Quick Specs
Page 1
... locally approved piping should be used if installing under a poured concrete slab. PP989SN GE Profile™ 30" Downdraft Electric Cooktop Dimensions and Installation Information KW Rating 240V 9.1 Wall Installation: Wall installations require 25" countertop depth. Island or peninsula cabinets may require adjustment in back of cabinet. Duct hole is suggested. Installation Information: Before installing, consult installation instructions, packed with unit. Peninsula or Island...
... locally approved piping should be used if installing under a poured concrete slab. PP989SN GE Profile™ 30" Downdraft Electric Cooktop Dimensions and Installation Information KW Rating 240V 9.1 Wall Installation: Wall installations require 25" countertop depth. Island or peninsula cabinets may require adjustment in back of cabinet. Duct hole is suggested. Installation Information: Before installing, consult installation instructions, packed with unit. Peninsula or Island...
Quick Specs
Page 2
... both. Listed by Underwriters Laboratories Specification Created 7/08 220978 PP989SN GE Profile™ 30" Downdraft Electric Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in inches. PVC duct...installing under a poured concrete slab. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Laundry-type wall caps should be used. Note: Ductwork must be vented to outside. For satisfactory performance the duct run possible, with damper. Local building code must be followed in installation instructions...
... both. Listed by Underwriters Laboratories Specification Created 7/08 220978 PP989SN GE Profile™ 30" Downdraft Electric Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in inches. PVC duct...installing under a poured concrete slab. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Laundry-type wall caps should be used. Note: Ductwork must be vented to outside. For satisfactory performance the duct run possible, with damper. Local building code must be followed in installation instructions...
Use and Care Manual
Page 1
Radiant Downdraft Cooktop GEAppliances.com Safety Instructions 2-5 Operating Instructions Bridge Burner 8 Cooktop Vent System 8 Cookware Tips 9 Dual Surface Unit 8 Features of Your Cooktop 6 Surface Units 7, 8 Temperature Limiter 8 Care and Cleaning Control Knobs 10 Glass Cooktop 11, 12 Vent Filter and Chamber 10 Vent System 10 Installation Instructions Ductwork 17-20, 24 Electrical Connections 24-26 Exhaust Blower Ratings 19 Final Assembly...
Radiant Downdraft Cooktop GEAppliances.com Safety Instructions 2-5 Operating Instructions Bridge Burner 8 Cooktop Vent System 8 Cookware Tips 9 Dual Surface Unit 8 Features of Your Cooktop 6 Surface Units 7, 8 Temperature Limiter 8 Care and Cleaning Control Knobs 10 Glass Cooktop 11, 12 Vent Filter and Chamber 10 Vent System 10 Installation Instructions Ductwork 17-20, 24 Electrical Connections 24-26 Exhaust Blower Ratings 19 Final Assembly...
Use and Care Manual
Page 2
...in accordance with your downdraft cooktop unless it . 2. To reduce the risk of a COOKtop grease fire: A. Ducted fans must be locked, securely fasten a prominent warning device, such as those published by NFPA. WARNING - IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY ... use only metal ductwork. ■ Do not attempt to the outdoors. WARNING - Installation work and electrical wiring must be burned. B. Sufficient air is specifically recommended in the event of fire, electric shock or injury to an exit. * Based on low or medium settings. C....
...in accordance with your downdraft cooktop unless it . 2. To reduce the risk of a COOKtop grease fire: A. Ducted fans must be locked, securely fasten a prominent warning device, such as those published by NFPA. WARNING - IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY ... use only metal ductwork. ■ Do not attempt to the outdoors. WARNING - Installation work and electrical wiring must be burned. B. Sufficient air is specifically recommended in the event of fire, electric shock or injury to an exit. * Based on low or medium settings. C....
Use and Care Manual
Page 3
... not be left alone or unattended in an area where an appliance is properly installed and grounded by covering the pan completely with local codes and the provided installation instructions. ■ Have the installer show you the location of life. Do not let pot holders touch hot surface... items could be followed to minimize the risk of fire or explosion, electric shock, or to climb, stand or hang on the cooktop. ■ CAUTION: Items of 180°F. SAVE THESE INSTRUCTIONS 3 READ ALL INSTRUCTIONS BEFORE USING. GEAppliances.com WARNING! Flammable material could be put out by...
... not be left alone or unattended in an area where an appliance is properly installed and grounded by covering the pan completely with local codes and the provided installation instructions. ■ Have the installer show you the location of life. Do not let pot holders touch hot surface... items could be followed to minimize the risk of fire or explosion, electric shock, or to climb, stand or hang on the cooktop. ■ CAUTION: Items of 180°F. SAVE THESE INSTRUCTIONS 3 READ ALL INSTRUCTIONS BEFORE USING. GEAppliances.com WARNING! Flammable material could be put out by...
Use and Care Manual
Page 13
...tag, to the service panel. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 13 Installation Instructions Radiant Downdraft Cooktop If you have questions, call 800.GE.CARES (800.432.2737) or visit our Website at the service panel and lock the service ... OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A Installation work and electrical wiring must be locked, securely fasten a prominent warning device, such as those published by qualified person(s) in the installation of this product, engage a professional installer. • Proper installation is needed for...
...tag, to the service panel. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 13 Installation Instructions Radiant Downdraft Cooktop If you have questions, call 800.GE.CARES (800.432.2737) or visit our Website at the service panel and lock the service ... OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A Installation work and electrical wiring must be locked, securely fasten a prominent warning device, such as those published by qualified person(s) in the installation of this product, engage a professional installer. • Proper installation is needed for...
Use and Care Manual
Page 14
... Foam Gasket Tape CAUTION: DO NOT LIFT FROM VENT OPENING or bump glass C AUTION: GLASS IS FRAGILE DO NOT BUMP EDGE OF GLASS DURING INSTALLATION Blower Assembly and (4) Mounting Nuts (10-32 keps - Installation Instructions UNPACKING YOUR COOKTOP Parts Included (packed below the cooktop) • Blower assembly • Blower plenum • (4) Nuts (10-32 keps -
... Foam Gasket Tape CAUTION: DO NOT LIFT FROM VENT OPENING or bump glass C AUTION: GLASS IS FRAGILE DO NOT BUMP EDGE OF GLASS DURING INSTALLATION Blower Assembly and (4) Mounting Nuts (10-32 keps - Installation Instructions UNPACKING YOUR COOKTOP Parts Included (packed below the cooktop) • Blower assembly • Blower plenum • (4) Nuts (10-32 keps -
Use and Care Manual
Page 15
... listed in these Installation Instructions, and connected to the outside! 15 When installing an electric range in new construction, follow the instructions in wiring. CAUTION: FOR PERSONAL SAFETY, REMOVE HOUSE FUSE OR CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION. Installation Instructions PREPARATION Tools and ... properly installed connectors approved for use a three-wire, single-phase AC 208Y/120 Volt or 240/120 Volt, 60 Hertz electrical system with aluminum wiring must be used. 30" Cooktop (Dimensions for governing electrical codes and ordinances. Electrical requirements This...
... listed in these Installation Instructions, and connected to the outside! 15 When installing an electric range in new construction, follow the instructions in wiring. CAUTION: FOR PERSONAL SAFETY, REMOVE HOUSE FUSE OR CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION. Installation Instructions PREPARATION Tools and ... properly installed connectors approved for use a three-wire, single-phase AC 208Y/120 Volt or 240/120 Volt, 60 Hertz electrical system with aluminum wiring must be used. 30" Cooktop (Dimensions for governing electrical codes and ordinances. Electrical requirements This...
Use and Care Manual
Page 16
... the unit. Installation Instructions CABINET PREPARATION 1 PREPARING FOR INSTALLATION Positioning the cooktop The cooktop is designed to look best when centered in order to reduce the hazards caused by installing a range hood that the ductwork may be kept from countertop to local electrical codes. Preparing ... may need to nearest cabinet on either side of unprotected overhead cabinets 30" min. If the clearance between the cooktop and the cabinetry is used above the cooktop, allow a minimum 30" clearance between side edges of any unprotected cabinet. At least 6≤...
... the unit. Installation Instructions CABINET PREPARATION 1 PREPARING FOR INSTALLATION Positioning the cooktop The cooktop is designed to look best when centered in order to reduce the hazards caused by installing a range hood that the ductwork may be kept from countertop to local electrical codes. Preparing ... may need to nearest cabinet on either side of unprotected overhead cabinets 30" min. If the clearance between the cooktop and the cabinetry is used above the cooktop, allow a minimum 30" clearance between side edges of any unprotected cabinet. At least 6≤...
Use and Care Manual
Page 17
...opening for Ductwork NOTE: Ductwork MUST be vented to accommodate the cooktop and the vent. Installation Instructions CABINET PREPARATION Cutouts 4 Preparing the Countertop The countertop must be level and sit squarely into countertop opening. The cooktop unit must have a deep flat surface to outside. Be ... the corrugation as much of flexible ducting is available at your installation. Cut hole in the illustration. However, if the blower outlet and the floor or wall duct location do not damage electrical wiring and other and the rear exactly perpendicular to the sides....
...opening for Ductwork NOTE: Ductwork MUST be vented to accommodate the cooktop and the vent. Installation Instructions CABINET PREPARATION Cutouts 4 Preparing the Countertop The countertop must be level and sit squarely into countertop opening. The cooktop unit must have a deep flat surface to outside. Be ... the corrugation as much of flexible ducting is available at your installation. Cut hole in the illustration. However, if the blower outlet and the floor or wall duct location do not damage electrical wiring and other and the rear exactly perpendicular to the sides....
Use and Care Manual
Page 18
...and reflect requirements for the "Number Used" of straight duct used , all other duct pieces for good venting performance with any downdraft cooktop. †M easure and list feet of each type. x ( ) = ft. 31⁄4" x 10" to 31⁄.... Count and list the quantity of all the equivalent feet values in the table should not exceed 100 feet equivalent length. 18 Installation Instructions Ductwork calculations Calculate Total Equivalent Ductwork Length Duct Pieces Equivalent Length* x Number Used = Equivalent Length 5" round straight 2.7 ft. x ...
...and reflect requirements for the "Number Used" of straight duct used , all other duct pieces for good venting performance with any downdraft cooktop. †M easure and list feet of each type. x ( ) = ft. 31⁄4" x 10" to 31⁄.... Count and list the quantity of all the equivalent feet values in the table should not exceed 100 feet equivalent length. 18 Installation Instructions Ductwork calculations Calculate Total Equivalent Ductwork Length Duct Pieces Equivalent Length* x Number Used = Equivalent Length 5" round straight 2.7 ft. x ...
Use and Care Manual
Page 19
Installation Instructions EXHAUST BLOWER RATINGS Exhaust Blower Safety Warning Sufficient air is needed for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. 19 Follow the heating equipment manufacturer's guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for proper combustion and exhausting of gases through the flue (chimney) of other fuel burning equipment to prevent back drafting.
Installation Instructions EXHAUST BLOWER RATINGS Exhaust Blower Safety Warning Sufficient air is needed for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. 19 Follow the heating equipment manufacturer's guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for proper combustion and exhausting of gases through the flue (chimney) of other fuel burning equipment to prevent back drafting.
Use and Care Manual
Page 20
Installation Instructions Ductwork installation (Note: For planning purposes only.) 7 Installing the Ductwork Use galvanized or aluminum duct in 6≤ round or 31⁄4" x 10" size, or a combination of airflow as shown above. PVC duct should... Roof Direct to the "DUCTWORK CALCULATIONS" chart for equivalent lengths. Rotate blower and reinstall to calculate the total equivalent length of ALL duct used if installing under a poured concrete slab. screw Use the shortest and straightest duct run should NEVER be used . Secure all joints with damper. Use this chart ...
Installation Instructions Ductwork installation (Note: For planning purposes only.) 7 Installing the Ductwork Use galvanized or aluminum duct in 6≤ round or 31⁄4" x 10" size, or a combination of airflow as shown above. PVC duct should... Roof Direct to the "DUCTWORK CALCULATIONS" chart for equivalent lengths. Rotate blower and reinstall to calculate the total equivalent length of ALL duct used if installing under a poured concrete slab. screw Use the shortest and straightest duct run should NEVER be used . Secure all joints with damper. Use this chart ...
Use and Care Manual
Page 21
...the foam tape around the outer edge of the glass only on the bottom side of the cooktop glass as shown. Installation Instructions UNPACKING THE COOKTOP/INSTALLING THE GASKET 8 Installing the Foam Gasket Do not install the cooktop into the countertop without stretching. • M itre cut outside corners of foam gasket tape... to provide level support CAUTION: Glass is installed or it under the shipping pad to Glass Edge • Do not scratch the glass while cutting the foam gasket tape. 21 Remove the shipping block from the downdraft vent opening and place it will not stay in...
...the foam tape around the outer edge of the glass only on the bottom side of the cooktop glass as shown. Installation Instructions UNPACKING THE COOKTOP/INSTALLING THE GASKET 8 Installing the Foam Gasket Do not install the cooktop into the countertop without stretching. • M itre cut outside corners of foam gasket tape... to provide level support CAUTION: Glass is installed or it under the shipping pad to Glass Edge • Do not scratch the glass while cutting the foam gasket tape. 21 Remove the shipping block from the downdraft vent opening and place it will not stay in...
Use and Care Manual
Page 22
.... Glass is fragile-do not allow it into position. Align optional installation bracket under cooktop. Installation Instructions INstalling the cooktop 9 Installing the Cooktop CAUTION: Do not lift from the underside and lower slowly. Cooktop Optional installation bracket and thumbscrew (not included) Countertop Screws supplied with cooktop Thumbscrew To order optional installation brackets/thumbscrews, call the National Parts Center at the countertop surface.
.... Glass is fragile-do not allow it into position. Align optional installation bracket under cooktop. Installation Instructions INstalling the cooktop 9 Installing the Cooktop CAUTION: Do not lift from the underside and lower slowly. Cooktop Optional installation bracket and thumbscrew (not included) Countertop Screws supplied with cooktop Thumbscrew To order optional installation brackets/thumbscrews, call the National Parts Center at the countertop surface.
Use and Care Manual
Page 23
... the four threaded studs on the side of the cooktop, fasten the blower assembly securely to the plenum. NOTE: See Step 14 for installing the transition duct to the bottom of the cooktop, on the side of the cooktop. Install 4 screws Secure the plenum to the blower. Push...snap the plenum into place. (You may be easier to install the transition duct to the blower before installing the blower to the plenum with the blower opening in the bottom of the plenum. Installation Instructions INstalling the cooktop 12 INstalling the blower plenum to match the ductwork in Steps 6 ...
... the four threaded studs on the side of the cooktop, fasten the blower assembly securely to the plenum. NOTE: See Step 14 for installing the transition duct to the bottom of the cooktop, on the side of the cooktop. Install 4 screws Secure the plenum to the blower. Push...snap the plenum into place. (You may be easier to install the transition duct to the blower before installing the blower to the plenum with the blower opening in the bottom of the plenum. Installation Instructions INstalling the cooktop 12 INstalling the blower plenum to match the ductwork in Steps 6 ...
Use and Care Manual
Page 24
Installation Instructions INstalling the cooktop 14 Attaching A Blower Transition Duct Use a blower transition duct for reinstallation later. 5-pin connectors Electrical enclosure Flexible conduit Remove screws and discard strap 24 Install the transition duct to the blower transition duct. 16 BLOWER Electrical connections • Loosen ... in the blower outlet. Secure the enclosure with duct tape to assure an airtight seal. Fold all downward duct installations to connect to 6" round standard ductwork. This 31⁄4" x 10" rectangle to 6≤ round transition duct is...
Installation Instructions INstalling the cooktop 14 Attaching A Blower Transition Duct Use a blower transition duct for reinstallation later. 5-pin connectors Electrical enclosure Flexible conduit Remove screws and discard strap 24 Install the transition duct to the blower transition duct. 16 BLOWER Electrical connections • Loosen ... in the blower outlet. Secure the enclosure with duct tape to assure an airtight seal. Fold all downward duct installations to connect to 6" round standard ductwork. This 31⁄4" x 10" rectangle to 6≤ round transition duct is...
Use and Care Manual
Page 25
...Verify with this appliance are UL-recognized for connection to large gauge household wiring. Note: Do not install the cooktop without having to disconnect the wiring. Follow the connector manufacturer's recommended procedure closely. be ordered separately ...Installation Instructions ELECTRICAL CONNECTIONS 17 BEFORE MAKING ELECTRICAL CONNECTIONS Note to Electrician: The power leads supplied with product rating plate. Bushing (Fully Seated) Feed the leads through an antishort bushing and firmly seat the bushing in the wires to the cooktop so that the cooktop can be installed...
...Verify with this appliance are UL-recognized for connection to large gauge household wiring. Note: Do not install the cooktop without having to disconnect the wiring. Follow the connector manufacturer's recommended procedure closely. be ordered separately ...Installation Instructions ELECTRICAL CONNECTIONS 17 BEFORE MAKING ELECTRICAL CONNECTIONS Note to Electrician: The power leads supplied with product rating plate. Bushing (Fully Seated) Feed the leads through an antishort bushing and firmly seat the bushing in the wires to the cooktop so that the cooktop can be installed...
Use and Care Manual
Page 26
... to each other . When installing an electric range in new construction, follow the instructions in existing construction built prior to January 1, 1996, and if permitted by local codes: 3-Conductor Branch Circuit When connecting cooktop to a 3-conductor circuit, connect the red leads of the cooktop and the power supply to an electric range. connect the black leads...
... to each other . When installing an electric range in new construction, follow the instructions in existing construction built prior to January 1, 1996, and if permitted by local codes: 3-Conductor Branch Circuit When connecting cooktop to a 3-conductor circuit, connect the red leads of the cooktop and the power supply to an electric range. connect the black leads...
Use and Care Manual
Page 27
Check Operation of Downdraft • Turn the vent fan speed control to HI, MED and LO to make sure all speeds operate correctly. 27 Installation Instructions final assembly 20 Install DOWNDRAFT Filter and Vent Grille Do not operate the vent without the filter in the vent opening. • Carefully place the vent grille onto the downdraft opening . Vent Filter Vent Chamber • Make sure it rests, at an angle, on the supports in place. • Place the filter diagonally through the vent opening .
Check Operation of Downdraft • Turn the vent fan speed control to HI, MED and LO to make sure all speeds operate correctly. 27 Installation Instructions final assembly 20 Install DOWNDRAFT Filter and Vent Grille Do not operate the vent without the filter in the vent opening. • Carefully place the vent grille onto the downdraft opening . Vent Filter Vent Chamber • Make sure it rests, at an angle, on the supports in place. • Place the filter diagonally through the vent opening .