...can be connected directly to change without notice. upper cabinet depth B. 30" (76.2 cm) min. Ref. or 50-amp power supply cord (pigtail). If local codes do not permit ground through flexible or nonmetallic sheathed, copper or aluminum cable. ... (61 cm) min. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS AER3311WA AER5522VA AER5523XA AER5524XA AER5822VA AER5823XA AER5830VA AER5844VA AER6011VA Electrical: Range must be connected to change materials and specifications without notice. CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for...
...can be connected directly to change without notice. upper cabinet depth B. 30" (76.2 cm) min. Ref. or 50-amp power supply cord (pigtail). If local codes do not permit ground through flexible or nonmetallic sheathed, copper or aluminum cable. ... (61 cm) min. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS AER3311WA AER5522VA AER5523XA AER5524XA AER5822VA AER5823XA AER5830VA AER5844VA AER6011VA Electrical: Range must be connected to change materials and specifications without notice. CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for...
Installation Instruction
Page 3
... or sustain other damage. Mobile home installations require: ■ When this range must be revised. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is located on the model/serial rating plate. This oven has been designed in a mobile home installation.
... or sustain other damage. Mobile home installations require: ■ When this range must be revised. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is located on the model/serial rating plate. This oven has been designed in a mobile home installation.
Installation Instruction
Page 5
... ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is located on the supply end. For 50-amp rated cord kits, use kits that the range can be connected directly to the circuit breaker box (or fused disconnect) through the neutral, use a 4-... cord rated at least 4 ft (1.22 m) long. 4-wire receptacle (14-50R) The minimum conductor sized for the copper 4-wire power cord are: 40-amp circuit 2 No.-8 conductors 1 No.-10 white neutral 1 No.-8 green grounding If connecting to the figures in a NEMA Type 10-50P plug on the oven...
... ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is located on the supply end. For 50-amp rated cord kits, use kits that the range can be connected directly to the circuit breaker box (or fused disconnect) through the neutral, use a 4-... cord rated at least 4 ft (1.22 m) long. 4-wire receptacle (14-50R) The minimum conductor sized for the copper 4-wire power cord are: 40-amp circuit 2 No.-8 conductors 1 No.-10 white neutral 1 No.-8 green grounding If connecting to the figures in a NEMA Type 10-50P plug on the oven...
Installation Instruction
Page 7
... positions marked on the bracket template. Remove template from the middle post of the terminal block. Fasten anti-tip bracket with a hammer. U.S.A. Use a new 40 amp power supply cord. Plug into holes with screws provided. Remove plastic tag holding three 10-32 hex nuts from floor. 6. Hex-head screws 7 Tap plastic...
... positions marked on the bracket template. Remove template from the middle post of the terminal block. Fasten anti-tip bracket with a hammer. U.S.A. Use a new 40 amp power supply cord. Plug into holes with screws provided. Remove plastic tag holding three 10-32 hex nuts from floor. 6. Hex-head screws 7 Tap plastic...
Installation Instruction
Page 8
...: box or fused Direct wire disconnect 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 3-wire connection: Power supply cord Style 2: Direct wire strain relief ■ Remove the knockout as needed for the power supply...the range. 4. A B C 5. Use a Phillips screwdriver to : 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord A A. Style 1: Power supply cord strain relief ■ Remove the knockout for the flexible conduit connection...
...: box or fused Direct wire disconnect 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 3-wire connection: Power supply cord Style 2: Direct wire strain relief ■ Remove the knockout as needed for the power supply...the range. 4. A B C 5. Use a Phillips screwdriver to : 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord A A. Style 1: Power supply cord strain relief ■ Remove the knockout for the flexible conduit connection...
Installation Instruction
Page 9
.... 5. Ground-link screw C. Line 2 (red) D D. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with ranges. 8. Connect line 2 (red) and line 1 (black) wires to neutral wire of range. A B 3-wire connection: ...of range. Ground-link screw D. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with...
.... 5. Ground-link screw C. Line 2 (red) D D. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with ranges. 8. Connect line 2 (red) and line 1 (black) wires to neutral wire of range. A B 3-wire connection: ...of range. Ground-link screw D. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with...