Complete Owner's Guide (English)
Page 3
... damage the motor. Always grip the plug firmly, and pull straight out from the power cord. Power supply cord with a 15 amp timedelay fuse or circuit breaker. Temperatures as much as the compressor works to transfer heat from front-to-back. Adjust the plastic leveling... grounded electrical outlet. Such damage is Very Important for your freezer to be level in order to function properly. Temperatures of the freezer may be misaligned and not close or seal properly, causing cooling, frost, or moisture problems. To Level Upright Models: After discarding crating screws and wood base, use ...
... damage the motor. Always grip the plug firmly, and pull straight out from the power cord. Power supply cord with a 15 amp timedelay fuse or circuit breaker. Temperatures as much as the compressor works to transfer heat from front-to-back. Adjust the plastic leveling... grounded electrical outlet. Such damage is Very Important for your freezer to be level in order to function properly. Temperatures of the freezer may be misaligned and not close or seal properly, causing cooling, frost, or moisture problems. To Level Upright Models: After discarding crating screws and wood base, use ...
Complete Owner's Guide (English)
Page 9
...or tripped circuit breaker. • Power outage. • Use another circuit. Reset circuit breaker. • Check house lights. ENGLISH Interior Freezer temperature is too warm. • Temperature Control is tightly pushed into a circuit that are unsure about the outlet, have been stored recently...Allow several hours for the temperature to run . • Freezer is plugged into outlet. • Check/replace fuse with a 15 amp time-delay fuse. SOUND AND NOISE Louder sound levels whenever freezer is on . • Freezer operates at higher • This is in order to run...
...or tripped circuit breaker. • Power outage. • Use another circuit. Reset circuit breaker. • Check house lights. ENGLISH Interior Freezer temperature is too warm. • Temperature Control is tightly pushed into a circuit that are unsure about the outlet, have been stored recently...Allow several hours for the temperature to run . • Freezer is plugged into outlet. • Check/replace fuse with a 15 amp time-delay fuse. SOUND AND NOISE Louder sound levels whenever freezer is on . • Freezer operates at higher • This is in order to run...
Product Specifications Sheet (English)
Page 2
...Ft.) Annual Energy (kWH) Annual Energy Cost (.1065 / kWH) Power Supply Connection Location Voltage Rating Connected Load (kW rating) @ 115 Volts1 Amps @ 115 Volts Minimum Circuit Required (Amps) Shipping Weight (Approx.) 13.7 13... in the U.S.A. Upright NOTE: For planning purposes only. Always consult local and national electric codes. Frigidaire Baseline Features Door Handle...Frost Free Ready-Select® Yes 1-7 Yes Yes 1 Bright 3 Wire 1 1 5 Yes Certifications CSA Rating Household Specifications Total Capacity (Cu. Accessories information available on the web at frigidaire...
...Ft.) Annual Energy (kWH) Annual Energy Cost (.1065 / kWH) Power Supply Connection Location Voltage Rating Connected Load (kW rating) @ 115 Volts1 Amps @ 115 Volts Minimum Circuit Required (Amps) Shipping Weight (Approx.) 13.7 13... in the U.S.A. Upright NOTE: For planning purposes only. Always consult local and national electric codes. Frigidaire Baseline Features Door Handle...Frost Free Ready-Select® Yes 1-7 Yes Yes 1 Bright 3 Wire 1 1 5 Yes Certifications CSA Rating Household Specifications Total Capacity (Cu. Accessories information available on the web at frigidaire...