Fluke 365 Clamp Meter Datasheet
Page 1
... Rugged meters where access is difficult The Fluke 365 is a new, innovative Fluke clamp meter, offering a thin, small jaw design that makes it easy to 200 A ac and dc with true-rms measurement. The detachable jaw on non-linear signals • 6000 Ω resistance measurement with continuity detection Features • Detachable jaw makes accessing wires and viewing the...
... Rugged meters where access is difficult The Fluke 365 is a new, innovative Fluke clamp meter, offering a thin, small jaw design that makes it easy to 200 A ac and dc with true-rms measurement. The detachable jaw on non-linear signals • 6000 Ω resistance measurement with continuity detection Features • Detachable jaw makes accessing wires and viewing the...
Fluke 365 Clamp Meter Users Manual
Page 1
Specifications are trademarks of their respective companies. All rights reserved. All product names are subject to change without notice. Printed in China. 365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 © 2010 Fluke Corporation.
Specifications are trademarks of their respective companies. All rights reserved. All product names are subject to change without notice. Printed in China. 365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 © 2010 Fluke Corporation.
Fluke 365 Clamp Meter Users Manual
Page 5
The Meter measures: • ac and dc current • ac and dc voltage • resistance • continuity The Meter ships with: • TL75 or TL175 test leads • carrying case • two AA batteries (installed) • magnetic hanger • 365 User Manual 1 The Fluke 365 is a true-rms hand-held, battery-operated clamp meter (the Meter) that features a detachable Jaw. Introduction Warning Read "Safety Information" before you use the Meter.
The Meter measures: • ac and dc current • ac and dc voltage • resistance • continuity The Meter ships with: • TL75 or TL175 test leads • carrying case • two AA batteries (installed) • magnetic hanger • 365 User Manual 1 The Fluke 365 is a true-rms hand-held, battery-operated clamp meter (the Meter) that features a detachable Jaw. Introduction Warning Read "Safety Information" before you use the Meter.
Fluke 365 Clamp Meter Users Manual
Page 7
Look for damaged insulation or exposed metal. When in doubt, have the Meter serviced. • Do not use only specified replacement parts. 3 Detachable Jaw True-rms Clamp Meter Safety Information Warning To prevent possible electrical shock or personal injury, follow these guidelines: • Use the Meter only ...
Look for damaged insulation or exposed metal. When in doubt, have the Meter serviced. • Do not use only specified replacement parts. 3 Detachable Jaw True-rms Clamp Meter Safety Information Warning To prevent possible electrical shock or personal injury, follow these guidelines: • Use the Meter only ...
Fluke 365 Clamp Meter Users Manual
Page 9
.... 5 See Manual. Risk of this product as unsorted municipal waste. Important information. Do not dispose of Danger. Double insulated Conforms to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. Symbol ... The Meter shuts down when the battery reaches 2.0 V. Symbols Symbol Battery. Low battery when shown. Detachable Jaw True-rms Clamp Meter Safety Information Caution To avoid possible damage to the Meter or to equipment under test: • Use ...
.... 5 See Manual. Risk of this product as unsorted municipal waste. Important information. Do not dispose of Danger. Double insulated Conforms to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. Symbol ... The Meter shuts down when the battery reaches 2.0 V. Symbols Symbol Battery. Low battery when shown. Detachable Jaw True-rms Clamp Meter Safety Information Caution To avoid possible damage to the Meter or to equipment under test: • Use ...
Fluke 365 Clamp Meter Users Manual
Page 11
The Meter Clamp Meter Detachable Jaw True-rms Clamp Meter The Meter 1 fig01.eps 7
The Meter Clamp Meter Detachable Jaw True-rms Clamp Meter The Meter 1 fig01.eps 7
Fluke 365 Clamp Meter Users Manual
Page 19
Detachable Jaw True-rms Clamp Meter Specifications Resolution 0.1 V Accuracy 1.5 % ±5 digits (45 - 400 Hz) DC Voltage Range 600.0 V Resolution 0.1 V Accuracy 1 % ±5 digits Resistance Range 600.0 Ω/6000 Ω Resolution 0.1 Ω/1 Ω Accuracy 1 % ±5 digits Mechanical Specifications Size (L x W x H 225 x 65 x 46 mm Weight 275 g (including batteries) Jaw Opening 18 mm Detachable Jaw Cable Length 900 mm 15
Detachable Jaw True-rms Clamp Meter Specifications Resolution 0.1 V Accuracy 1.5 % ±5 digits (45 - 400 Hz) DC Voltage Range 600.0 V Resolution 0.1 V Accuracy 1 % ±5 digits Resistance Range 600.0 Ω/6000 Ω Resolution 0.1 Ω/1 Ω Accuracy 1 % ±5 digits Mechanical Specifications Size (L x W x H 225 x 65 x 46 mm Weight 275 g (including batteries) Jaw Opening 18 mm Detachable Jaw Cable Length 900 mm 15
Fluke 365 Clamp Meter Users Manual
Page 21
Detachable Jaw True-rms Clamp Meter Specifications Safety Compliance ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 UL 61010-1:2004 EN/IEC 61010-1:2001 to 600V CAT III Pollution Degree 2 Agency Approvals Batteries 2 AA, NEDA 15A, IEC LR6 17
Detachable Jaw True-rms Clamp Meter Specifications Safety Compliance ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 UL 61010-1:2004 EN/IEC 61010-1:2001 to 600V CAT III Pollution Degree 2 Agency Approvals Batteries 2 AA, NEDA 15A, IEC LR6 17