Quick Specs
Page 1
... Monogram,® Cafe™ Series, Profile™ Series or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. listed 20-amp power cord to the outside. Tested for natural gas. This appliance is... LP gas supply requires a conversion kit. This appliance is equipped with the product. Power cord should be purchased separately. Factory equipped for LP gas. Gas Requirements: GUD27GSSJ Gas Dryer - GUD27ESSJ/27GSSJ GE® 27" Unitized Spacemaker® 3.2 DOE Cu. Note: These appliances are not...
... Monogram,® Cafe™ Series, Profile™ Series or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. listed 20-amp power cord to the outside. Tested for natural gas. This appliance is... LP gas supply requires a conversion kit. This appliance is equipped with the product. Power cord should be purchased separately. Factory equipped for LP gas. Gas Requirements: GUD27GSSJ Gas Dryer - GUD27ESSJ/27GSSJ GE® 27" Unitized Spacemaker® 3.2 DOE Cu. Note: These appliances are not...
Installation Instructions
Page 1
... DUCT (IF NEEDED.) 4" COVER PLATE (IF NEEDED) (KIT WE1M454) DUCT TAPE EXHAUST HOOD GLOVES SAFETY GLASSES 3/4" STRAIN RELIEF UL RECOGNIZED APPLIANCE POWER CORD KIT (NOT PROVIDED) UL RATED 120/240V,30A WITH 3 OR 4 PRONGS. Save these instructions and in accordance with the instructions found in any...DEOH7LH 2 Washer Hoses 2 Rubber Washers 6WDLQHU6FUHHQV Rubber Washers ZDVKHUVPD\EHLQZDWHUKRVHV 233D1835P004 31-16728 12-14 GE Printed in the appliance. In Canada, call 800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN Read these instructions with your responsibility...
... DUCT (IF NEEDED.) 4" COVER PLATE (IF NEEDED) (KIT WE1M454) DUCT TAPE EXHAUST HOOD GLOVES SAFETY GLASSES 3/4" STRAIN RELIEF UL RECOGNIZED APPLIANCE POWER CORD KIT (NOT PROVIDED) UL RATED 120/240V,30A WITH 3 OR 4 PRONGS. Save these instructions and in accordance with the instructions found in any...DEOH7LH 2 Washer Hoses 2 Rubber Washers 6WDLQHU6FUHHQV Rubber Washers ZDVKHUVPD\EHLQZDWHUKRVHV 233D1835P004 31-16728 12-14 GE Printed in the appliance. In Canada, call 800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN Read these instructions with your responsibility...
Installation Instructions
Page 2
.... ELECTRICAL REQUIREMENTS CAUTION: %HIRUHSOXJJLQJLQZDVKHUUHDGWKHIROORZLQJ electrical requirements. CAUTION: For personal safety, do not use an extension cord or adapter plug with the voltage DQG IUHTXHQF\ LQGLFDWHG RQ WKH UDWLQJ SODWH ORFDWHG DW WKH WRSRIWKH... This appliance should be supplied with this appliance. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. Standpipe PXVWEHLQFKHVPLQLPXPLQVLGHGLDPHWHUDQGPXVWEH open to the Desired Location. 6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ ...
.... ELECTRICAL REQUIREMENTS CAUTION: %HIRUHSOXJJLQJLQZDVKHUUHDGWKHIROORZLQJ electrical requirements. CAUTION: For personal safety, do not use an extension cord or adapter plug with the voltage DQG IUHTXHQF\ LQGLFDWHG RQ WKH UDWLQJ SODWH ORFDWHG DW WKH WRSRIWKH... This appliance should be supplied with this appliance. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. Standpipe PXVWEHLQFKHVPLQLPXPLQVLGHGLDPHWHUDQGPXVWEH open to the Desired Location. 6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ ...
Installation Instructions
Page 5
... FRUG LV XQSOXJJHG IURP WKH ZDOO receptacle. 5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN 4. Properly secure power cord to an electric dryer. Grounding through the neutral conductor is prohibited. Keep the green ground screw for the new branch-circuit installations, mobile ...STRAIN RELIEF BRACKET NEUTRAL (White) HOT WIRE 3/4", UL RECOGNIZED STRAIN RELIEF COVER 4 #10 AWG MINIMUM COPPER CONDUCTORS OR 120/240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS & PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS (NOT SUPPLIED). 7XUQ RȺ ...
... FRUG LV XQSOXJJHG IURP WKH ZDOO receptacle. 5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN 4. Properly secure power cord to an electric dryer. Grounding through the neutral conductor is prohibited. Keep the green ground screw for the new branch-circuit installations, mobile ...STRAIN RELIEF BRACKET NEUTRAL (White) HOT WIRE 3/4", UL RECOGNIZED STRAIN RELIEF COVER 4 #10 AWG MINIMUM COPPER CONDUCTORS OR 120/240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS & PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS (NOT SUPPLIED). 7XUQ RȺ ...
Installation Instructions
Page 6
...end of each section of duct must point away from the dryer. • Do not assemble the ductwork with the opening pointed down. Properly secure power cord to the outer screws of 90º Elbows 0 1 2 4" Rigid Metal 43 Feet 33 Feet 24 Feet 2-1/2" Rigid Metal 36 Feet 26 ... 7. No. SEPARATION OF TURNS For best performance, separate all the straight portions DQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG WARNING - of power cord with UL listed transition duct. Attach ground wire of straight duct, including distance between last turn over 45º should present minimal resistance to ...
...end of each section of duct must point away from the dryer. • Do not assemble the ductwork with the opening pointed down. Properly secure power cord to the outer screws of 90º Elbows 0 1 2 4" Rigid Metal 43 Feet 33 Feet 24 Feet 2-1/2" Rigid Metal 36 Feet 26 ... 7. No. SEPARATION OF TURNS For best performance, separate all the straight portions DQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG WARNING - of power cord with UL listed transition duct. Attach ground wire of straight duct, including distance between last turn over 45º should present minimal resistance to ...