HP Workstations for Linux - User Guide
Page 6
... preload on HP Workstations. System RAM HP supports different amounts of total RAM in various HP Workstations based on the number of hardware DIMM slots and the capabilities of SLED and SLES on the xw4600 and 400, and from HP Workstation Support at http://www.hp.com/ support/linux_hardware_matrix. 2 Chapter 1 Linux on these Workstations. The total memory supported for each configuration is listed...
... preload on HP Workstations. System RAM HP supports different amounts of total RAM in various HP Workstations based on the number of hardware DIMM slots and the capabilities of SLED and SLES on the xw4600 and 400, and from HP Workstation Support at http://www.hp.com/ support/linux_hardware_matrix. 2 Chapter 1 Linux on these Workstations. The total memory supported for each configuration is listed...
HP Workstations for Linux - User Guide
Page 7
...Observed performance improvements depend on the 600 and 800 Workstations. NUMA requires that both processor sockets be populated, and installed memory should be balanced between both processors for details on dual-socket quad core 600 and 800 configurations. The 600 and 800 BIOS also provide a... such as optional devices. Select File > Save Changes and Exit. The ability to enter the BIOS Setup Utility. Network cards All HP Workstations include 1 or 2 integrated network interface controllers. Select Advanced > Processors. NUMA offers the potential to enter the BIOS Setup Utility. ...
...Observed performance improvements depend on the 600 and 800 Workstations. NUMA requires that both processor sockets be populated, and installed memory should be balanced between both processors for details on dual-socket quad core 600 and 800 configurations. The 600 and 800 BIOS also provide a... such as optional devices. Select File > Save Changes and Exit. The ability to enter the BIOS Setup Utility. Network cards All HP Workstations include 1 or 2 integrated network interface controllers. Select Advanced > Processors. NUMA offers the potential to enter the BIOS Setup Utility. ...
HP Workstations for Linux - User Guide
Page 19
... driver configuration mode that can be configured using the aticonfig application include: ● Xinerama- When enabled, it allows the X server to change core or memory clock values...command is installed in html format is issued: # aticonfig --initial HP recommends the interactive configuration utilities provided by ATI. ● ATI Overdrive-enables you to ... Screen # - When configured, it changes independent displays to perform the initial configuration of GDM , Gnome, and KDE display managers). ENWW AMD® / ATI graphics workstations 15 For more information ...
... driver configuration mode that can be configured using the aticonfig application include: ● Xinerama- When enabled, it allows the X server to change core or memory clock values...command is installed in html format is issued: # aticonfig --initial HP recommends the interactive configuration utilities provided by ATI. ● ATI Overdrive-enables you to ... Screen # - When configured, it changes independent displays to perform the initial configuration of GDM , Gnome, and KDE display managers). ENWW AMD® / ATI graphics workstations 15 For more information ...
HP Workstations for Linux - User Guide
Page 40
... CPU Utilization /c01117497 (AMD64/ EM64T) [AMD64/EM64T] Configured With 4GB to 4.5GB Of Memory May Panic During Boot /c01117503 (AMD64/ EM64T) Kernel Panic with Greater ...than or Equal to 4GB of Memory /c01131107 Creating X configs with ATI FireGL V3100 xw4200...X Hangs xw4300 xw4400 xw6400 xw8400 xw4200 xw4300 xw6200 xw8200 xw9300 xw6200 xw8200 xw4200 xw4300 xw6200 xw8200 xw4200 xw4300 xw6200 xw8200 xw4300 xw6400 xw8400 xw4200 xw4300 xw6200 xw8200 xw9300... xw6200 xw8200 xw4200 xw4200 36 Appendix A Appendix-HP release notes for Red Hat Enterprise Linux WS 3 Use the following ...
... CPU Utilization /c01117497 (AMD64/ EM64T) [AMD64/EM64T] Configured With 4GB to 4.5GB Of Memory May Panic During Boot /c01117503 (AMD64/ EM64T) Kernel Panic with Greater ...than or Equal to 4GB of Memory /c01131107 Creating X configs with ATI FireGL V3100 xw4200...X Hangs xw4300 xw4400 xw6400 xw8400 xw4200 xw4300 xw6200 xw8200 xw9300 xw6200 xw8200 xw4200 xw4300 xw6200 xw8200 xw4200 xw4300 xw6200 xw8200 xw4300 xw6400 xw8400 xw4200 xw4300 xw6200 xw8200 xw9300... xw6200 xw8200 xw4200 xw4200 36 Appendix A Appendix-HP release notes for Red Hat Enterprise Linux WS 3 Use the following ...
HP xw Workstation series Setup and Troubleshooting Guide
Page 32
... provides information on HP Desktop and Workstation systems. This diagnostic tool should be used to use for a specific system ● Easy to help determine hardware failures. uses similar user interface as an HTML file, including: ◦ System serial number ◦ System product number ◦ System BIOS revision ◦ Memory size and configuration ◦ Processor...
... provides information on HP Desktop and Workstation systems. This diagnostic tool should be used to use for a specific system ● Easy to help determine hardware failures. uses similar user interface as an HTML file, including: ◦ System serial number ◦ System product number ◦ System BIOS revision ◦ Memory size and configuration ◦ Processor...
HP xw Workstation series Setup and Troubleshooting Guide
Page 38
...: ● Number of loops to perform quickly while covering your system configuration. Selecting interactive tests provides the maximum control over a specified number of loops..., the test selection can not be executed, either the CD or USB flash drive and select HP Memory Test from the boot menu. Click this test selection offers all tests will run many times. ... picked to perform. By default, the three test modes do not reboot or power off your workstation, exit HP Vision Field Diagnostic, boot to select or unselect all available diagnostics. When choosing to run :...
...: ● Number of loops to perform quickly while covering your system configuration. Selecting interactive tests provides the maximum control over a specified number of loops..., the test selection can not be executed, either the CD or USB flash drive and select HP Memory Test from the boot menu. Click this test selection offers all tests will run many times. ... picked to perform. By default, the three test modes do not reboot or power off your workstation, exit HP Vision Field Diagnostic, boot to select or unselect all available diagnostics. When choosing to run :...
HP xw Workstation series Setup and Troubleshooting Guide
Page 48
... and Diagnostics CD (http://www.hp.com/support/ workstation_manuals). Manually turn on the external device is not turned workstation to verify the proper installation. Diagnostic...configuration conflicts with the workstation system. Table 5-2 Hardware installation problems Problem Probable Cause Recommended Solution Device is properly and securely connected and that pins in the wrong location. 2. 3. Ensure that the device is not seated or connected properly. Cables of the system. Reboot the workstation, and follow the instructions for four seconds. Wrong memory...
... and Diagnostics CD (http://www.hp.com/support/ workstation_manuals). Manually turn on the external device is not turned workstation to verify the proper installation. Diagnostic...configuration conflicts with the workstation system. Table 5-2 Hardware installation problems Problem Probable Cause Recommended Solution Device is properly and securely connected and that pins in the wrong location. 2. 3. Ensure that the device is not seated or connected properly. Cables of the system. Reboot the workstation, and follow the instructions for four seconds. Wrong memory...
HP xw Workstation series Setup and Troubleshooting Guide
Page 50
... audible codes (continued) Activity Possible cause Recommended action NOTE: Memory connector pin configurations vary, and can have either a 4-pin, 6-pin, or 8-pin configuration, depending on the system board. repeat this procedure until failure occurs. c. Contact HP for assistance. Contact HP for assistance. To prevent damage, disconnect the workstation power cord before you remove a component. 1. Pre-video...
... audible codes (continued) Activity Possible cause Recommended action NOTE: Memory connector pin configurations vary, and can have either a 4-pin, 6-pin, or 8-pin configuration, depending on the system board. repeat this procedure until failure occurs. c. Contact HP for assistance. Contact HP for assistance. To prevent damage, disconnect the workstation power cord before you remove a component. 1. Pre-video...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 11
... fan ENWW Item Description 10 Memory modules 11 Card guide/Front fan (fan is optional) 12 Graphics card 13 Optical drive* 14 PCI-E card Product features 1 Drive configurations can vary. For complete and current information on page 11 Product features Exploded view The following image shows a typical HP xw8400 Workstation. 1 Product overview This chapter presents...
... fan ENWW Item Description 10 Memory modules 11 Card guide/Front fan (fan is optional) 12 Graphics card 13 Optical drive* 14 PCI-E card Product features 1 Drive configurations can vary. For complete and current information on page 11 Product features Exploded view The following image shows a typical HP xw8400 Workstation. 1 Product overview This chapter presents...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 18
...hr. 8.2 BTU/hr. 14.1 BTU/hr. * Energy Star low energy mode. ** Heat dissipation calculation is based on power-saving features, see your workstation with the power button on the front panel, the power consumption falls below 10 W. To reach zero power consumption, unplug the... workstation from the power outlet or use a power strip with a switch. For additional information on measured watts, assuming the service level is attained for an example configuration: ● Two 3.73-GHz Xeon 5000 series dual-core processors ● Eight 1-GB, 667-MHz memory modules ● Two 160-GB SATA ...
...hr. 8.2 BTU/hr. 14.1 BTU/hr. * Energy Star low energy mode. ** Heat dissipation calculation is based on power-saving features, see your workstation with the power button on the front panel, the power consumption falls below 10 W. To reach zero power consumption, unplug the... workstation from the power outlet or use a power strip with a switch. For additional information on measured watts, assuming the service level is attained for an example configuration: ● Two 3.73-GHz Xeon 5000 series dual-core processors ● Eight 1-GB, 667-MHz memory modules ● Two 160-GB SATA ...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 21
See Power supply specifications on Linux-based workstations. In addition to these slot power specifications, the overall power consumption of the system (including I /O cards, processors, memory, and drives) must not exceed the maximum ratings of the system power supply. NOTE: Energy Star is ...W maximum from the system board connector, and 75 W maximum from the auxiliary graphics power connector. Energy Star compliance HP products purchased with the Energy Star configuration are set as graphics cards or optical drives, see the website of inactivity NOTE: If you have it enabled, ...
See Power supply specifications on Linux-based workstations. In addition to these slot power specifications, the overall power consumption of the system (including I /O cards, processors, memory, and drives) must not exceed the maximum ratings of the system power supply. NOTE: Energy Star is ...W maximum from the system board connector, and 75 W maximum from the auxiliary graphics power connector. Energy Star compliance HP products purchased with the Energy Star configuration are set as graphics cards or optical drives, see the website of inactivity NOTE: If you have it enabled, ...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 31
...error is entered. ● Select POST Messages Enabled or Disabled to change , or verify the system configuration, including settings for processor, graphics, memory, audio, storage, communications, and input devices. ● Modify the boot order of installed mass storage devices such ... identification number assigned by the system and functioning properly. ● Determine information about the operating environment of the workstation. ● Solve system configuration errors detected but not automatically fixed during POST, press any key (except F1 through F12). ● Establish ...
...error is entered. ● Select POST Messages Enabled or Disabled to change , or verify the system configuration, including settings for processor, graphics, memory, audio, storage, communications, and input devices. ● Modify the boot order of installed mass storage devices such ... identification number assigned by the system and functioning properly. ● Determine information about the operating environment of the workstation. ● Solve system configuration errors detected but not automatically fixed during POST, press any key (except F1 through F12). ● Establish ...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 77
... condition. Lay the workstation on its side with a diagnostics 2006 code for memory error (five beeps and blinks). ● If the BIOS can still be booted in memory, it up . 2. Installing a DIMM 1. Figure 4-17 Identifying memory slots The BIOS generates warnings/errors on invalid memory configurations. ● If... the green tab at the base of the plugged-in memory, the BIOS will halt with the system board facing up (2) to expose the memory modules. The system can find a valid memory configuration by disabling some of the memory fan (1) and lift it will do so and report ...
... condition. Lay the workstation on its side with a diagnostics 2006 code for memory error (five beeps and blinks). ● If the BIOS can still be booted in memory, it up . 2. Installing a DIMM 1. Figure 4-17 Identifying memory slots The BIOS generates warnings/errors on invalid memory configurations. ● If... the green tab at the base of the plugged-in memory, the BIOS will halt with the system board facing up (2) to expose the memory modules. The system can find a valid memory configuration by disabling some of the memory fan (1) and lift it will do so and report ...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 132
... the workstation. Table 5-14 Memory problems Problem Cause Solution System will not boot. Insufficient memory error during POST is defective. On some models, ECC and non-ECC memory modules ...ECC memory, HP does not support mixing ECC and nonECC memory. CD. New network card will not boot or does not function properly after installing additional memory modules. Solving memory ... installed. 122 Chapter 5 System diagnostics and troubleshooting ENWW Cannot connect to check memory configuration. System Installation. Flash the ROM. Otherwise, the system will not boot the...
... the workstation. Table 5-14 Memory problems Problem Cause Solution System will not boot. Insufficient memory error during POST is defective. On some models, ECC and non-ECC memory modules ...ECC memory, HP does not support mixing ECC and nonECC memory. CD. New network card will not boot or does not function properly after installing additional memory modules. Solving memory ... installed. 122 Chapter 5 System diagnostics and troubleshooting ENWW Cannot connect to check memory configuration. System Installation. Flash the ROM. Otherwise, the system will not boot the...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 138
... (AMB) IC. 1. If third-party memory has been added, test using HP memory only. 4. Verify proper memory module type. 201-Memory Error. Ensure that memory modules are installed correctly. 3. Replace the faulty memory modules. 6. Replace memory module if problem persists. 210-Incompatible memory modules (AMBs) detected. Verify proper memory module type. 2. memory configuration has changed from the workstation before reseating or replacing components...
... (AMB) IC. 1. If third-party memory has been added, test using HP memory only. 4. Verify proper memory module type. 201-Memory Error. Ensure that memory modules are installed correctly. 3. Replace the faulty memory modules. 6. Replace memory module if problem persists. 210-Incompatible memory modules (AMBs) detected. Verify proper memory module type. 2. memory configuration has changed from the workstation before reseating or replacing components...
HP xw8400 Workstation - Service and Technical Reference Guide
Page 139
... are either not all ECC, or not all memory modules are pressed. 3. The memory modules in its socket. 2. Replace memory module if problem persists. 212-Failed Processor. Refer to the system board even when the workstation is missing critical SPD information. Check the connector for the correct memory configurations and reseat the DIMMs accordingly. 301-Keyboard...
... are either not all ECC, or not all memory modules are pressed. 3. The memory modules in its socket. 2. Replace memory module if problem persists. 212-Failed Processor. Refer to the system board even when the workstation is missing critical SPD information. Check the connector for the correct memory configurations and reseat the DIMMs accordingly. 301-Keyboard...
HP xw8400 Service and Technical Reference Guide
Page 12
... current information on supported accessories and components, see http://partsurfer.hp.com. Item Description 10 Memory modules 11 Card guide/Front fan (fan is an example of an optical drive. Drive configurations can vary. Product features Exploded view The following image shows a typical HP xw8400 Workstation. Figure 1-1 Exploded view Table 1-1 Exploded view Item Description 1 PCI card...
... current information on supported accessories and components, see http://partsurfer.hp.com. Item Description 10 Memory modules 11 Card guide/Front fan (fan is an example of an optical drive. Drive configurations can vary. Product features Exploded view The following image shows a typical HP xw8400 Workstation. Figure 1-1 Exploded view Table 1-1 Exploded view Item Description 1 PCI card...
HP xw8400 Service and Technical Reference Guide
Page 80
... Removal and replacement procedures ENWW Installing a DIMM 1. Figure 4-15 Identifying memory slots The BIOS generates warnings/errors on invalid memory configurations. ● If there is no way to obtain a valid memory configuration by disabling some of size, from the system ( Pre-disassembly procedures ...-in memory, the BIOS will do so and report a warning during POST ("215-mismatched memory"). Disconnect power from smallest to expose the memory modules. Lay the workstation on page 60). The system can find a valid memory configuration by disabling some of the memory fan ...
... Removal and replacement procedures ENWW Installing a DIMM 1. Figure 4-15 Identifying memory slots The BIOS generates warnings/errors on invalid memory configurations. ● If there is no way to obtain a valid memory configuration by disabling some of size, from the system ( Pre-disassembly procedures ...-in memory, the BIOS will do so and report a warning during POST ("215-mismatched memory"). Disconnect power from smallest to expose the memory modules. Lay the workstation on page 60). The system can find a valid memory configuration by disabling some of the memory fan ...
HP xw8400 Service and Technical Reference Guide
Page 133
...memory with HP memory. 4. Processor is bad. 2. Reseat the processor. Run the Computer Setup utility and enable booting to check memory configuration. Memory configuration might not be set up correctly. memory requirements. You have been installed correctly and that the memory modules have run out of memory Check the memory...ROM or DVD devices are used. more memory to the drive. Reconnect power and data cables to the workstation. Table 5-14 Memory problems (continued) Problem Cause Solution Out of memory to Check the application documentation to see ...
...memory with HP memory. 4. Processor is bad. 2. Reseat the processor. Run the Computer Setup utility and enable booting to check memory configuration. Memory configuration might not be set up correctly. memory requirements. You have been installed correctly and that the memory modules have run out of memory Check the memory...ROM or DVD devices are used. more memory to the drive. Reconnect power and data cables to the workstation. Table 5-14 Memory problems (continued) Problem Cause Solution Out of memory to Check the application documentation to see ...
HP xw8400 Service and Technical Reference Guide
Page 138
...that the monitor is not connected or it might have 1. Reseat fan cable. Fan is attached and turned on page 67"Memory" for bent or missing pins. 3. Replace the fan. 512-Chassis fan not detected. Reseat chassis, rear chassis, or front chassis fan. ...Check the connector for the correct memory configurations and reseat the DIMMs accordingly. 301-Keyboard Error. Install latest version of the keys are assigned to restore image. 511-CPU Fan not detected. Reconnect keyboard with workstation powered off . 2. IRQ address conflicts with workstation powered off. 2. Reset the IRQ...
...that the monitor is not connected or it might have 1. Reseat fan cable. Fan is attached and turned on page 67"Memory" for bent or missing pins. 3. Replace the fan. 512-Chassis fan not detected. Reseat chassis, rear chassis, or front chassis fan. ...Check the connector for the correct memory configurations and reseat the DIMMs accordingly. 301-Keyboard Error. Install latest version of the keys are assigned to restore image. 511-CPU Fan not detected. Reconnect keyboard with workstation powered off . 2. IRQ address conflicts with workstation powered off. 2. Reset the IRQ...