...freezing. All installations must be in accordance with a tube cutter and then use any other reverse osmosis water systems, follow the manufacturer's recommendations. Call a qualified plumber to correct water hammer before connecting the water line, make sure a saddle-type valve complies ... the shutoff valve on the amount of expensive water damage. WARNING - To determine how much tubing you need : measure the distance from GE SmartConnect™ Refrigerator tubing. • Shutoff valve to connect to minimize the risk of tubing you need . Do not cut square. ...
...freezing. All installations must be in accordance with a tube cutter and then use any other reverse osmosis water systems, follow the manufacturer's recommendations. Call a qualified plumber to correct water hammer before connecting the water line, make sure a saddle-type valve complies ... the shutoff valve on the amount of expensive water damage. WARNING - To determine how much tubing you need : measure the distance from GE SmartConnect™ Refrigerator tubing. • Shutoff valve to connect to minimize the risk of tubing you need . Do not cut square. ...
Owners Manual
Page 19
...). Average Product Water Concentration 1 cyst/L Contaminant reduction determined by NSF testing. Performance Data Sheet SmartWater Filtration System-GE® MWF Cartridge This system has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for unmetered usage) Standard No. 42: Aesthetic effects...
...). Average Product Water Concentration 1 cyst/L Contaminant reduction determined by NSF testing. Performance Data Sheet SmartWater Filtration System-GE® MWF Cartridge This system has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for unmetered usage) Standard No. 42: Aesthetic effects...
Owners Manual
Page 20
State of California Department of Public Health Water Treatment Device Certificate Number 05 - 1698 Date Issued: February 2, 2010 Trademark/Model Designation GE MWF Replacement Elements MWF Manufacturer: General Electric Company The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety ...
State of California Department of Public Health Water Treatment Device Certificate Number 05 - 1698 Date Issued: February 2, 2010 Trademark/Model Designation GE MWF Replacement Elements MWF Manufacturer: General Electric Company The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety ...