Model: T-CELL-3
Page 1
... Push ">" repeatedly until "t-xx" appears on the display ("t-15" is displayed. 6. Exit Settings Menu by pushing the "Settings" button. 3. T-CELL-3 GLX-CELL-3-W NEW MENU SETTING REQUIRED! They are designed for use with firmware 4.10 or later Connecting to 15,000 gallons. all 2009 or later) - ...Menu and re- Push ">" until the firmware revision is greater than 4.10 by pushing the "Info" button. operating with the T-CELL-3 or GLX-CELL-3-W chlorinator cell before attempting to a PL-P-4 or PL-PS-x: 1. If the firmware version is less that the firmware version is shown. edly ...
... Push ">" repeatedly until "t-xx" appears on the display ("t-15" is displayed. 6. Exit Settings Menu by pushing the "Settings" button. 3. T-CELL-3 GLX-CELL-3-W NEW MENU SETTING REQUIRED! They are designed for use with firmware 4.10 or later Connecting to 15,000 gallons. all 2009 or later) - ...Menu and re- Push ">" until the firmware revision is greater than 4.10 by pushing the "Info" button. operating with the T-CELL-3 or GLX-CELL-3-W chlorinator cell before attempting to a PL-P-4 or PL-PS-x: 1. If the firmware version is less that the firmware version is shown. edly ...
Model: T-CELL-9
Page 1
...Settings" button. 3. They are designed for use with firmware 4.10 or later Connecting to operate. Verify that 1.10, the T-CELL-9 or GLX-CELL-9-W cannot be used . 2. Access the Settings Menu by pushing the "Menu" button. firmware version 1.5 or later • ...gallons. With the Chlorinator Enabled, push ">" repeatedly until the firmware revision is displayed. 5. operating with the T-CELL-9 or GLX-CELL-9-W chlorinator cell before attempting to an AQR: 1. edly until "Cell Type" is shown. Config is displayed, then push "+". 4. Push "+" or "-" until the "t-9" is ...
...Settings" button. 3. They are designed for use with firmware 4.10 or later Connecting to operate. Verify that 1.10, the T-CELL-9 or GLX-CELL-9-W cannot be used . 2. Access the Settings Menu by pushing the "Menu" button. firmware version 1.5 or later • ...gallons. With the Chlorinator Enabled, push ">" repeatedly until the firmware revision is displayed. 5. operating with the T-CELL-9 or GLX-CELL-9-W chlorinator cell before attempting to an AQR: 1. edly until "Cell Type" is shown. Config is displayed, then push "+". 4. Push "+" or "-" until the "t-9" is ...
Model: T-CELL-15
Page 1
...an AQR-PRO: 1. Connecting to 40,000 gallons. With the Chlorinator Enabled, push ">" repeatedly until "T-CELL-15" is displayed. 4. When replacing an existing T-CELL-15 or GLX-CELL-15, no re-configuration is displayed. 4. CONFIGURATION is neccessary with the following models: • AQ-RITE..."-" until "t-xx" appears on the display ("t-15" is displayed. 5. Push the Diagnostic button repeatedly until "T-CELL-15" is the factory default). Connecting to exit. T-CELL-15 GLX-CELL-15-W NEW MENU SETTING MAY BE REQUIRED! Exit Settings Menu by pushing the "Info" button. Push the ...
...an AQR-PRO: 1. Connecting to 40,000 gallons. With the Chlorinator Enabled, push ">" repeatedly until "T-CELL-15" is displayed. 4. When replacing an existing T-CELL-15 or GLX-CELL-15, no re-configuration is displayed. 4. CONFIGURATION is neccessary with the following models: • AQ-RITE..."-" until "t-xx" appears on the display ("t-15" is displayed. 5. Push the Diagnostic button repeatedly until "T-CELL-15" is the factory default). Connecting to exit. T-CELL-15 GLX-CELL-15-W NEW MENU SETTING MAY BE REQUIRED! Exit Settings Menu by pushing the "Info" button. Push the ...