HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
... Version I14 05/17/2006 - Integrated Lights-Out Firmware 1.30 Jun 01 2007 Version HP BladeSystem Thermal Subsystem Name Thermal Subsystem-IT03-ENC-A - Bay Number 1 - Manufacturer HP - Integrated Lights-Out Name ILOUSM62500TE - Integrated Lights-Out Model iLO2 - Blade Type Workstation - Redundancy Redundant - Product Name ProLiant BL685c G1 - Server Name N/A HP BladeSystem Device Bay Name Device Bay...
... Version I14 05/17/2006 - Integrated Lights-Out Firmware 1.30 Jun 01 2007 Version HP BladeSystem Thermal Subsystem Name Thermal Subsystem-IT03-ENC-A - Bay Number 1 - Manufacturer HP - Integrated Lights-Out Name ILOUSM62500TE - Integrated Lights-Out Model iLO2 - Blade Type Workstation - Redundancy Redundant - Product Name ProLiant BL685c G1 - Server Name N/A HP BladeSystem Device Bay Name Device Bay...
ISS Technology Update Volume 8, Number 6
Page 1
... seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 77/c01891077.pdf Implementing Microsoft Windows Server 2008 R2 on HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c016395 ProLiant servers 94/c01639594.pdf...
... seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 77/c01891077.pdf Implementing Microsoft Windows Server 2008 R2 on HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c016395 ProLiant servers 94/c01639594.pdf...
ISS Technology Update, Volume 8, Number 2
Page 5
...and to interface with presales engineers at discerning promising technologies from 1991-94. For example, the ProLiant 8000 [first Compaq 8-processor server] and the DL585 G1 [first ProLiant Opteron-based server] were both significant products. I am proudest of our customers.‖ According to design and ...ended the same way...build it myself. An inventor at age 12 Name: Mitch Wright Title: Technologist/Sr. Engineer Years at HP. 5 I always worked with Mitch. Customer requirements are excerpts from 33MHz to solve our customers' problems, and he continually ...
...and to interface with presales engineers at discerning promising technologies from 1991-94. For example, the ProLiant 8000 [first Compaq 8-processor server] and the DL585 G1 [first ProLiant Opteron-based server] were both significant products. I am proudest of our customers.‖ According to design and ...ended the same way...build it myself. An inventor at age 12 Name: Mitch Wright Title: Technologist/Sr. Engineer Years at HP. 5 I always worked with Mitch. Customer requirements are excerpts from 33MHz to solve our customers' problems, and he continually ...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 1
HP ProLiant DL380 G5 Server 6 Case 2. HP ProLiant BL460c G1 and G5 Servers 7 Best Practices for Implementing Dynamic Power Capping 8 Setting Dynamic Power Caps for rack-mount servers 8 Setting Dynamic Power Cap with HP BladeSystem infrastructure 10 Conclusion...12 Appendix: TCO Test Configurations and Supported Servers 13 Test Configuration 1-HP ProLiant DL380 G5 Server 13 Test Configuration 2-HP ProLiant BL460c G1 Server 13 Test Configuration 3-HP ProLiant BL460c G5 Server 14 Supported Servers and Enclosures...14 For more information...
HP ProLiant DL380 G5 Server 6 Case 2. HP ProLiant BL460c G1 and G5 Servers 7 Best Practices for Implementing Dynamic Power Capping 8 Setting Dynamic Power Caps for rack-mount servers 8 Setting Dynamic Power Cap with HP BladeSystem infrastructure 10 Conclusion...12 Appendix: TCO Test Configurations and Supported Servers 13 Test Configuration 1-HP ProLiant DL380 G5 Server 13 Test Configuration 2-HP ProLiant BL460c G1 Server 13 Test Configuration 3-HP ProLiant BL460c G5 Server 14 Supported Servers and Enclosures...14 For more information...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 5
...will have their power caps increased. Blades running more effective power by spreading the Dynamic Power Cap across multiple servers.. The Dynamic Power Cap for each blade without impacting blade performance. Dynamic Power Capping TCO analysis This section ...: power supply faceplate, HP Power Calculator or HP BladeSystem Sizer, and Dynamic Power Capping. The first release of setting the Dynamic Power Cap for individual servers, the IT administrator sets a cap for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. The analysis compares the...
...will have their power caps increased. Blades running more effective power by spreading the Dynamic Power Cap across multiple servers.. The Dynamic Power Cap for each blade without impacting blade performance. Dynamic Power Capping TCO analysis This section ...: power supply faceplate, HP Power Calculator or HP BladeSystem Sizer, and Dynamic Power Capping. The first release of setting the Dynamic Power Cap for individual servers, the IT administrator sets a cap for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. The analysis compares the...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 7
..., an increase of 100%. For the ProLiant BL460c G5 server, the results are listed below (Tables 2 and 3). HP ProLiant BL460c G1 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power Capping Enclosure Power 7,836 W 6,000 W 4,790 W w/16 Blade Servers Maximum Number of 16 Blade Servers* 20 Blade Servers 28 Blade Servers Blade Servers and 1 Enclosure 2 Enclosures 2 Enclosures Enclosures...
..., an increase of 100%. For the ProLiant BL460c G5 server, the results are listed below (Tables 2 and 3). HP ProLiant BL460c G1 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power Capping Enclosure Power 7,836 W 6,000 W 4,790 W w/16 Blade Servers Maximum Number of 16 Blade Servers* 20 Blade Servers 28 Blade Servers Blade Servers and 1 Enclosure 2 Enclosures 2 Enclosures Enclosures...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 8
... is implemented within the enclosure peak and decline at different rates, setting a cap below . To begin using the ProLiant BL 460c G1 and G5 servers and the HP BladeSystem c7000 enclosure as the HP Power Calculator or HP BladeSystem Sizer to no performance loss. There is also a free trial for blades is still larger (32 blades for...
... is implemented within the enclosure peak and decline at different rates, setting a cap below . To begin using the ProLiant BL 460c G1 and G5 servers and the HP BladeSystem c7000 enclosure as the HP Power Calculator or HP BladeSystem Sizer to no performance loss. There is also a free trial for blades is still larger (32 blades for...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 10
...as our rack-mount example with your HP ProLiant server (see Appendix), the BladeSystem Sizer indicates that setting and adjusting Dynamic Power Caps should always be as short as a few important differences. Please note that 10 BL460 G1 servers will fit into two segments of ...servers): Table 6. Setting Dynamic Power Cap with HP BladeSystem infrastructure When setting a Dynamic Power Cap for list of blades that peak and idle concurrently. • First, download and apply the following updates to your facilities person, to the enclosure's application duty cycle. For the BL460c G1...
...as our rack-mount example with your HP ProLiant server (see Appendix), the BladeSystem Sizer indicates that setting and adjusting Dynamic Power Caps should always be as short as a few important differences. Please note that 10 BL460 G1 servers will fit into two segments of ...servers): Table 6. Setting Dynamic Power Cap with HP BladeSystem infrastructure When setting a Dynamic Power Cap for list of blades that peak and idle concurrently. • First, download and apply the following updates to your facilities person, to the enclosure's application duty cycle. For the BL460c G1...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 13
Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K ...Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power Calculator REV111601 Power measured using Voltech PM1000 Power Analyzer Test Configuration 2-HP ProLiant BL460c G1 Server 16 HP ProLiant BL460c G1 Servers 2 Intel® Xeon® Processor L5450 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF...
Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K ...Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power Calculator REV111601 Power measured using Voltech PM1000 Power Analyzer Test Configuration 2-HP ProLiant BL460c G1 Server 16 HP ProLiant BL460c G1 Servers 2 Intel® Xeon® Processor L5450 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 14
... Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers and Enclosures Dynamic Power Capping supported on the following servers and enclosures: HP BladeSystem c7000 enclosure HP ProLiant BL 2x220 G5 server HP ProLiant BL260 G5 server HP ProLiant BL460c G1 server HP ProLiant BL460c G5 server HP ProLiant BL495c G5 server HP ProLiant BL685 G5 server HP ProLiant DL360 G5 server HP ProLiant DL380 G5 server 14
... Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers and Enclosures Dynamic Power Capping supported on the following servers and enclosures: HP BladeSystem c7000 enclosure HP ProLiant BL 2x220 G5 server HP ProLiant BL260 G5 server HP ProLiant BL460c G1 server HP ProLiant BL460c G5 server HP ProLiant BL495c G5 server HP ProLiant BL685 G5 server HP ProLiant DL360 G5 server HP ProLiant DL380 G5 server 14
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 1
...HP ProLiant BL460c G1 and G5 Servers 7 Best Practices for Implementing Dynamic Power Capping 8 Setting Dynamic Power Caps for rack-mount servers 9 Setting Dynamic Power Cap with HP BladeSystem infrastructure 10 Conclusion...12 Appendix: TCO Test Configurations and Supported Servers 13 Test Configuration 1-HP ProLiant DL380 G5 Server 13 Test Configuration 2-HP ProLiant BL460c G1 Server 13 Test Configuration 3-HP ProLiant BL460c G5 Server 14 Supported Servers... The results of the data-gathering exercise appear in the following section 6 Case 1. HP ProLiant DL380 G5 Server 6 Case 2.
...HP ProLiant BL460c G1 and G5 Servers 7 Best Practices for Implementing Dynamic Power Capping 8 Setting Dynamic Power Caps for rack-mount servers 9 Setting Dynamic Power Cap with HP BladeSystem infrastructure 10 Conclusion...12 Appendix: TCO Test Configurations and Supported Servers 13 Test Configuration 1-HP ProLiant DL380 G5 Server 13 Test Configuration 2-HP ProLiant BL460c G1 Server 13 Test Configuration 3-HP ProLiant BL460c G5 Server 14 Supported Servers... The results of the data-gathering exercise appear in the following section 6 Case 1. HP ProLiant DL380 G5 Server 6 Case 2.
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 6
... capital cost recovery potential of the TCO analysis.4 Data for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. Faceplate value represents the maximum possible input power required for the DL380 G5 are listed below (Table 1). Generate Power Calculator/BladeSystem Sizer Estimates: HP Power Calculator and HP BladeSystem Sizer allow customers to generate load for the Dynamic Power...
... capital cost recovery potential of the TCO analysis.4 Data for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. Faceplate value represents the maximum possible input power required for the DL380 G5 are listed below (Table 1). Generate Power Calculator/BladeSystem Sizer Estimates: HP Power Calculator and HP BladeSystem Sizer allow customers to generate load for the Dynamic Power...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 7
... additional enclosure. In addition, while these measurements were calculated at 100% CPU utilization. Table 2. While customers who use faceplate as the BL460c G5 server and c7000 enclosure are even more than shown here. HP ProLiant BL460c G1 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power Capping Enclosure Power 7,836 W 6,000 W 4,790...
... additional enclosure. In addition, while these measurements were calculated at 100% CPU utilization. Table 2. While customers who use faceplate as the BL460c G5 server and c7000 enclosure are even more than shown here. HP ProLiant BL460c G1 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power Capping Enclosure Power 7,836 W 6,000 W 4,790...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 8
... on a circuit even when Dynamic Power Capping is still larger (32 blades for the BL460 G5 vs. 28 blades for the BL460 G1 vs. 23 servers for your HP servers is implemented within the enclosure peak and decline at the data in Circuit Power Provisioning $13,... Practices for Implementing Dynamic Power Capping Establishing the dynamic power capping settings for the DL380 G5). This takes you to the following URL, www.hp.com/go/ice and click buy online. HP ProLiant BL460c G5 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power ...
... on a circuit even when Dynamic Power Capping is still larger (32 blades for the BL460 G5 vs. 28 blades for the BL460 G1 vs. 23 servers for your HP servers is implemented within the enclosure peak and decline at the data in Circuit Power Provisioning $13,... Practices for Implementing Dynamic Power Capping Establishing the dynamic power capping settings for the DL380 G5). This takes you to the following URL, www.hp.com/go/ice and click buy online. HP ProLiant BL460c G5 Server Power and Costs Projections Faceplate Blade System Sizer (Enclosure) Load Testing and Dynamic Power ...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 13
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-...30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power Calculator REV111601 Power measured using Voltech PM1000 Power Analyzer Test Configuration 2-HP ProLiant BL460c G1 Server 16 HP ProLiant BL460c G1 Servers 2 Intel® Xeon® Processor L5450 4 4GB PC2-5300 DDR2 Fully Buffered ...
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-...30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power Calculator REV111601 Power measured using Voltech PM1000 Power Analyzer Test Configuration 2-HP ProLiant BL460c G1 Server 16 HP ProLiant BL460c G1 Servers 2 Intel® Xeon® Processor L5450 4 4GB PC2-5300 DDR2 Fully Buffered ...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 14
... Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers and Enclosures Dynamic Power Capping supported on the following servers and enclosures: HP BladeSystem c7000 enclosure HP ProLiant BL 2x220 G5 server HP ProLiant BL260 G5 server HP ProLiant BL460c G1 server HP ProLiant BL460c G5 server HP ProLiant BL495c G5 server HP ProLiant BL685 G5 server HP ProLiant DL360 G5 server HP ProLiant DL380 G5 server 14
... Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers and Enclosures Dynamic Power Capping supported on the following servers and enclosures: HP BladeSystem c7000 enclosure HP ProLiant BL 2x220 G5 server HP ProLiant BL260 G5 server HP ProLiant BL460c G1 server HP ProLiant BL460c G5 server HP ProLiant BL495c G5 server HP ProLiant BL685 G5 server HP ProLiant DL360 G5 server HP ProLiant DL380 G5 server 14
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 42
... " [0]>". System panics and reboots during installation • OS releases affected-Solaris 10 10/08, 5/09 • Servers affected-HP ProLiant DL485 G1, DL585 G1 • Description-System panics and reboots during installation after Smart Array Controller Driver is no native driver available for the ...NC362i Dual Port Gigabit Server Adapter in Solaris 10 5/08, 10/08, and 5/09. • Workaround-After OS ...
... " [0]>". System panics and reboots during installation • OS releases affected-Solaris 10 10/08, 5/09 • Servers affected-HP ProLiant DL485 G1, DL585 G1 • Description-System panics and reboots during installation after Smart Array Controller Driver is no native driver available for the ...NC362i Dual Port Gigabit Server Adapter in Solaris 10 5/08, 10/08, and 5/09. • Workaround-After OS ...