Software Guide
Page 42
... Table 2-5 Designating VLANs and VLAN Ranges Example 10 5,10,15 10-50,500 Function Specifies VLAN 10 Specifies VLANs 5, 10, and 15 Specifies VLANs 10 through 50, inclusive, and VLAN 500 Specifying MAC Addresses Some commands require that is 32 bits, written in dotted decimal...do not insert spaces) to specify individual VLANs or a hyphen (-) between the VLAN numbers to designate VLANs and VLAN ranges. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 2-8 78-15486-01 To specify a list of VLANs, use IP host names instead of VLANs. ...
... Table 2-5 Designating VLANs and VLAN Ranges Example 10 5,10,15 10-50,500 Function Specifies VLAN 10 Specifies VLANs 5, 10, and 15 Specifies VLANs 10 through 50, inclusive, and VLAN 500 Specifying MAC Addresses Some commands require that is 32 bits, written in dotted decimal...do not insert spaces) to specify individual VLANs or a hyphen (-) between the VLAN numbers to designate VLANs and VLAN ranges. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 2-8 78-15486-01 To specify a list of VLANs, use IP host names instead of VLANs. ...
Software Guide
Page 69
... trunk link providing 2-Gbps bandwidth. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-5 Table 5-9 Oversubscribed Port Groupings for module WS-X4448-GB-RJ45. and trunk-capable NICs, share ...switching module (WS-X4418-GB) connecting multiple network servers and high-end workstations to transmit traffic simultaneously. Bundling multiple oversubscribed ports in another. Oversubscribed Gigabit Ethernet Example Figure 5-1 shows an example of four or eight oversubscribed ports has a buffer for each connected port (500...
... trunk link providing 2-Gbps bandwidth. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-5 Table 5-9 Oversubscribed Port Groupings for module WS-X4448-GB-RJ45. and trunk-capable NICs, share ...switching module (WS-X4418-GB) connecting multiple network servers and high-end workstations to transmit traffic simultaneously. Bundling multiple oversubscribed ports in another. Oversubscribed Gigabit Ethernet Example Figure 5-1 shows an example of four or eight oversubscribed ports has a buffer for each connected port (500...
Software Guide
Page 187
...in the management domain and how to make VLANs 2 to continue (y/n) [n]? y VTP domain Lab_Network modified Console> (enable) clear vtp pruneeligible 100-500 Vlans 1,100-500,1001-1023 will enable the pruning function in the management domain. Console> (enable) set vtp pruneeligible 250-255 Vlans 2-99,250-255,501-1000... configuration. Do you want to 99, 250-255, and 501-1000 pruning eligible on trunk 16/1 1-1005,1025-4094 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 9-11 indicates vtp domain mismatch # -
...in the management domain and how to make VLANs 2 to continue (y/n) [n]? y VTP domain Lab_Network modified Console> (enable) clear vtp pruneeligible 100-500 Vlans 1,100-500,1001-1023 will enable the pruning function in the management domain. Console> (enable) set vtp pruneeligible 250-255 Vlans 2-99,250-255,501-1000... configuration. Do you want to 99, 250-255, and 501-1000 pruning eligible on trunk 16/1 1-1005,1025-4094 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 9-11 indicates vtp domain mismatch # -
Software Guide
Page 213
... Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF Console> (enable) To modify the VLAN parameters on the Switch This example shows how to Development and verify the configuration:...}] [said said ] [mtu mtu] [translation vlan] Verify the VLAN configuration. Command set vlan 500 name Development Vlan 500 configuration successful Console> (enable) show vlan [vlan] 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-7
... Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF Console> (enable) To modify the VLAN parameters on the Switch This example shows how to Development and verify the configuration:...}] [said said ] [mtu mtu] [translation vlan] Verify the VLAN configuration. Command set vlan 500 name Development Vlan 500 configuration successful Console> (enable) show vlan [vlan] 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-7
Software Guide
Page 214
... 344 VLAN Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF Console> (enable) 10-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 set vlan 500-520 Vlan 500 configuration successful Vlan 501 configuration successful Vlan 502 configuration successful Vlan 503...
... 344 VLAN Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF Console> (enable) 10-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 set vlan 500-520 Vlan 500 configuration successful Vlan 501 configuration successful Vlan 502 configuration successful Vlan 503...
Software Guide
Page 216
... Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF 10-10 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Verify the port VLAN membership. Configuring VLANs on the Switch Chapter 10 Configuring VLANs This example shows how to change...
... Type SAID MTU Parent RingNo BrdgNo Stp BrdgMode Trans1 Trans2 500 enet 100500 1500 - - - - - 0 0 VLAN AREHops STEHops Backup CRF 10-10 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Verify the port VLAN membership. Configuring VLANs on the Switch Chapter 10 Configuring VLANs This example shows how to change...
Software Guide
Page 217
...in the network. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-11 In a network environment with non-Cisco devices that are connected to Cisco switches through 802.1Q trunks or traffic from a non-Cisco switch that has VLANs in the mapping ...1000 to ISL VLAN numbers. Chapter 10 Configuring VLANs Configuring VLANs on the Switch Console> (enable) show port 2/4 Port Name Status Vlan Level Duplex Speed Type 2/4 notconnect 500 normal auto auto 10/100BaseTX Port Security Secure-Src-Addr Last-Src-Addr Shutdown...
...in the network. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-11 In a network environment with non-Cisco devices that are connected to Cisco switches through 802.1Q trunks or traffic from a non-Cisco switch that has VLANs in the mapping ...1000 to ISL VLAN numbers. Chapter 10 Configuring VLANs Configuring VLANs on the Switch Console> (enable) show port 2/4 Port Name Status Vlan Level Duplex Speed Type 2/4 notconnect 500 normal auto auto 10/100BaseTX Port Security Secure-Src-Addr Last-Src-Addr Shutdown...
Software Guide
Page 219
... you want to continue (y/n) [n]?y Vlan 500 deleted Console> (enable) Configuring Auxiliary VLANs The following sections describe how to configure auxiliary VLANs to use with the VLAN (and thus, inactive) until you can connect a Cisco IP Phone to a Catalyst 4500 series switch. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-13...
... you want to continue (y/n) [n]?y Vlan 500 deleted Console> (enable) Configuring Auxiliary VLANs The following sections describe how to configure auxiliary VLANs to use with the VLAN (and thus, inactive) until you can connect a Cisco IP Phone to a Catalyst 4500 series switch. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 10-13...
Software Guide
Page 238
... allowed and active in management domain 4/1 2-6,10,20,50,100,152,200,300,400,500,521,524,570,776,801-802,850,917,999 11-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 When you disable VLAN 1 on a trunk...VLAN 1 on a trunk link and verify the configuration: Console> (enable) clear trunk 4/1 1 Removing Vlan(s) 1 from control protocols such as Cisco Discovery Protocol (CDP), VLAN Trunking Protocol (VTP), Port Aggregation Protocol (PAgP), Dynamic Trunking Protocol (DTP), and so forth. Because spanning tree applies...
... allowed and active in management domain 4/1 2-6,10,20,50,100,152,200,300,400,500,521,524,570,776,801-802,850,917,999 11-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 When you disable VLAN 1 on a trunk...VLAN 1 on a trunk link and verify the configuration: Console> (enable) clear trunk 4/1 1 Removing Vlan(s) 1 from control protocols such as Cisco Discovery Protocol (CDP), VLAN Trunking Protocol (VTP), Port Aggregation Protocol (PAgP), Dynamic Trunking Protocol (DTP), and so forth. Because spanning tree applies...
Software Guide
Page 239
...500,521,524,570,776,802,850,917,999 Console> (enable) Example VLAN Trunk Configurations The following sections contains examples of a VLAN trunk configurations: Note For examples of VLAN 1. Switch_A> (enable) set vlan 1 2/3-6 VLAN Mod/Ports 1 2/3-6 Switch_A> (enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches... Software Configuration Guide-Release 8.1 11-9 This VLAN is 802.1Q-capable.) Figure 11-1 shows two switches connected through four 1000BASE-SX Gigabit...
...500,521,524,570,776,802,850,917,999 Console> (enable) Example VLAN Trunk Configurations The following sections contains examples of a VLAN trunk configurations: Note For examples of VLAN 1. Switch_A> (enable) set vlan 1 2/3-6 VLAN Mod/Ports 1 2/3-6 Switch_A> (enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches... Software Configuration Guide-Release 8.1 11-9 This VLAN is 802.1Q-capable.) Figure 11-1 shows two switches connected through four 1000BASE-SX Gigabit...
Software Guide
Page 298
... statistics on the Layer 2-connected devices, GARP applications (for vlan : Total valid GMRP Packets Received:500 Join Empties:200 Join INs:250 15-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The value for leaveall must be greater than the value... to these rules, an error is returned. Set the leave timer to at least 1050 ms, and then set differently on the switch, perform this task in privileged mode: Task Display GMRP statistics. The more registered attributes there are set the join timer to the order...
... statistics on the Layer 2-connected devices, GARP applications (for vlan : Total valid GMRP Packets Received:500 Join Empties:200 Join INs:250 15-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The value for leaveall must be greater than the value... to these rules, an error is returned. Set the leave timer to at least 1050 ms, and then set differently on the switch, perform this task in privileged mode: Task Display GMRP statistics. The more registered attributes there are set the join timer to the order...
Software Guide
Page 377
...String Access-Type Number View public1 read-only public2 read-only 1 private1 read-write 2 1.3.6 secret1 read-write-all 500 1.3.6.1.4.1.9.9 Trap-Rec-Address Trap-Rec-Community Trap-Rec-Port Trap-Rec-Owner Trap-Rec-Index Console> (enable) Clearing ... in the vacmAccessTable and vacmSecurityToGroup tables are associated with new IP Address 172.20.60.100 mask 255.0.0.0 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-9 When you use a specific community string to the list. To specify an access number...
...String Access-Type Number View public1 read-only public2 read-only 1 private1 read-write 2 1.3.6 secret1 read-write-all 500 1.3.6.1.4.1.9.9 Trap-Rec-Address Trap-Rec-Community Trap-Rec-Port Trap-Rec-Owner Trap-Rec-Index Console> (enable) Clearing ... in the vacmAccessTable and vacmSecurityToGroup tables are associated with new IP Address 172.20.60.100 mask 255.0.0.0 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-9 When you use a specific community string to the list. To specify an access number...
Software Guide
Page 401
... to specify port 2/3 as an ingress source port for RSPAN VLAN 500 with port 2/34 as the reflector port: Console> (enable) set rspan source 2/3 500 reflector 2/34 filter 50,850 Rspan Type : Source Destination : - 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 26-11 VLAN DynCreated RSPAN 1 static disabled...
... to specify port 2/3 as an ingress source port for RSPAN VLAN 500 with port 2/34 as the reflector port: Console> (enable) set rspan source 2/3 500 reflector 2/34 filter 50,850 Rspan Type : Source Destination : - 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 26-11 VLAN DynCreated RSPAN 1 static disabled...
Software Guide
Page 402
... RSPAN destination port is connected to another device and reception of the destination switches participating in RSPAN. Verify the RSPAN configuration. Use this task in set rspan destination 3/1 500 Rspan Type : Destination Destination : Port 3/1 26-12 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 This example shows how to...
... RSPAN destination port is connected to another device and reception of the destination switches participating in RSPAN. Verify the RSPAN configuration. Use this task in set rspan destination 3/1 500 Rspan Type : Destination Destination : Port 3/1 26-12 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 This example shows how to...
Software Guide
Page 403
...switch for remote span. Command set rspan disable source [rspan_vlan | all] set rspan disable destination [mod_num/port_num | all] This example shows how to disable all enabled source sessions on the switch...: Console> (enable) set rspan disable source all This command will disable all source(s) on the switch...and destination sessions on the switch. y Disabled monitoring of...sessions on the switch: Console> (... traffic on the switch for all participating switches. Direction : -...Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ...
...switch for remote span. Command set rspan disable source [rspan_vlan | all] set rspan disable destination [mod_num/port_num | all] This example shows how to disable all enabled source sessions on the switch...: Console> (enable) set rspan disable source all This command will disable all source(s) on the switch...and destination sessions on the switch. y Disabled monitoring of...sessions on the switch: Console> (... traffic on the switch for all participating switches. Direction : -...Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ...
Software Guide
Page 495
... system. Console> (enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 30-51 Enable ...Accounting set to enable for connection events. Enabling Accounting To enable accounting on the switch. Console> (enable) Console> (enable) set accounting commands enable all events in...-only mode. Enable accounting for EXEC mode. Chapter 30 Configuring Switch Access Using AAA Configuring Accounting Note The amount of DRAM that...RADIUS and TACACS+ accounting on the switch, perform this task in stop -only tacacs...
... system. Console> (enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 30-51 Enable ...Accounting set to enable for connection events. Enabling Accounting To enable accounting on the switch. Console> (enable) Console> (enable) set accounting commands enable all events in...-only mode. Enable accounting for EXEC mode. Chapter 30 Configuring Switch Access Using AAA Configuring Accounting Note The amount of DRAM that...RADIUS and TACACS+ accounting on the switch, perform this task in stop -only tacacs...