding Systems WARNING! This grounding is integral to the AC distribution point.
Generic Site Preparation Guide, Fourth Edition
Page 9
... However, electrical factors relating to the geographic location (such as earthquake protection) Electrical Factors 9 Failure to region-specific or area-specific electrical codes and guidelines. Federal and local safety codes govern computer installations. Comprehensive Discussion IMPORTANT: Electrical practices and ...be considered during the site preparation process. For example, the recommendation that is beyond the scope of a server power distribution system requires specialized skills. Local authority has jurisdiction (LAHJ) and should exceed the requirements of personnel...
... However, electrical factors relating to the geographic location (such as earthquake protection) Electrical Factors 9 Failure to region-specific or area-specific electrical codes and guidelines. Federal and local safety codes govern computer installations. Comprehensive Discussion IMPORTANT: Electrical practices and ...be considered during the site preparation process. For example, the recommendation that is beyond the scope of a server power distribution system requires specialized skills. Local authority has jurisdiction (LAHJ) and should exceed the requirements of personnel...
Generic Site Preparation Guide, Fourth Edition
Page 10
... earthquake resistance can be divided into two broad categories: • Marked electrical amperage, which is listed on equipment or applicable product-specific documentation for Server Access The recommended working -space area, consider whether access to size the electrical infrastructure. • Typical consumption, which is measured ... valving with water as a backup system. Working Space for such devices to determine the power required to the HP server hardware, you must permit at 30 inches (76.2 cm) above the floor. Gaseous agents include CO2 and Halon substitutes, like Intergen....
... earthquake resistance can be divided into two broad categories: • Marked electrical amperage, which is listed on equipment or applicable product-specific documentation for Server Access The recommended working -space area, consider whether access to size the electrical infrastructure. • Typical consumption, which is measured ... valving with water as a backup system. Working Space for such devices to determine the power required to the HP server hardware, you must permit at 30 inches (76.2 cm) above the floor. Gaseous agents include CO2 and Halon substitutes, like Intergen....
Generic Site Preparation Guide, Fourth Edition
Page 11
...Breaker Sizing) IMPORTANT: Local authority has jurisdiction (LAHJ) must determine the final decision regarding adherence to comply with EMC Specification EN50082; Severe electrical disturbances can occur if these ranges are taken during power distribution system design to provide immunity to ... of their RMS current ratings. Electrical Factors 11 NOTE: Peripheral equipment should be considered if outages of one cycle. Power Quality HP servers operate over a wide range of these devices are recommended but optional. • Online UPS-Keeps input voltage to devices constant ...
...Breaker Sizing) IMPORTANT: Local authority has jurisdiction (LAHJ) must determine the final decision regarding adherence to comply with EMC Specification EN50082; Severe electrical disturbances can occur if these ranges are taken during power distribution system design to provide immunity to ... of their RMS current ratings. Electrical Factors 11 NOTE: Peripheral equipment should be considered if outages of one cycle. Power Quality HP servers operate over a wide range of these devices are recommended but optional. • Online UPS-Keeps input voltage to devices constant ...
Generic Site Preparation Guide, Fourth Edition
Page 24
... raised floor systems do not have carefully examined it is a function of the manufacturer's load specification and the positioning of a server. Raised Floor Loading Raised floor loading is adequate to support the HP installation. Table 1-4 lists specifications for a server installation. CAUTION: Do not position or install equipment cabinets on adjacent panels being considered is other...
... raised floor systems do not have carefully examined it is a function of the manufacturer's load specification and the positioning of a server. Raised Floor Loading Raised floor loading is adequate to support the HP installation. Table 1-4 lists specifications for a server installation. CAUTION: Do not position or install equipment cabinets on adjacent panels being considered is other...
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 3
Table of Contents About This Document...7 Intended Audience...7 New and Changed Information in This Edition 7 Publishing History...7 Document Organization...7 Typographic Conventions...8 Warranty Information...8 Related Information...8 HP Encourages Your Comments...9 1 Server Specifications...11 System Configuration...11 Dimensions and Weight...12 Grounding...12 Electrical Specifications...12 System Power Specifications...12 Power Consumption and Cooling 13 Physical and Environmental Specifications 13 Glossary...17 Index...19 Table of Contents 3
Table of Contents About This Document...7 Intended Audience...7 New and Changed Information in This Edition 7 Publishing History...7 Document Organization...7 Typographic Conventions...8 Warranty Information...8 Related Information...8 HP Encourages Your Comments...9 1 Server Specifications...11 System Configuration...11 Dimensions and Weight...12 Grounding...12 Electrical Specifications...12 System Power Specifications...12 Power Consumption and Cooling 13 Physical and Environmental Specifications 13 Glossary...17 Index...19 Table of Contents 3
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 7
... This document provides information and instructions for details. See your HP sales representative for preparing the site location when installing the HP Integrity rx2660 server. The latest version of this chapter to the appropriate product ...support service. The document printing date and part number indicate the document's current edition. Document updates may be made . To ensure that you receive the updated or new editions, you should subscribe to learn about the specifications...
... This document provides information and instructions for details. See your HP sales representative for preparing the site location when installing the HP Integrity rx2660 server. The latest version of this chapter to the appropriate product ...support service. The document printing date and part number indicate the document's current edition. Document updates may be made . To ensure that you receive the updated or new editions, you should subscribe to learn about the specifications...
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 11
... hard drives. Management core I /O Two GigE LAN ports. 1 Server Specifications This chapter provides the specifications for the HP Integrity rx2660 server. Disk drives PCI slots One to eight Double Data Rate 2 (DDR2) DIMMs mounted on the HP website at http://docs.hp.com System Configuration Table 1-1 lists the hardware specifications for the HP Integrity rx2660 server. This chapter addresses the following topics: • "System...
... hard drives. Management core I /O Two GigE LAN ports. 1 Server Specifications This chapter provides the specifications for the HP Integrity rx2660 server. Disk drives PCI slots One to eight Double Data Rate 2 (DDR2) DIMMs mounted on the HP website at http://docs.hp.com System Configuration Table 1-1 lists the hardware specifications for the HP Integrity rx2660 server. This chapter addresses the following topics: • "System...
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 12
... maximum dc power that is the worst case/highest current given the lowest input voltage and the maximum input power. 12 Server Specifications or Pedestal-Mounted Server Dimensions Dimensions and Weight Data Center Server Dimensions • Depth Value • 67.3 cm (26.5 in) • Width • 48.3 cm (19 in)...earth for each ac service entrance to the system. Dimensions and Weight Table 1-2 lists the dimensions and weight of the HP Integrity rx2660 Data Center server and the rx2660 Office Friendly server for the server. Electrical Specifications This section provides electrical...
... maximum dc power that is the worst case/highest current given the lowest input voltage and the maximum input power. 12 Server Specifications or Pedestal-Mounted Server Dimensions Dimensions and Weight Data Center Server Dimensions • Depth Value • 67.3 cm (26.5 in) • Width • 48.3 cm (19 in)...earth for each ac service entrance to the system. Dimensions and Weight Table 1-2 lists the dimensions and weight of the HP Integrity rx2660 Data Center server and the rx2660 Office Friendly server for the server. Electrical Specifications This section provides electrical...
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 14
.../300 meters (1000 feet) above 900 meters 3000 feet). Operating temperature and humidity ranges may vary depending on the installed mass storage devices. Table 1-5 Environmental Specifications (system processing unit with hard disk) Parameter Value Operating temperature +5˚ C to +35˚ C (+41˚ F to +95˚ F) Storage temperature - 40˚ .... High humidity levels can aggravate static electricity problems and cause excessive wear of memory. Table 1-6 (page 15) shows the physical and environmental specifications for the Data Center server. 14 Server Specifications
.../300 meters (1000 feet) above 900 meters 3000 feet). Operating temperature and humidity ranges may vary depending on the installed mass storage devices. Table 1-5 Environmental Specifications (system processing unit with hard disk) Parameter Value Operating temperature +5˚ C to +35˚ C (+41˚ F to +95˚ F) Storage temperature - 40˚ .... High humidity levels can aggravate static electricity problems and cause excessive wear of memory. Table 1-6 (page 15) shows the physical and environmental specifications for the Data Center server. 14 Server Specifications
Site Preparation Guide, Third Edition - HP Integrity rx2660 Server
Page 16
....8 (D 27.2 in W 10.8 in (with feet) W 5.0 in (w/o feet) H 20.0 in private slot. 1 Derate maximum dry bulb temperature 1 degree / 300 meters above 900 meters. 16 Server Specifications Table 1-7 Physical and Environmental Specifications of the Office Friendly Server Condition Typical Heat Release Nominal Airflow 100-127 VAC 200-240 VAC Maximum Airflow @ 35 degrees C1 Weight...
....8 (D 27.2 in W 10.8 in (with feet) W 5.0 in (w/o feet) H 20.0 in private slot. 1 Derate maximum dry bulb temperature 1 degree / 300 meters above 900 meters. 16 Server Specifications Table 1-7 Physical and Environmental Specifications of the Office Friendly Server Condition Typical Heat Release Nominal Airflow 100-127 VAC 200-240 VAC Maximum Airflow @ 35 degrees C1 Weight...